manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Other
  8. •
  9. MadgeTech TransiTempII-RH User manual

MadgeTech TransiTempII-RH User manual

TransiTempII-RH
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 100 °C (212 °F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1141035-00 REV 11 2014.11.26
TransiTempII-RH
Splashproof Temperature and Humidity
Data Logger
Description TransiTempII-RH
Sensor Semiconductor
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.1 °C (0.18 °F)
Temperature Accuracy +0.5 °C (+0.9 °F)
Humidity Sensor Capacitive Polymer
Humidity Range 0 %RH to 95 %RH
Humidity Resolution 0.1 %RH
Humidity Accuracy +5 %RH
Memory 16,383/channel
Reading Rate 5 seconds up to 30 minutes
RH Units %RH, dew pt., water vapor concentration (mg/ml)
Alarm Temperature
LED Indicator Red, Yellow & Green
Required Interface Package IFC300
Baud Rate 38,400
Typical Battery Life 1 year
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F),
0 %RH to 95 %RH (non-condensing)
Submergible Splash Resistant (IP64)
Material ABS plastic, polycarbonate label
Dimensions 3.3 in x 2.1 in x 0.4 in (83 mm x 54 mm x 11 mm)
Weight 1.4 oz (40 g)
Approvals CE
Product User Guide
Product Notes
Manual Start
To start the data logger with the
Manual Start option, use the
magnetic wand provided (in the IFC300) to touch the start/mark switch.
(manual start is defaulted to a 10 minute reading rate) The reading rate can
be modified in the MadgeTech 4 Software. Connect the data logger, touch
the wand to the start/mark switch, the green LED (OK) will blink 5 times
followed by the yellow LED (WARN) and the red LED (ALARM), indicating
the device is recording. The logger must be manually stopped through the
MadgeTech 4 software.
Marking Feature
A date and time stamp may be placed in the recorded data, by touching
the magnetic wand to the start/mark switch. The marking feature may be
configured to clear the alarm and warn indicators, while the logger is still active.
Submergibility
The TransiTempII-RH is splash resistant, rated IP64.
LEDs
Green: Blinks to indicate safe conditions during acquisition.
Yellow: Blinks to indicate warning limits have been exceeded.
Red: Blinks to indicate alarm criteria (limits/delay) have been exceeded
Alarm Settings
To change the settings for the temperature alarm;
- Select Alarm Settings from the Device menu in the MadgeTech software. A window will
appear allowing the customer to set the high and low temperature alarms.
- Press Change to edit the values.
- Check Enable Alarm Settings to enable the feature. The values can be entered in the
field manually or by using the scroll bars.
- Click Save to save the changes. To clear an active alarm, press Clear Alarm.
Installation Guide
Installing the Interface cable
- IFC300
Refer to the “Quick Start Guide” included in the package.
Installing the software
Software can also be downloaded from the MadgeTech website at the following link: www.
madgetech.com/software-download. Double click the zipped download file and follow the
steps to finsh downloading .
Connecting the data logger
Product User Guide
TransiTempII-RH
- Once the software is installed and running, plug the interface cable into the docking
station.
- Place the TransiTempII-RH data logger into the IFC300 dock.
- In the MadgeTech 4 software the TransiTempII-RH will automatically appear under
Connected Devices.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Select the device from the connected devices list.
- On the Device Ribbon tab, Control Group, select Custom Start.
- Choose the desired start parameters and Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- When the device is succesfully started, the status will display Running.
- Remove the data logger from the IFC300 docking station and place it in the environment
to be measured.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Device Maintenance
Battery Replacement
The TransiTempII-RH must be sent to MadgeTech for battery replacement.
Recalibration
The TransiTempII-RH standard calibration is one point at 25 °C and two points at 25 %RH
and 75 %RH.
Custom calibration and verification point options available, please call for pricing.
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.
To start the device, hold
the magnetic wand over
the start/mark switch. (Also
indicated below)
Close-up of the
start/mark switch

Other MadgeTech Other manuals

MadgeTech RHTemp101A User manual

MadgeTech

MadgeTech RHTemp101A User manual

MadgeTech DHS User manual

MadgeTech

MadgeTech DHS User manual

MadgeTech PRHTemp101A User manual

MadgeTech

MadgeTech PRHTemp101A User manual

MadgeTech TransiTemp-EC User manual

MadgeTech

MadgeTech TransiTemp-EC User manual

MadgeTech QuadTemp Specification sheet

MadgeTech

MadgeTech QuadTemp Specification sheet

MadgeTech IFC300 User manual

MadgeTech

MadgeTech IFC300 User manual

MadgeTech HiTemp140-2 Specification sheet

MadgeTech

MadgeTech HiTemp140-2 Specification sheet

MadgeTech TempRetrieverRH Specification sheet

MadgeTech

MadgeTech TempRetrieverRH Specification sheet

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech UltraShock-5 Specification sheet

MadgeTech

MadgeTech UltraShock-5 Specification sheet

MadgeTech Element CO2 Specification sheet

MadgeTech

MadgeTech Element CO2 Specification sheet

MadgeTech IFC200 User manual

MadgeTech

MadgeTech IFC200 User manual

MadgeTech HiTemp140-M12 User manual

MadgeTech

MadgeTech HiTemp140-M12 User manual

MadgeTech QuadRT User manual

MadgeTech

MadgeTech QuadRT User manual

Popular Other manuals by other brands

Daewoo BM090 manual

Daewoo

Daewoo BM090 manual

Griven DC 36W 350mA DMX VST operating instructions

Griven

Griven DC 36W 350mA DMX VST operating instructions

fadini BARRI 88 Fitting instructions

fadini

fadini BARRI 88 Fitting instructions

Leclerc Looms ARTISAT 36 inch Assembly manual

Leclerc Looms

Leclerc Looms ARTISAT 36 inch Assembly manual

Plasma Air PlasmaPURE AutoClean 1500 Installation, operation & maintenance manual

Plasma Air

Plasma Air PlasmaPURE AutoClean 1500 Installation, operation & maintenance manual

Ferplast CAPRI JUNIOR user manual

Ferplast

Ferplast CAPRI JUNIOR user manual

Autonics krn100 series instruction manual

Autonics

Autonics krn100 series instruction manual

Dickson PR125 operating instructions

Dickson

Dickson PR125 operating instructions

Yamaha MSH-9150 owner's manual

Yamaha

Yamaha MSH-9150 owner's manual

PPE Stage 3 installation guide

PPE

PPE Stage 3 installation guide

HTC Vive Enterprise user manual

HTC

HTC Vive Enterprise user manual

Gorgy Timing LEDI NETWORK TDS V1 user manual

Gorgy Timing

Gorgy Timing LEDI NETWORK TDS V1 user manual

Keithley 1801 instruction manual

Keithley

Keithley 1801 instruction manual

iCarsoft MB II user manual

iCarsoft

iCarsoft MB II user manual

JUWEL Aquarium VIO 40 instruction manual

JUWEL Aquarium

JUWEL Aquarium VIO 40 instruction manual

Martin Audio Wavefront W8CT manual

Martin Audio

Martin Audio Wavefront W8CT manual

Elitech RC-4 quick start guide

Elitech

Elitech RC-4 quick start guide

Paradyne 3162 quick reference

Paradyne

Paradyne 3162 quick reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.