Capacitance
Range Resolution Accuracy
5μF 0.001μF ± (3.0% of rdg + 15 dgts)
50μF 0.01μF ± (3.0% of rdg + 5 dgts)
500μF 0.1μF
5mF 0.001mF ± (5.0% of rdg + 20 dgts)
Overload Protection: 600V DC or AC rms.
Temperature
Range Resolution Accuracy
-35°C to 0°C
0.1°C
± (2.0% of rdg + 3°C)
0°C to 300°C ± (1.0% of rdg + 1°C)
300°C to 500°C ± (2.0% of rdg + 3°C)
-30°F to 32°F
0.1°F
± (2.0% of rdg + 6°F)
32°F to 572°F ± (1.0 % of rdg + 2°F)
572°F to 932°F ± (2.0% of rdg + 6°F)
Overload Protection: 30V DC or AC rms.
Frequency
Frequency measurement using AC current range
Range Resolution Accuracy
30Hz to 400Hz 0.1Hz ± (0.1% of rdg + 5 dgts)
Input sensitivity > 10A AC rms.
Maximum input current: 200A AC rms
Frequency measurement using Hz/% ranges.
Range Resolution Accuracy
500Hz 0.1Hz
± (0.1% of rdg + 5 dgts)
5kHz 0.001kHz
50kHz 0.01kHz
500kHz 0.1kHz
1MHz 0.001MHz
Sensitivity (10Hz to 1MHz): >3.5V AC rms.
ET5 instructions rev2.indd 2 09/07/2013 12:39:18
Minimum pulse width: >1μs.
Duty cycle limits: >30% and <70%.
Overload protection: 600V DC or AC rms.
Duty Cycle
Range Frequency
Range
Resolution Pulse Width Accuracy (5V Logic)
5% to 95% 40Hz to 20kHz 0.1% >10 us ±(2.0% rdg + 10 dgts)
Overload protection: 600VDC or AC rms.
Continuity
Range Resolution Response time Accuracy
500:0.1:100ms <30:
Overload protection: 600V DC or AC rms
Diode Test
Range Resolution Test current Open circuit
voltage
Accuracy
2V 1mV 0.8mA approx. 3.2V DC approx. ± (1.5% rdg + 5 dgts)
Overload protection: 600V DC or AC rms
Non-Contact Voltage Indicator
Range: 70V to 600V (50Hz to 60Hz)
GENERAL
Display: Liquid crystal display with a maximum reading of 5000 digits, dual
display
Polarity: Automatic, positive implied, ‘-‘ for negative polarity indication.
Overrange: (OL) or (-OL) is displayed
Zero: Automatic
Low battery indication: The battery capacity is shown by the symbols on
the LCD. If the symbol is flashing followed by a LO.Bt display, the battery
needs replacing as measurement accuracy can no longer be guaranteed
Measurement rate: 3.3 times per second, nominal
ET5 instructions rev2.indd 5 09/07/2013 12:39:17
Auto power off: After approx. 30 minutes
Power: 9V, PP3 alkaline battery (IEC 6LR61, NEDA 1604A).
Battery life: 50 hours typical with carbon zinc
100 hours typical with alkaline
Fork maximum conductor size: 15mm diameter
Dimensions: 202.5mm (L) x 51mm (W) x 44mm (D)
Weight: Approx. 200g including battery
Includes: TL17 test leads, 9V battery, K type thermocouple and instructions
ENVIRONMENTAL
Operating environment: 0°C to 40°C, <70% RH
Storage temperature: -20°C to 60°C, 0 to 80% RH
Altitude: Up to 2000m.
SAFETY
Conforms to BS EN 61010-1, BS EN 61010-2-032, CAT III 600V
Class II, Double Insulation
Pollution Degree: 2, indoor use
EMC
Conforms to BS EN 61326-1.
TL17 TEST LEADS SPECIFICATION
Maximum voltage: 1000V AC/DC
Maximum current: 10A continuous
Connectors: 4mm banana plugs
Conforms to BS EN 61010-031
Insulated end cap fitted: CAT IV 600V, CAT III 1000V, 10A
Insulated end cap removed: CAT II 1000V, 10A.
Class II, Double Insulation
Pollution degree 2
ET5 instructions rev2.indd 4 09/07/2013 12:39:17
Check out what else you can get from Martindale:
Martindale Electric Company Limited
Metrohm House, Imperial Park, Imperial Way,
Watford, Hertfordshire, WD24 4PP, UK
Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900
Website: www.martindale-electric.co.uk
© 2016Martindale Electric Company Ltd.
Registered in England No. 3387451. E. & O.E. Document Rev2 LITET5
•17th Edition Testers
•Accessories
•Calibration Equipment
•Continuity Testers
•Electricians’ Kits
•Environmental Products
•Full Calibration & Repair Service
•Fuse Finders
•Digital Clamp Meters
•Digital Multimeters
•Labels
•Microwave Leakage Detectors
•Motor Maintenance Equipment
•Multifunction Testers
•Non-trip Loop Testers
•Pat Testers & Accessories
•Phase Rotation Testers
•Proving Units
•Socket Testers
•Thermometers & Probes
•Test Leads
•Voltage Indicators
•Specialist Metrohm Testers (4 & 5kV)
•Specialist Drummond Testers
ET5 instructions rev2.indd 1 09/07/2013 12:38:51