15
Tank [1] with pump [2], hose [4], instructions for use [5], spray screen (3232U) [38], carrying
strap [6], shut-o valve [9], spray wand [7], elbow [50] and extendable cap nut [49]. (Fig. 1)
Type of device 3232 3232U
Max. lling amount 5 l (1.32 gal)
Total contents 6.5 l (1.72 gal)
Max. spraying pressure 3 bar
Max. operating temperature 30 °C (104 °F)
Weight when empty 1.8 kg (3.97 lb) 1.9 kg (4.18 lb)
Gross weight max. 7.0 kg (15.42 lb) 7.1 kg (15.65 lb)
Material of tank Polyethylene
Spray wand Brass Plastic
Where device is carried on the side
Technical residual quantity < 0.04 l (1.35 oz)
Max. volume ow 1.0 l/min (0.26 gal/min)
Recoil force < 5 N
Visual inspection: Are the tank [1], pump [2], hose [4], shut-o valve [9], piston pressure
gauge[16], and spray wand [7] and elbow [50] with nozzle [21] undamaged? (Fig. 1)
+Pay special attention to the connections between the tank – hose and the hose – shut-o
valve and to the condition of the pump threading and spray wand.
No leaks: Pump up the empty device to 2 bar (29 psi) (Fig. 11).
► The pressure must not decrease more than 0.5 bar (7,35 psi) within 30 minutes.
Function: Pull up the piston pressure gauge handle [16]. (Fig. 5)
► The pressure must dissipate.
1. Fasten the carrying strap [6] on the tank [1]. (Fig. 2)
2. Push the tube [4] into the xture [10] and secure it with the extendable cap nut [49]. (Fig. 3)
3. Push the hose [4] onto the shut-o valve [9] and secure it with the cap nut. (Fig. 3)
4. Screw the spray wand [7] onto the shut-o valve [9]. (Fig. 3)
5. Screw the elbow [50] onto the spray wand [7]. (Fig. 3)
6. Mount the spray screen (3232U) [38] on the spray wand [7], then sealing ring [53], insert
[52] and nozzle [21]. (Fig. 3)
EN ENGLISH
+You will nd the illustrations referred to above in the pages 3 – 5 of these
instructions for use.
Scope of delivery
Technical data
Table 1
Assembly
Checks
Check the device regularly and after a longer period of non-use, e.g. a winter break.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
+Using the lock [40] the lever on the shut-o valve [9] can be locked and unlocked.
Unintentional spraying is prevented after locking. (Fig. 14)
► If required, reset the lock [40] and activate the shut-o valve [9]. (Fig. 14)
► The shut-o valve must open and close.