manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. Transmitter
  8. •
  9. MG 17PE User manual

MG 17PE User manual

BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■AUXILIARY POWER SUPPLY RATING & OPERATIONAL RANGE
• Locate the auxiliary power supply rating marked on the
product and confirm its operational range as indicated
below:
24V DC rating: 24V ±10%, approx. 35mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 40 to 85% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
Span Adj.
Zero Adj.
1
78
56
2
34
INSTALLATION
Use Standard Rack (model: 17BXE).
PT TRANSMITTER MODEL 17PE
EM-2938 Rev.2 P. 1 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■CONNECTION DIAGRAM
1
2
LOAD
SOURCE
V
U
v
u
FUSE
FUSE
VT
OUTPUT
AUXILIARY
POWER
CONNECTOR
■TERMINAL ASSIGNMENTS
12
34
78
56
17PE
EM-2938 Rev.2 P. 2 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Auxiliary power input voltage: Check voltage supplied
to the rack (model: 17BXE). For the DC power source, be
sure that the ripple level is within 10% p-p.
3) Input: Check that the input signal is within 0 – 120% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of suffi-
cient accuracy level. Turn the auxiliary power supply on
and warm up for more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.
17PE
EM-2938 Rev.2 P. 3 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Other MG Transmitter manuals

MG BR User manual

MG

MG BR User manual

MG M6SWVS User manual

MG

MG M6SWVS User manual

MG KWRS2 User manual

MG

MG KWRS2 User manual

MG M6NPA User manual

MG

MG M6NPA User manual

MG Mini-M M2VF3 User manual

MG

MG Mini-M M2VF3 User manual

MG Mini-M M2TS User manual

MG

MG Mini-M M2TS User manual

MG M3-UNIT Series User manual

MG

MG M3-UNIT Series User manual

MG Mini-M M2EXV User manual

MG

MG Mini-M M2EXV User manual

MG W5LCS User manual

MG

MG W5LCS User manual

MG 10RS User manual

MG

MG 10RS User manual

MG M60EWVS User manual

MG

MG M60EWVS User manual

MG M3-UNIT Series User manual

MG

MG M3-UNIT Series User manual

MG M6NWVS User manual

MG

MG M6NWVS User manual

MG BCT User manual

MG

MG BCT User manual

MG 10JRE User manual

MG

MG 10JRE User manual

MG M6DCTC User manual

MG

MG M6DCTC User manual

MG FRT User manual

MG

MG FRT User manual

MG 10AC User manual

MG

MG 10AC User manual

MG M3SVS User manual

MG

MG M3SVS User manual

MG 18JPA User manual

MG

MG 18JPA User manual

MG M6SXM User manual

MG

MG M6SXM User manual

MG W5VS User manual

MG

MG W5VS User manual

MG 10MS User manual

MG

MG 10MS User manual

MG Mini-M M2CA User manual

MG

MG Mini-M M2CA User manual

Popular Transmitter manuals by other brands

Decade MS-100 series instruction manual

Decade

Decade MS-100 series instruction manual

Decko 24125 user manual

Decko

Decko 24125 user manual

Sennheiser EM 300 G3 - 01-09 instruction manual

Sennheiser

Sennheiser EM 300 G3 - 01-09 instruction manual

Kopp 8114.0102.9 manual

Kopp

Kopp 8114.0102.9 manual

FlowLine EchoPro LR11 Series manual

FlowLine

FlowLine EchoPro LR11 Series manual

Nautel NV40 troubleshooting manual

Nautel

Nautel NV40 troubleshooting manual

Kramer Cobra T2 user manual

Kramer

Kramer Cobra T2 user manual

Emerson Rosemount 5408 Reference manual

Emerson

Emerson Rosemount 5408 Reference manual

Community Controls Firefly3 manual

Community Controls

Community Controls Firefly3 manual

Chiayo DB-2400 Operation manual

Chiayo

Chiayo DB-2400 Operation manual

V2 ARTEMIS quick start guide

V2

V2 ARTEMIS quick start guide

Okayo C 8812 operating instructions

Okayo

Okayo C 8812 operating instructions

Extron electronics MTP T 15HD A user guide

Extron electronics

Extron electronics MTP T 15HD A user guide

Lightware SW4-TPS-TX240 quick start guide

Lightware

Lightware SW4-TPS-TX240 quick start guide

Status SEM203TC MKII OPERATING SPECIFICATIONS

Status

Status SEM203TC MKII OPERATING SPECIFICATIONS

Critical Environment Technologies ART Operation manual

Critical Environment Technologies

Critical Environment Technologies ART Operation manual

Steren FMT-868 instruction manual

Steren

Steren FMT-868 instruction manual

Multiplex PROFI CAR 301 manual

Multiplex

Multiplex PROFI CAR 301 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.