Milwaukee ORP57 User manual

CERTIFICATION
Milwaukee Instruments conform to the CE
European Directives.
RoHS
COMPLIANT
Disposal of Electrical & Electronic
Equipment. Do not treat this product
as household waste. Hand it over to
the appropriate collection point for the
recycling of electrical and electronic
equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them
with other household waste. Hand them
over to the appropriate collection point for
recycling.
Please note: proper product and
battery disposal prevents potential
negative consequences for human
health and the environment. For
detailed information, contact your local
household waste disposal service or go to
www.milwaukeeinstruments.com (USA
& CAN) or www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is
entirelysuitableforyourspecificapplication
and for the environment in which it is used.
Any modification introduced by the user to
the supplied equipment may compromise
the tester’s performance. For your and
the tester’s safety do not use or store
the tester in hazardous environment. To
avoid damage or burn, do not perform any
measurement in microwave ovens.
WARRANTY
This instrument is warranted against
defects in materials and manufacturing for a
period of 2 years from the date of purchase.
Probe is warranted for 6 months. This
warranty is limited to repair or free of charge
replacement if the instrument cannot
be repaired. Damage due to accidents,
misuse, tampering or lack of prescribed
maintenance is not covered by warranty.
If service is required, contact your local
Milwaukee Instruments Technical Service.
If the repair is not covered by the warranty,
you will be notified of the charges incurred.
When shipping any tester, make sure it is
properly packaged for complete protection.
Milwaukee Instruments reserves the right to
make improvements in design, construction
and appearance of its products without advance
notice.
USER MANUAL
ORP57
PRO Waterproof 2-in-1
ORP / Temperature
Tester
ORP57 PRO
milwaukeeinstruments.com (USA & CAN)
milwaukeeinst.com
ISTORP57 11/20-1
SATISFACTION
GUARANTEED
Mai
n
LCD
Measuring Unit on Main LCD
In
stability
Indicator
Battery
Indicator
Temperature Reading
on Secondary LCD
OPERATIONAL GUIDE
yRemove the electrode and turn the tester
on by pressing the ON/OFF button. All the
used segments on the LCD will be visible
for 1 second or as long as the button is
pressed.
yImmerse the electrode in the solution to
be tested. Stir gently and wait for stable
reading, i.e. the instability indicator
(hourglass) on the LCD turns o.
yThe ORP (mV) value will be displayed on
the main LCD, while the temperature is
shown on the secondary LCD.
yTo freeze the display, while in
measurement mode, press and hold the
SET/HOLD button. The “HOLD” message
appears on the secondary display and
the reading will be frozen on the LCD.
Press any button to return to normal
mode.
yTo turn the tester o, press the ON/OFF
button. The “OFF” message will appear
on the secondary display. Release the
button.
Note: The tester is factory calibrated.
Contact the nearest Service Center for
periodic recalibration.
°C/°F SELECTION
yPress and hold the ON/OFF button
until the secondary LCD shows “TEMP”
and the current temperature unit (e.g.
TEMP°C).
yUse SET/HOLD to select the unit (°C or
°F); then press again ON/OFF to return to
the normal mode.
ELECTRODE REPLACEMENT
yRemove the protective cap and unscrew
the plastic ring on the top of the electrode.
yPull out the MI57P electrode and replace
it with a new one.
yMake sure the gaskets are in place
before screwing back the ring.
BATTERY REPLACEMENT
When the batteries become weak, the
battery symbol on the LCD will light up to
advise that only a few hours of working
time is remaining.
The tester is also provided with BEPS
(Battery Error Prevention System), which
avoids any erroneous readings due to low
battery level by automatically switching
the tester o.
It is recommended to replace the batteries
immediately. To replace the batteries
unscrew the battery compartment cap and
replace all four 1.5V batteries while paying
attention to their polarity. Make sure the
gasket is in place before screwing back the
cap.
Batteries should only be replaced in a
non-hazardous area using the battery type
specified in this instruction manual.
ACCESSORIES
MI57P Replaceable electrode for
ORP57
MA9015 Electrode storage solution,
230 ml
MA9016 Electrode cleaning solution,
230 ml
M10000B Electrode rinse solution, 20 ml
sachet, 25 pcs.
SPECIFICATIONS
Range ±1000 mV (ORP)
-5.0 to 60.0 °C / 23.0 to 140.0°F
Resolution 1 mV
0.1 °C / 0.1 °F
Accuracy
(@25 °C)
±2 mV
±0.5 °C / ±1 °F
Typical EMC
Deviation
±2 mV
±0.3 °C / ±0.6 °F
Calibration Factory calibrated
Probe Replaceable MI57P
Environment -5 to 50 °C; 100% RH max.
Battery Type 4 x 1.5V; IEC LR44, A76
Battery Life approx. 300 hours of use
Auto-o after 8 minutes of non-use
Dimensions 200 x dia 38 mm
Weight 100 g

