manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Mitsubishi Electric
  6. •
  7. Conference System
  8. •
  9. Mitsubishi Electric MODBUS TCP User manual

Mitsubishi Electric MODBUS TCP User manual

MODBUS®TCP Communication Unit for Energy Measuring Unit (EMU4-FD1-MB)
Model EMU4-CM-MT
User's Manual
・Before using the product, please read this manual carefully to ensure correct use.
・Make sure that the end users read this manual and then keep the manual in a safe place for future reference.
・Make sure to deliver this manual to the end-user.
About this manual
You can download User's manual of this Unit from the following site.
http://www.mitsubishielectric.co.jp/haisei/lvs/downloads/handling.htm
1. Features
This Unit is the optional dedicated product for Energy Measuring Unit (EcoMonitorLight Model: EMU4-FD1-MB)
This Unit enables to transfer measured data to programmable controllers for data acquisition via MODBUS®TCP communication.
2. Checking package content
These following items for this device are included in package. Check that no items are missing.
(1) MODBUS®TCP Communication Unit×1 (2) User’s manual ×1
3. Safety Precautions
3.1 Precautions for Operating Environment and Conditions
This Unit is premised on being used in pollution degree II environment. When used in higher pollution degree, protect this Unit from pollution on another device side to be incorporated.
For the definition of the pollution degree and the over voltage category, refer to EN61010-1/2010.
Do not use this product in the places listed below. Failure to follow the instruction may cause malfunctions or decrease of product-life.
・Places the Ambient temperature exceeds the range-5-+55°C
・Dust, corrosive gas, saline and oil smoke exist
・Places the Relative humidity exceeds the range 30-85% or places with dewfall
・Places exposed to rain or water drop
・Operating altitude exceeds 2000m
・Vibration and impact exceed the specifications
・Places metal fragments or conductive substance are flying
・Places the average daily temperature exceeds +35°C
・Places in strong electromagnetic field or places large amounts of external noise exist
・Places exposed to direct sunlight
This unit is the open type device, which are designed to be housed within another device for prevention of electric shock. House this unit within the device such as the control panel
before use. (Indoor use)
3.2 Matters concerning the precaution before use
・Use the Unit in the specified usage environment and conditions.
・Before using this Unit, set MODBUS®TCP IP address, Subnet mask, Default gateway existence and Default gateway address.
※Please refer to “user’s manual of EMU4-FD1-MB”.
3.3 Installation Precautions
・For installation and wiring works, make sure that the power source is shut off for all outside phases.
If all phases are not turned off, it may cause an electric shock or product damages.
・Any person who is involved in installation and wiring of this Unit should be fully competent to do this work.
・Work under the electric outage condition when installing and wiring. Failure to do so may cause electric shock or a failure of the Unit, a fire etc.
・In 100Mbps communication by the 100BASE-TX connection, a communication error may occur under the influence of high frequency noise from devices other
than this device in the installation environment.
・Take the following action to prevent the influence of high frequency noise in the construction of a network system.
(1) Wiring connection
・Do not install a twisted pain cable together with the main circuit and power cables, etc.
・Place the twisted pair cable in a duct.
(2) Communication system
・Increase the number of communication retries if necessary.
・Change the hub used for connection into a 10Mbps hub, and make communication at a transmission speed of 10Mbps.
3.4 Precautions for Use
・
Before operating the product, check that active bare wire and so on does not exist around the product. If any exposed conductor is found, stop the operation immediately and take
an appropriate action such as isolation protection
・In the event of a power outage during the setting, the Unit is not set correctly. Please set again after power recovery.
・When you connect to Energy Measuring Unit of the Unit, Contrast of the LCD display of Energy Measuring Unit is reduced to small.
・Do not touch the live part. It may cause electric shock, electric burn injury or burnout of the device.
・Work under the electric outage condition when installing and wiring.
・Do not disassemble or modify this Unit It may cause failure, malfunction, injury or fire.
・Do not touch the MODBUS®TCP communication connectors when communicating. It may cause a malfunction or failure of the Unit.
・Push the RESET switch with an appropriate force (1.6N). The addition of force than necessary, it may cause a malfunction or failure of the Unit.
3.5 Maintenance Precautions
・Use a soft dry cloth to clean off dirt of the Unit surface. Do not let a chemical cloth remain on the surface for an extended period of time nor wipe the surface with thinner or benzene.
・Check for the following items to use this Unit properly for long time.
(1) No damage on this Unit
(2) No abnormality with LED indicators
(3) No abnormal noise, smell or heat
(4) No looseness with installation and wire connection
(Check item No.4 under the power failure condition. Failure to do so may cause electric shock, failure of the Unit or a fire.)
3.6 Storage Precautions
To store this Unit, put it in a plastic bag. For long-time storage, avoid the following places. Failure to follow the instruction may cause a failure and reduced life of the Unit.
・Places the ambient tempe rature exceeds the range -10-+60°C
・Places the average daily temperature exceeds +35°C
・Places exposed to rain, water drop or direct sunlight
・Places the Relative humidity exceeds the range 30-85% or places with dewfall
・Vibration and impact exceed the specifications
・Places metal fragments or conductive substance are flying
・Places where dust, corrosive gas, saline and oil smoke exist
3.7 Disposal Precautions
・When disposing of this Unit, treat it as industrial waste.
3.8 About packaging materials and this manual
