7
SAFETY &
EMC
(Note.9)
OTHERS
NOTE
SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, approved; design refers to BS EN/EN61558-1,EAC TP TC 004
BS EN/EN60335-1(by request)
OVC I/P-O/P: 6KVDC I/P-FG:4KVDC O/P-FG:4KVDCⅢ
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25 / 70%RH℃
478K hrs min. Telcordia SR-332 (Bellcore) ; 44.8K hrs min. MIL-HDBK-217F (25 )℃
375*280*88mm (L*W*H), without mounting plate
14Kg; 1pcs/14Kg/1.36CUFT
BS EN/EN55024, BS EN/EN61000-6-2
Parameter
Parameter
Standard
Standard
BS EN/EN55032 (CISPR32)
BS EN/EN61000-4-2
BS EN/EN55032 (CISPR32)
BS EN/EN61000-4-3
BS EN/EN61000-3-2
BS EN/EN61000-4-4
BS EN/EN61000-4-6
BS EN/EN61000-4-11
BS EN/EN61000-3-3
BS EN/EN61000-6-2
BS EN/EN61000-4-8
Test Level / Note
Test Level / Note
Class B
Level 3, 8KV air ; Level 2, 4KV contact
Class A
Level 3
Level 3
Class A
Level 3
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
-----
2KV/Line-Line 4KV/Line-Earth
Level 4
Conducted
ESD
Radiated
Radiated
Harmonic Current
EFT / Burst
Conducted
Voltage Dips and Interruptions
Voltage Flicker
Surge
Magnetic Field
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of am ient temperature.℃
2. Ripple & noise are measured at 20MHz of andwidth y using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. This is Mean Well's suggested range. Please consult your attery manufacturer for their suggestions a out maximum charging current limitation.
4. Tolerance : line regulation and load regulation.includes set up tolerance,
5. Derating may e needed under low input voltages. Please check the for more details.derating curve
6. SVR function is disa led during PV/PC programming operation.
7. During withstandards voltage and isolation resistance testing, the screw "A" shall e temporarily removed, and shall e istalled ack after the testing.
8. The power supply is considered a component which will e installed into a final equipment. All the EMC tests are een executed y mounting the unit on
1100 650 For guidance on how a mm* mm metal plate with 1mm of thickness. The final equipment must e re-confirmed that it still meets EMC directives.
to perform these EMC tests, please refer to EMI testing of component power supplies. (as availa le on http://www.meanwell.com)
9. The am ient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10. This series meets the typical life expectancy of > 55,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is a out 80 or less. ℃
※: Product Lia ility Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
EMC EMISSION
EMC IMMUNITY
Note.7
Note.7
2