MTX 3292/MTX 3293,
ASYC IV
Portable Digital Multimeter -
100,000 cts X04002A02 - Ed. 1 - 07/14
The full user’s manual is available on the CD supplied with the
instrument. Download is possible from our support site:
www.chauvin-arnoux.com.
This multimeter complies with the EN 61010-1 safety standard on double
insulation for electronic measuring instruments.
IP 67 as per standard IEC 60529.
Symbols used on the instrument:
Warning: Risk of danger.
Refer to the user’s manual to find out about the
potential dangers and any action to be taken in order to
avoid them.
Earth Double insulated
If you use this instrument in a way which is not specified, the protection
provided may be compromised, thus endangering you.
The safety of any system includingthis instrument is the responsibility of the
assembler of the system.
This instrument has been designed for use indoors:
- in an environment with pollution level 2,
- at an altitude of less than 2000 m,
- at a temperature between 0°C and 50°C,
- with relative humidity < 80 % up to 35°C.
It can be used for measurements on the circuits of:
- Category III installations for voltages up to 1,000 V (AC or DC)
relative to earth.
- Category IV installations for voltages up to 600 V (AC or DC)
relative to earth.
-CAT III: Measurement category III corresponds to measurements
carried out on installations in buildings.
Example: measurements on switchboards, wiring, etc.
-CAT IV: Measurement category IV corresponds to the measurements
carried out on the source of low-voltage installations.
Example: meters and measurements on the safety devices protecting
against overcurrents, etc.
For safety reasons, only use suitable cords supplied with the instrument:
they comply with the EN 61010-031 standard. Before each use, make
sure that they are in perfect condition.
When the instrument is connected to the measuring circuits, never touch a
terminal which is not in use. Use only suitable accessories delivered with
the instrument or approved by the manufacturer.
If the measurement category of the accessory is different from that
of the instrument, the lowest category applies to the unit.
6, avenue du Pré de Challes
F-74940 ANNECY-LE-VIEUX
Tél. +33 (0)4.50.64.22.22
MTX 3292 MTX 3293
Display Graphic color (70 x 52)
Power supply 4 R6 batteries (AA format)
or rechargeable batteries
Counts 100 000
Communication IR / USB (Bluetooth, optional)
We thank you for your confidence in the quality of our products.
•Fuse and batteries or rechargeable batteries:
Fuse: 11 A: 10 x 38 - 1000 V
F - breaking capacity: > 18 kA
4 batteries: 1,5 V AA LR6 or batteries 1,2 V Ni-IMH LSD
•Terminal block: with 3 4-m banana inputs and an optical
connector for USB communication:
•Display of the connection on the screen:
Voltage: VAC, VDC, VAC+DC
Graphic display of Mem… in VAC+DC mode:
Frequency: Hz
Resistance: Ω, Diode, Continuity
Capacitance: F
Vinput
2. Graphic mode (default),
but select:
yMeas… for another display
yMEAS+ to select a
secondary function
yREL relative measurement
ySURV for MIN/MAX/AVG
(time-stamped)
ySPEC to get the specs
Trace
Zoom
Cursor
1. Activate "V", then
press F1, F2,F3,F4
to select the coupling:
yAC,
yDC,
yAC+DC or
yVlowZ.
Configuration SETUP Æ
MEASURE to adjust the
parameters: filters,
impedance, reference...
COM input
3. Select Mem... to save or stop a sequence (10 max. and
6,500 measurements)
Consult data by long press on Mem…
1. Activate Ωby pressing this key:
yF2 accesses (continuity),
yF3 accesses 100 Ohm range
yF4 selects the diodes (4V or 26V diode test)
yor subsequent presses
2. Select Meas..., then MEAS+ for the MATH
secondary function, or:
yREL relative measurement
ySURV for time-stamped MIN/MAX/AVG
ySPEC to obtain the specifications.
1. Activate Hz.
2. Select Range ±,
frequency range
and
< 200 kHz or
> 200 kHz
by the keys .
3. Select Meas…, then MEAS+ to select a secondary
function among: MATH, DCY, PER, PW+/-, CNT+/- or:
yREL relative measurement
ySURV for time-stamped MIN/MAX/AVG
ySPEC to obtain the specifications.
1. Activate C by pressing this key.
Pressing:
yF1 accesses Range+
yF2 accesses Range-
Select ranges by those keys .
2. Select Meas..., then:
yREL relative measurement
ySURV for time-stamped MIN/MAX/AVG
ySPEC to obtain the specifications.
COM inputVinput COM input
Vinput
COM inputVinput
RUN is displayed
when the
measurement is
running and
OL is displayed if
the value is >
range or if there
is a short-circuit.