For reduction of environment load, packaging materials are produced with cardboard, and this manual is printed on recycled paper.
If you are considering using this module for special purpose such as nuclear power plants,
aerospace, medical care or passenger vehicles please refer to our sales representative.
1)
2)
3)
4)
LED
Connector for MODBUS®TCP communication
IEC rail stop
Connection stop
Operation status of MODBUS®TCP communication is displayed.
10BASE-T/100BASE-TX connector (RJ45)
This is used to fix to an IEC rail.
This is used to connect the MODBUS®TCP communication Unit to the Energy Measuring Unit.
5. How to wire
6. Mounting the Unit
Connect the MODBUS®TCP communication Unit to the Energy Measuring Unit.
*This unit can be attached to EcoMonitorLight in below.
There are two mounting methods, surface mounting and panel mounting.
(1) Remove the blank label stuck to the side of
the Energy Measuring Unit.
(2) Insert the connector of the MODBUS®TCP communication
Unit into the connector of the Energy Measuring Unit and
make these Units closely-attached.
(3) Slide the connection stops (green-colored) of upper
and lower of the MODBUS®TCP communication
Unit to lock it.
6.1 Mounting the Unit on an IEC rail
4. Name and function of each part
<Name and function of each part>
Front view Left-side view Back view
1)
2) 4)
4)
3)
・Work under the electric outage condition when connecting the Energy Measuring Unit. Failure to do so may cause electric shock, a failure of the Unit, a fire etc.
CAUTION
CAUTION
CAUTION
DANGER
CAUTION
DANGER
<Daily maintenance>
Name of part Functions
No.
*This unit can be attached to EcoMonitorLight in below. This unit can be attached to EcoMonitorPlus as well.
More than 7.3
35
1
27
●Applicable IEC rail ●Mounting ●How to remove
(1) Hold the module and pull the stopper
of IEC rail down.
(1) Hold the module and pull the
stopper of IEC rail down.
(4) Push the stopper of
the IEC rail above.
(2) Hook on the rail
(2) Pull tha module
IEC rail
(3) Push the Unit
Blank label DISP
+/PHASE
−
/RESET
SET
Model
EMU4-FD1-MB
6.2 Screw mounting
●Panel cut dimension ●Attachment
6.3 Screw mounting (When using the attachment for panel mounting)
●Panel cut dimension
●Attachment
Recommended
mounting screw
Cross recessed pan-head screw with captive spring
or plain washer JIS B 1188
Two screws (M3×10)
Attachment
Attach the plate by screws (M3×10).
Tightening torque:0.63N・m
Mount on the plate by screws (M3×10), then mount the panel mounting
attachment on the plate. Tightening torque:0.63N・m
Mounting screw
*1. The mounting screws and the screws for fixing the attachment are included in
Attachment (optional part).
*2. Before use, you need to cut each part of the attachment.
Screws for
fixing the attachment
(*1)
Attachment plate
Mounting screw (*1)
Cut
(*2)
Attachment for
panel mounting
External dimensions of
MODBUS®TCP communication Unit
Unit:mm
LAN
(PC)
<Basic Specifications>
<MODBUS®TCP Communication specifications>
Energy Measuring Unit (EMU4-FD1-MB) MODBUS®TCP Communication Unit
EMU4-CM-MT
EMC:EN-61326-1:2013
from -5 to +55°C (average daily temperature is not more than +35°C)
30-85% RH (No condensation)
from -10 to +60°C
Not more than 2000m
0.1kg ※Mass of the MODBUS®TCP Communication Unit only
Energy Measuring Unit
EcoMonitorLight Model:EMU4-FD1-MB
Accommodating model
Operating humidity
Storage temperature
Operating altiude
*1. This is the maximum number of cascade connection stages when a repeater hub is used.
For the maximum number of cascade connection stages, contact to the manufacturer for the switching hub used.
*2. Length between a hub and a node.
If you have any questions or the product is broken down, contact our sales representative near you
・The charge-free warranty is effective until the earlier of 1 year after the date of your purchase or 18 months after manufacturing.
・The gratis warranty shall apply if the product fails even though it is being used properly in the conditions, with the methods and under the environments in accordance with the
terms and precautions described in the catalogs, the instruction manual, caution label on the product, etc.
・Regardless of Gratis Warranty Period, our company shall not be liable to compensate for any loss arising from events not attributable to our company, opportunity loss and lost
earning of the customer due to failure of the product, and loss, secondary loss, accident compensation, damage to other products besides our products and other operations
caused by a special reason regardless of our company's predictability.
・If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, Japan
Please refer to "catalog" or “user’s manual (Details)” for more detail.
・Use the RJ-45 connector to the EMU4-CM-MT.
CAUTION
・If an abnormal sound, bad-smelling smoke, fever break out from this Unit, switch it off promptly and don't use it.
CAUTION
Product
Mass
Standard
Operating temperature
Usage
environment
Model
Item Specifications
1 port (10BASE-T/100BASE-TX)
Base band
Max. 4 stages (10BASE-T), Max. 2 stages (100BASE-TX)
100m (328.08ft.)
200m (656.16ft.)
Number of cascade connection stages *1
Maximum node-to-node distance
Interface
Maximum segment length *2
Transmission method
RJ45
Connector applicable for external wiring
Cable compliant with the IEEE802.3 10BASE-T Standard (unshielded twisted pair cable (UTP cable), Category 3 or more)
Cable compliant with the IEEE802.3 100BASE-T Standard (shielded twisted pair cable (STP cable), Category 5 or more)
MODBUS®TCP (Port number 502)
Auto negotiation (10BASE-T/100BASE-TX automatically detected)
Auto MDIX function (straight/crossover cable automatically detected)
Max. 4 connection
Protocol
Number of simultaneously connection
Cable 10BASE-T
100BASE-TX
Functions supported
Item Specifications
External dimensions of
MODBUS®TCP communication Unit
External dimensions of
Energy Measuring Unit
7. External dimensions
8. Wiring Diagram
9. Specifications
10. After-sales service
11. Customer Service
External dimensions of
Energy Measuring Unit
DISP
+/PHASE
−
/RESET
SET
Model
EMU4-FD1-MB
(Measuring unit)
(Measuring unit)
(Measuring unit)
(Measuring unit)
(Attachment)
(Attachment)
25 60
15
4
35.427
4
4.590
17.6
4.5
6.6
LY304Z273H01 IB63D24

