manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Other
  8. •
  9. MadgeTech UltraShock-5 Specification sheet

MadgeTech UltraShock-5 Specification sheet

UltraShock
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60 °C (140 °F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1067035-00 REV 12 2014.11.25
Description UltraShock
Channels Shock (3 axes), Temperature, Humidity, Pressure
Range
*See Tables Below
Resolution
Accuracy
Sample Rate 512 Hz
Reading Rate 64 Hz up to 5 minutes
Memory 174,762/channel
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 7 days
Operating Environment -20 °C to +60 °C (-4 °F to +140 °F),
0 %RH to 95 %RH (non-condensing)
Material Anodized aluminum
Dimensions 3.5 in x 4.4 in x 1 in (89 mm x 112 mm x 26 mm)
Weight 12 oz (341 g)
Approvals CE
Shock Range +5 g +50 g +100 g +250 g
Accuracy +0.2 g +1.0 g +2.0 g +4.0 g
Resolution 0.01 g 0.03 g 0.05 g 0.2 g
*Shock Acceleration Range, Resolution and Accuracy
Product User Guide
UltraShock-5
Temperature, Humidity, Pressure, and Tri-axial +5g, Shock Data Logger
UltraShock-100
Temperature, Humidity, Pressure, and Tri-axial +100g, Shock Data Logger
UltraShock-50
Temperature, Humidity, Pressure, and Tri-axial +50g, Shock Data Logger
UltraShock-250
Temperature, Humidity, Pressure, and Tri-axial +250g, Shock Data Logger
Channel Temperature Humidity Pressure
Range -20 °C to +60 °C 0 %RH to 95 %RH 0 to 30 PSIA
Accuracy +0.5 °C +3 %RH +1 %FSR @ 25 °C
Resolution 0.1 °C 0.1 %RH 0.002 PSIA
*Acceleration Range, Resolution and Accuracy
Product Notes
Reading Intervals
The UltraShock measures pressure, temperature, humidity and tri-axial shock. When the
device is running, the shock parameter samples at 512 Hz and at the user specified reading
rate, the device writes the peak values (g-force) from the samples to memory.
For Example:
Pressure, temperature and humidity readings are taken at the user specified reading rate
up to a maximum of 2 seconds intervals.
Axis Orientation
When the UltraShock is laying flat, with the label facing up, the
x-axis indicates left to right direction and will read ~0 g when
still. The y-axis reads in a top to bottom direction and reads ~0 g
when still. The z-axis reads perpendicular to the other two axis,
and will read ~1 g when still.
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the software
The Software can be downloaded from the MadgeTech website at the following link: www.
madgetech.com/software-download. Double click the zipped dowloaded file and follow
the steps to complete the download
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
UltraShock Product User Guide
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the logger to the interface cable.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials: 3/32” HEX Driver (Allen Key) and a Replacement Battery (U9VL-J)
- Remove the cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely. Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The UltraShock standard calibration is performed at one temperature point at 25 °C, two
humidity points at 25 %RH and 75 %RH, two pressure points at 15 PSI and 27-30 PSI and
0 g for the x-axis, 0 g for the y-axis and 1 g for the z-axis.
Note: The shock parameters are not traceable to NIST.
Additional Services:
Custom calibration and verification point options available, please call for pricing.
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.
Sampled Data: Recorded Data:
Y-Axis
Z-Axis
X-Axis

This manual suits for next models

3

Other MadgeTech Other manuals

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech QuadTemp Specification sheet

MadgeTech

MadgeTech QuadTemp Specification sheet

MadgeTech TransiTempII-RH User manual

MadgeTech

MadgeTech TransiTempII-RH User manual

MadgeTech IFC200 User manual

MadgeTech

MadgeTech IFC200 User manual

MadgeTech QuadRT User manual

MadgeTech

MadgeTech QuadRT User manual

MadgeTech TransiTemp-EC User manual

MadgeTech

MadgeTech TransiTemp-EC User manual

MadgeTech PRHTemp101A User manual

MadgeTech

MadgeTech PRHTemp101A User manual

MadgeTech RHTemp101A User manual

MadgeTech

MadgeTech RHTemp101A User manual

MadgeTech DHS User manual

MadgeTech

MadgeTech DHS User manual

MadgeTech HiTemp140-2 Specification sheet

MadgeTech

MadgeTech HiTemp140-2 Specification sheet

MadgeTech IFC300 User manual

MadgeTech

MadgeTech IFC300 User manual

MadgeTech TempRetrieverRH Specification sheet

MadgeTech

MadgeTech TempRetrieverRH Specification sheet

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech Element CO2 Specification sheet

MadgeTech

MadgeTech Element CO2 Specification sheet

MadgeTech HiTemp140-M12 User manual

MadgeTech

MadgeTech HiTemp140-M12 User manual

Popular Other manuals by other brands

Aqua Medic Mistral 50 ECO Operation manual

Aqua Medic

Aqua Medic Mistral 50 ECO Operation manual

caenrfid qIDminiNF R1170INF Technical information manual

caenrfid

caenrfid qIDminiNF R1170INF Technical information manual

Glas Craft GUARDIAN A6-6000 user manual

Glas Craft

Glas Craft GUARDIAN A6-6000 user manual

Alfalaval Toftejorg TZ-74 instruction manual

Alfalaval

Alfalaval Toftejorg TZ-74 instruction manual

All Pond Solutions FW-7 manual

All Pond Solutions

All Pond Solutions FW-7 manual

Elite 01332 instruction manual

Elite

Elite 01332 instruction manual

PULSE+ MEGAMOUTH MP3 MKII user guide

PULSE+

PULSE+ MEGAMOUTH MP3 MKII user guide

IDTECH vivopay kiosk iii user manual

IDTECH

IDTECH vivopay kiosk iii user manual

Mark beam 195 user manual

Mark

Mark beam 195 user manual

Reelcraft Industries, Inc. SD13050 OLP118 operating instructions

Reelcraft Industries, Inc.

Reelcraft Industries, Inc. SD13050 OLP118 operating instructions

Central Pneumatic 91064 Assembly and operating instructions

Central Pneumatic

Central Pneumatic 91064 Assembly and operating instructions

ALLPOWER APG3201 owner's manual

ALLPOWER

ALLPOWER APG3201 owner's manual

Aqua Medic CO2 reactor M Operation manual

Aqua Medic

Aqua Medic CO2 reactor M Operation manual

Silk'n Makeup Mirror M60033AB00-NL user manual

Silk'n

Silk'n Makeup Mirror M60033AB00-NL user manual

BlackBull HBJ4 Assembly & operating instructions

BlackBull

BlackBull HBJ4 Assembly & operating instructions

Easy@Home MD-818 user manual

Easy@Home

Easy@Home MD-818 user manual

Aqua Medic midiflotor Operation manual

Aqua Medic

Aqua Medic midiflotor Operation manual

Champion 100299 Owner's manual & operating instructions

Champion

Champion 100299 Owner's manual & operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.