18
Spraying pressure 6SUD\TXDQWLW\IRUÀDWVSUD\QR]]OH
1,0 bar (14.5 psi) 0,46 l/min
1,5 bar (21.8 psi) 0,56 l/min
2,0 bar (29.0 psi) 0,65 l/min
3,0 bar (43.5 psi) 0,79 l/min
4,0 bar (58.0 psi) 0,91 l/min
$IWHUXVLQJWKHGHYLFHWLPHVRUDWOHDVWRQFHD\HDU
• Disassemble the pump [2] and grease the diaphragm [22]. )LJ.
&OHDQWKHQR]]OH>@XQGHUÀRZLQJZDWHU(Fig. 18).
5HPRYHWKH¿OWHU>@DQGFOHDQLWXQGHUUXQQLQJZDWHU(Fig. 19).
• Grease the O-rings [21] and [29] (Fig. 17, 22h)
'LVDVVHPEOHWKHVKXWRႇYDOYH>@)LJD
D3XOORႇWKHULQJ>@
a) Loosen the four screws and pull the half shells [42] apart.
E6FUHZWKHVHDOLQJFDS>@IURPWKHYDOYHERG\>@DQGSXOOWKHSUHVVXUHEROW>@IURP
WKHYDOYHERG\>@)LJE
• Grease the O-rings [24] )LJE
$VVHPEOHWKHVKXWRႇYDOYH>@
(PSW\DQGULQVHWKHGHYLFHZLWKFOHDUZDWHU
:LSHRႇWKHGHYLFHZLWKDPRLVWFORWK
)RUGU\LQJDQGVWRULQJWKHGHYLFHNHHSWKHWDQNDQGSXPSVHSDUDWHLQDGU\SODFHSUR-
tected from sunlight and freezing temperatures.
EN ENGLISH
7DEOH'HSHQGHQFH6SUD\LQJUDWH±VSUD\LQJSUHVVXUH
+,IOLTXLGPL[HGZLWKDLUHPHUJHVIURPWKHQR]]OHWKHWDQNLVHPSW\
After Usage
Care and maintenance
,IWKHVSUD\LQJSUHVVXUHGHFUHDVHVPRUHWKDQEDUSVL from the optimum level,
pump some more.
2EVHUYHWKHLQVWUXFWLRQVLQWKHVHFWLRQHQWLWOHG³6DIHW\´
Never leave liquid in the device.
3XOOXSWKHUHGEXWWRQRQWKHVDIHW\YDOYH>@XQWLODOOH[FHVVSUHVVXUHLVUHOHDVHGIURP
the tank. (Fig. 4).
2. Remove the cover [10+11]. (Chapter entitled „Preparation“ Points 2, Fig. 5a + 5b)
Collect and dispose of the residual liquid and the tank according to all applicable
laws, requirements and regulations.
)ROORZWKHLQVWUXFWLRQVRIWKHVSUD\SURGXFWPDQXIDFWXUHU
&OHDQWKHSURWHFWLYHHTXLSPHQWDQG\RXUVHOIHYHU\WLPHDIWHUXVDJH
2EVHUYHWKHLQVWUXFWLRQVLQWKHVHFWLRQHQWLWOHG³6DIHW\´
0DNHFHUWDLQWKHRSWLPXPVSUD\LQJSUHVVXUHLVVHWĺ7DEOH on the pressure gauge [15].
3UHVVXUHUHJXODWLRQ&)9RQWKHVKXWRႇYDOYH