This manual suits for next models

1

Other Mitsubishi Electric Conference System manuals

Mitsubishi Electric GOT 1000 Series User manual

Mitsubishi Electric

Mitsubishi Electric GOT 1000 Series User manual

Mitsubishi Electric GOT 1000 Series User manual

Mitsubishi Electric

Mitsubishi Electric GOT 1000 Series User manual

Mitsubishi Electric FR-A5ND User manual

Mitsubishi Electric

Mitsubishi Electric FR-A5ND User manual

Mitsubishi Electric GOT1000 GT15 User manual

Mitsubishi Electric

Mitsubishi Electric GOT1000 GT15 User manual

Mitsubishi Electric GT15-J71GP23-SX User manual

Mitsubishi Electric

Mitsubishi Electric GT15-J71GP23-SX User manual

Popular Conference System manuals by other brands

TANDBERG 1500 MXP Installation

TANDBERG

TANDBERG 1500 MXP Installation

THOMSON REMOTE COMMUNICATION - V3.0 user manual

THOMSON

THOMSON REMOTE COMMUNICATION - V3.0 user manual

Himsa NOAHlink user manual

Himsa

Himsa NOAHlink user manual

Cisco Quick Set C20 reference guide

Cisco

Cisco Quick Set C20 reference guide

Sennheiser WiCOS C instruction manual

Sennheiser

Sennheiser WiCOS C instruction manual

thereNow iris LiveView user guide

thereNow

thereNow iris LiveView user guide

Mitel MiVOICE BUSINESS installation guide

Mitel

Mitel MiVOICE BUSINESS installation guide

Crestron UC-MX150-Z quick start

Crestron

Crestron UC-MX150-Z quick start

Adena RADA A-BR01 Quick installation guide

Adena

Adena RADA A-BR01 Quick installation guide

Nolan N-Com MCS II Safety and instructions for use

Nolan

Nolan N-Com MCS II Safety and instructions for use

Yealink MeetingEye 600 quick start guide

Yealink

Yealink MeetingEye 600 quick start guide

Asus GQE100 user guide

Asus

Asus GQE100 user guide

Valcom InformaCast VIP-9890AL-CB-IC manual

Valcom

Valcom InformaCast VIP-9890AL-CB-IC manual

RGBlink TAO 1mini-HN quick start

RGBlink

RGBlink TAO 1mini-HN quick start

RADVision SCOPIA XT4000 Series user guide

RADVision

RADVision SCOPIA XT4000 Series user guide

golmar ART 4 LITE/G2+ user manual

golmar

golmar ART 4 LITE/G2+ user manual

Toa YW-1022 instruction manual

Toa

Toa YW-1022 instruction manual

Biamp TesiraFORTÉ X Series manual

Biamp

Biamp TesiraFORTÉ X Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.