Other Milwaukee Test Equipment manuals

Milwaukee MW10 User manual

Milwaukee

Milwaukee MW10 User manual

Milwaukee CD97 User manual

Milwaukee

Milwaukee CD97 User manual

Milwaukee MW14 User manual

Milwaukee

Milwaukee MW14 User manual

Milwaukee ORP57 User manual

Milwaukee

Milwaukee ORP57 User manual

Milwaukee pH600 User manual

Milwaukee

Milwaukee pH600 User manual

Milwaukee pH54 User manual

Milwaukee

Milwaukee pH54 User manual

Milwaukee pH51 User manual

Milwaukee

Milwaukee pH51 User manual

Milwaukee MW14 User manual

Milwaukee

Milwaukee MW14 User manual

Milwaukee 2210-20 User manual

Milwaukee

Milwaukee 2210-20 User manual

Milwaukee pH55 PRO User manual

Milwaukee

Milwaukee pH55 PRO User manual

Milwaukee MW803 User manual

Milwaukee

Milwaukee MW803 User manual

Milwaukee pH58 User manual

Milwaukee

Milwaukee pH58 User manual

Milwaukee HEAVY DUTY 2216-40 User manual

Milwaukee

Milwaukee HEAVY DUTY 2216-40 User manual

Milwaukee MW12 User manual

Milwaukee

Milwaukee MW12 User manual

Milwaukee MW804 User manual

Milwaukee

Milwaukee MW804 User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Milwaukee EC59 User manual

Milwaukee

Milwaukee EC59 User manual

Milwaukee 2237-40 User manual

Milwaukee

Milwaukee 2237-40 User manual

Popular Test Equipment manuals by other brands

nvent Schroff 21265-010 user manual

nvent

nvent Schroff 21265-010 user manual

Teledyne FST-040 manual

Teledyne

Teledyne FST-040 manual

Netscout aircheck G2 user manual

Netscout

Netscout aircheck G2 user manual

Ocean Safety Jon Buoy mk4 operating instructions

Ocean Safety

Ocean Safety Jon Buoy mk4 operating instructions

YOKOGAWA CA150 user manual

YOKOGAWA

YOKOGAWA CA150 user manual

Hioki 3511-50 instruction manual

Hioki

Hioki 3511-50 instruction manual

Jinhan ADO102 manual

Jinhan

Jinhan ADO102 manual

Agilent Technologies Ininiium 90000 datasheet

Agilent Technologies

Agilent Technologies Ininiium 90000 datasheet

Kenwood CS-1022 instruction manual

Kenwood

Kenwood CS-1022 instruction manual

Noyes SMLP 5-5 user guide

Noyes

Noyes SMLP 5-5 user guide

LEM HEME GEO 15 operating instructions

LEM

LEM HEME GEO 15 operating instructions

METREL EasiPLUS MI 3000 instruction manual

METREL

METREL EasiPLUS MI 3000 instruction manual

Platinum Tools VDV MapMaster quick start guide

Platinum Tools

Platinum Tools VDV MapMaster quick start guide

Sealey VS925 instructions

Sealey

Sealey VS925 instructions

Viavi AVX-10K Operation manual

Viavi

Viavi AVX-10K Operation manual

Megger MIT1020/2 user manual

Megger

Megger MIT1020/2 user manual

Renkforce TFT FiT239C operating instructions

Renkforce

Renkforce TFT FiT239C operating instructions

Perel EEM800 user manual

Perel

Perel EEM800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.