Installation
Preparing the Site
Select the site that meets the following requirements:
Characteristic Requirement
Temperature 32 to 104˚F (0 to 40˚C)
Humidity Maximum relative humidity of 90%, non-condensing
Condition At least 1.8 meters (6 feet) to the nearest source of electromagnetic noise
Ventilation Minimum 3 inches (0.25 feet) of clearance around the ventilation openings
Power Outlet Within 1.8 meters (6 feet) to the switch
Table 2: SP616DB / SP624DB Operating Requirements
Settling the Switch
zMounted to 19-inch standard rack
Locate the accessories provided in the product package. Use the rack-mount brackets and
screws to install the switch into any EIA 19” standard rack.
Step 1: Attach the brackets to each side of the chassis.
Step 2: Apply the screws to each side and secure them tightly.
Step 3: Carefully position the switch into the rack.
Step 4: Align the brackets to the side holes on the rack and use rack screws to secure the
chassis with the rack.
Step 5: Proceed to the “Connecting to Power” section.
zDesktop or any flat surface
The switch can sit on desktop or any flat surface with adequate space and ventilation. If you
want to place it onto a shelf, make sure the shelf can withstand the weight of the switch.
Step 1: Simply put the switch on the desired place.
Step 2: Ensure the switch receives good ventilation.
Step 3: Proceed to the “Connecting to Power” section.
Installing the Module (optional)
Consult the following illustrations for installation.
Figure 3: Removal of cover plate Figure 4: Fiber module being installed
Step 1: Make sure the power is switched off. The module is not hot-swappable.
LIt may cause electric shock or any possible damage to the switch if the power is not
switched off.
4