SPECIFICATION
File Name:RST-7K5-HV-SPEC
2023-08-17
MODEL
CURRENT RANGE
RATED POWER
FULL POWER VOLTAGE RANGE
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
FREQUENCY RANGE
EFFICIENCY (Typ.)
Note.7
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
3000ms, 200ms at full load
47 ~ 63Hz
3 3W Y 340~530VACψψ/
△
196~305VAC or 3 4W/
100 ~ 107% of rated current
Protection type : Constant current limiting, unit will shutdown after 5 sec. re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
RST-7K5: RST-7K5-L:
12Kg; 1pcs/13Kg/1.25CUFT 12Kg; 1pcs/13Kg/1.05CUFT
234.5K hrs min. Telcordia SR-332 (Bellcore) ; 27.1K hrs min. MIL-HDBK-217F (25 )℃
94%
145 ~ 166V
95%
273 ~ 312V
95%
420 ~ 480V
±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0%
1Vp-p 2Vp-p 4Vp-p
90 ~ 138V 170 ~ 260V 260 ~ 400V
115V 230V 380V
65A 32.4A 19.77A
0 ~ 65A 0 ~ 34.5A 0 ~ 22.5A
7475W
115 ~ 138V 216 ~ 260V 334 ~ 400V
7452W 7515W
RST-7K5-115 RST-7K5-230 RST-7K5-380
POWER FACTOR (Typ.) ≧0.98/230VAC(400VAC)/
≧0.97/277VAC(480VAC) at full load
SAFETY STANDARDS
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
WITHSTAND VOLTAGE
Note.4
ISOLATION RESISTANCE Note.4
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 8)
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
BS EN/EN55024 , BS EN/EN61204-3, BS EN/EN61000-6-2
Standard
Standard
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class A
Class A
-----
-----
EMC IMMUNITY
EMC EMISSION
ALARM SIGNAL OUTPUT
REMOTE ON-OFF CONTROL Please refer to the Function Manual
AC fail, DC OK, fan fail, OTP. Please refer to the Function Manual
CURRENT SHARING Up to 4 units. Please refer to the Function Manual
OUTPUT VOLTAGE PROGRAMMABLE
Can be adjusted via built-in potentiometer
Adjustment of output voltage is allowable between 1 ~ 120% of nominal output voltage. Please refer to the PV curve Function Manual
Adjustment of constant current level is allowable between 20 ~ 100% of rated current. Please refer to the Function Manual
CONSTANT CURRENT LEVEL PROGRAMMABLE
Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line
7.5KW Input With High Voltage Output3Wψ4
1. All parameters NOT specially mentioned are measured at △230VAC(Y 400VAC) input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.includes set up tolerance,
4. During withstand voltage and isolation resistance testing, the screw A shall be temporarily removed, and shall be installed back after the testing.
5. Derating may be needed under low input voltages. Please check the for more details.derating curve
6.
If use PV signal to adjust Vo, under creatin operation conditions, ripple noise of Vo might go over rating defined in this specification.
7. The efficiency is measured at : 230VAC/Y: 400VAC input. The efficiency level is measured at output voltage 115V(115V model)/230V(230V model)/△
380V(380V model).
8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.600 900 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10. sAn unstable O/P voltage is expected in the first 300m after power on. A minimum load of 5% is suggested if fast load change is required at power on
phase.
※ Product Liability Disclaimer For detailed information, please refer to :https://www.meanwell.com/serviceDisclaimer.aspx
RST-7K5-HV series
16ms 230VAC/400VAC at 75% load 10ms / 230VAC/400VAC at full load
22.5A/230VAC( / ) 13A/400VAC( / Y)
3 3-wire 3 4-wireψψ
△
75A/230VAC( / ) 50A/400VAC( / Y)
3 3-wire 3 4-wireψψ
△
<3.5mA/Y 53 VAC <10mA 305VAC0/△
I/P-O/P:4.3KVDC I/P-FG:2.8KVDC O/P-FG:2.8KVDC
RST-7K5: 460*211*83.5mm (L*W*H) RST-7K5-L: 460*216*83.5mm (L*W*H)
UL62368-1, CAN/CSA C22.2 , TUV BS EN/EN62368-1, EAC TP TC 004 approvedNo. 62368-1
BS EN/ BS EN/EN55032 (CISPR32) / EN55011 (CISPR11)
BS EN/ BS EN/EN55032 (CISPR32) / EN55011 (CISPR11)
BS EN/EN61000-3-2
BS EN/EN61000-3-3
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-4
BS EN/EN61000-4-5
BS EN/EN61000-4-6
BS EN/EN61000-4-8
BS EN/EN61000-4-11
DC VOLTAGE (factory default)
CURRENT (factory default)
VOLTAGE RANGE