p: 0800 503 335 | w: www.southernhospitality.co.nz
e: online@southernhospitality.co.nz
SOUTHERN
HOSPITALITY
DISTRIBUTED BY:
6
EEH2
EHW-CM
Operation Manual
6. Adjusting the Display Brightness
7. Check Weighing (Data Compare) Mode
1. From normal weighing mode, press the ON//ZERO key for 3 seconds.
2. The default setting of LU-1 will be displayed. Press and release the SET/0~9 key to cycle
through LU-0 to LU-3 where LU-3 is the brightest setting. LU-1 is recommended to maximise
battery life.
3. Press the TARE key to select and return to normal weighing mode.
The check weighing or data compare function allows the user to input a pre-set range and
the display will indicate whether the weighed value is within that range or indicate if it is too
high or too low.
1. From normal weighing mode, press the SET/0~9 key for 3 seconds to enter Setup mode.
2. Press and release the SET/0~9 key to cycle through the parameters until rAngE is shown.
Press the TARE key to confirm.
3. Press the SET/0~9 key until ON is shown. Press the TARE key to confirm.
4. The previously used lower limit value will be displayed with the first digit flashing and
the Under light flashing. Enter the lower limit of the check weighing range using the
SET/0~9 key to increase the flashing digit and the TARE key to accept a digit and move
to the next position.
Note: The decimal does not appear on the display when entering limit values, but the
value should be entered as if it did appear. For example: A lower limit of 2.55
pounds should be entered as 02550 on the display.
5. The previously used upper limit will be displayed with the first digit flashing and
the Over light flashing. Enter the upper limit of the check weighing range using the
SET/0~9 key to increase the flashing digit and the TARE key to accept a digit and move
to the next position. After the last digit has been entered, the scale will return to weighing
mode and check weighing may begin.
Note: The upper limit must be larger that the lower limit. If it is not oFF will be displayed
and the scale will return to the normal weighing mode and check weighing will
deactivated.
6. Place objects on the scale platform. The weight will be shown on the display. If the
weight is within the specified range, the Accept light will be lit and an audible tone will
sound. If the value is outside the specified range, the Over or Under light will be lit up
with no audible sound.
Note: The audible tone parameter can be changed from its default within User Setup
mode.
Note: If the weight has not been stabilised, no lights will be lit up.
7. To turn o the check weighing function, enter Setup mode following Steps 1–3 above
and change the setting to oFF