4=continuously output gross, tare, net weight, unit and status data,
data has not been received;
5=output weight, unit and status data one time when scale becomes
stable;
6=output gross, tare, net weight, unit and status data one time when
scale becomes stable;
7=Command –response mode.
U6 3
Baud rate for Serial communication:
0=1200,1=2400,2=4800;3=9600;4=19200 3
U7 0
Serial communication data format:
0=8N1;1=7O1;2=7E1 0
4. More Information for User Parameters Setting:
U5 to set serial communication output format:
(1). U5=0: No serial communication function. It will not transmit or receive any data even if the scale is
installed with serial communication hardware. Serial communication function can be only activated when
the scale is in normal weighing mode.
(2). U5=1: Press PRINT key, the scale will output the current stable weight, weight unit, and current Status
data ; it does not received any data. The output format is as below:
<LF>< weight reading, minus, decimal point, weight unit><CR><LF>H1H2H3 <CR><ETX>
(3). U5=2: Press PRINT key, the scale will output the data of stable gross, tare, net weight, weight unit and
current status data. The format is as follows:
<LF><Gross: reading, minus, decimal point, unit><CR>
<LF><Tare: reading, decimal point, unit><CR>
<LF><Net: reading, minus, decimal point, unit><CR>
<LF>H1H2H3<CR><ETX>
The number of bytes used:
Weight reading ----------------------- 8bytes;
Minus ----------------------------------1byte;
Decimal point -------------------------1byte;
Weight unit ----------------------------2 or 5 bytes;
Current status (H1.H2.H3) --------- 3bytes
(4). U5=3: Continuously output of the current displayed reading, weight unit and current status data, it does
not receive any data. The output format is same as U5=1.
(5). U5=4: Continuously output of the current gross weight, tare weight, net weight data, weight unit and
current status data, it does not receive any data. The output format is same as U5=2.
(6). U5=5: When the scale is stable, it will output the current displayed reading ,weight unit, and current
status data automatically one time, it does not receive any data. The output format is same as U5=1.
(7). U5=6: When the scale is stable, it will output the current gross weight, tare weight, net weight unit and
current status data automatically one time, it does not receive any data. The output format is same as
U5=2.
(8). U5=7: Bio-Serial Communication: after receiving an available command, the indicator will send out the
corresponding messages.
5. More Details About Serial Communication
PS‐102www.measuretek.net.11