Milestone Srl MA210-002 –MAXI-44 eT –User Manual
GETTING STARTED GUIDE
3
Cleaning of IR (easyTEMP) sensors...........................................................17
5.4 EasyTEMP Calibration Test instructions............................18
eT Calibration Test procedure.....................................................................18
6CLEANING INSTRUCTIONS................................20
6.1 General..............................................................................20
6.2 Leaky cover.......................................................................20
6.3 Test of microwave absorption............................................20
6.4 Cleaning of the cover.........................................................21
6.5 Cleaning of protection shield..............................................21
6.6 Cleaning of PTFE vessel...................................................21
7APPENDIX............................................................22
7.1 Regular test (Accessories/vessels/rotors)..........................22
8MAXI-44 ROTOR TIPS AND TECHNIQUES........23
8.1 General working specifications..........................................23
Sample amount...........................................................................................23
Volumes......................................................................................................23
Temperature ...............................................................................................23
Pressure .....................................................................................................23
Acid solutions..............................................................................................23
8.2 MAXI-44 Vessels...............................................................23
Components................................................................................................23
Labeling......................................................................................................24
Usage Log ..................................................................................................24
8.3 Operating tips....................................................................24
Sample Weighing........................................................................................24
Acid addition and digestion temperature .....................................................25
Vessels closure / opening. ..........................................................................26
How to open the vessels (venting) ..............................................................28
Digestion of water/waste water samples (i.e. EPA3015A method) ..............28
Active cooling after every run......................................................................29
8.4 Cleaning............................................................................30
Clean and dry between runs .......................................................................30
Cleaning vessels and covers.......................................................................30
Cleaning vessels and covers.......................................................................30
Surface Cleaning ........................................................................................30