multicomp pro MP700121 User manual

1
Handheld Optical Power Meter
Model No. MP700121 and MP700122
2
Read all instructions before using the appliance and retain for future reference.
• Please follow all safety operation instructions.
• Children should be supervised to ensure that they do not play with the product.
• Do not use the monitor if the casing is damaged or there is any anomaly that may
impair it’s function.
• Do not use the product for any purpose other than that for which it is designed.
• Do not operate the product around explosive gas, vapour, or dust.
• Do not operate or store in an environment of high humidity or where moisture may
enter the product.
• Turn the meter off when not in use to save the battery.
• Remove the battery if the monitor is not to be used for long periods.
• Replace the battery as soon as the low battery warning appears on the display to
avoid possible incorrect readings.
PRODUCT OVERVIEW
WHAT’S INCLUDED
• Optical power meter
• FC locking adaptor
• Instruction manual
• Cloth storage bag
• 3 x 1.5V AA batteries
IMPORTANT SAFETY INFORMATION
1. Flashlight
2. Auto power off
3. Fault symbol
4. Wavelength value
5. Low battery warning
6. Measurement unit
7. Optical power value
8. Calibration indicator
1. Power button
2. Auto off button
3. Backlight/torch button
4. Zero reset button
5. Measurement value button
6. Wavelength value button
7. LCD display
1
3
4
7
5
6
2
1
2
3 4 5
6
8
7
3
FUNCTIONS
Function buttons
• Press the power button to turn the meter on or press and hold to turn off the
meter.
• Press the AUTO OFF button to enable the auto power off timer. The meter will turn
off after 10 minutes inactivity. The symbol displays on the LCD when active.
• Press the LIGHT button briey to turn on the backlight function on or off. The
backlight automatically turns of after 2 minutes if no button is pressed.
• Press and hold the LIGHT button to activate the ashlight (torch) feature. The
symbol displays on the LCD.
• Press and hold ZERO button to reset the meter to default. All elements of the LCD
display briey.
• Press the DB button to switch between the relative power mode (dB) and absolute
power mode (dBm) to measure optical power at the corresponding wavelength.
• Press the l button to select the wavelength. The LCD displays the gure chosen.
Self Calibration Mode
• Press both ZERO and LIGHT buttons simultaneously to enter the self calibration
mode. CAL is displayed on the LCD.
• Press the LIGHT button to add 0.5dB and press dB button to decrease by 0.5dB.
• After adjusting press power button to save the calibration setting.
Factory reset
• Press and hold ZERO and AUTO OFF buttons simultaneously to restore the factory
settings.
OPERATION
Measurement of Absolute and Relative Power
Absolute Power Measurement
• Set the test wavelength and access the test optical signal. The LCD screen will
display the measured linear value (in mw, nw, pw) and non-linear value (in dBm) of
the absolute optical power.
Relative Power (Loss) Measurement (used in conjunction with light source)
Note: Relative power measurement is mainly used to measure insertion loss or bre link
loss.
• Use a standard test jumper to connect the output port of the light source to the
detection port of the optical power meter.
• Set the test wavelength and access the test optical signal. Then the screen will
display the measured linear value (in mw, nw, pw) and nonlinear value (in dBm) of
the absolute optical power.
• Press the “dB” key. The absolute optical power measured by the optical power
meter will be saved as the reference power value and displayed as xx.xx dBm on
the second line of the LCD screen.
• Connect the jumper to be tested to the light source and the optical power meter.
The difference between the current optical power value and the reference power
value will be calculated by the optical power meter and displayed as y.yy dB on the
third line of the LCD screen, which is approximately insertion loss of the jumper.
Note:
1. P {Reference power value) (dBm)= p (Light source output power) (dBm)-L (Insertion
loss of the std test jumper) (dB)
4
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL &
ELECTRONIC EQUIPMENT.
These symbols indicate that separate collection of Waste Electrical and Electronic Equipment
(WEEE) or waste batteries is required. Do not dispose of these items with general household
waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries
can be returned to any waste battery recycling point which are provided by most battery retailers.
Contact your local authority for details of the battery and WEEE recycling schemes available in
your area. Made in China. LS12 2QQ
Man Rev 1.0
2. L (Insertion loss of the jumper to be tested) (dB)= [P (reference power value)
(dBm)-p (current power value) (dBm)] -L (Insertion loss of the std test jumper) (dB)
Frequency identication function
• When connected to the light source with 270Hz, 1000Hz or 2000Hz signal, the
optical power meter will automatically recognize the frequency and display XXXX
Hz on the LCD.
MAINTENANCE
SPECIFICATIONS
• Please keep the end face of the sensor clean, free from grease and contamination.
• Do not use unclean or non-standard adapter connectors.
• Replace the connector dust cap when not in use.
• Clean the casing using a moist cloth and mild detergent. Do not use any form of
solvents.
• When the low battery symbol displays on the LCD, remove the 4 screws in the
battery cover on the back of the meter and replace the 3 x 1.5V AA batteries to
avoid any inaccuracies in readings taken.
USB charging port
• This feature is for charging of internal lithium batteries only and is not implemented
on this model.
Mode Description
Wavelength range 800nm~1700nm
Calibrated
wavelength
850nm, 980nm, 1300nm, 1310nm, 1490nm, 1550nm,
1625nm, 1650nm
Measurement range -70dBm~+10dBm (MP700121)
-50dBm~+26dBm (MP700122)
Accuracy ±5%
Display resolution Linear: 0.1%, logarithmic: 0.01dBm
Connection Universal connector FC/SC/ST (manually held)
(FC can be locked into place using included adapter)
Detector type lnGaAs
Flashlight LED

This manual suits for next models

1

Other multicomp pro Measuring Instrument manuals

multicomp pro MP005768 User manual

multicomp pro

multicomp pro MP005768 User manual

multicomp pro MP780119 User manual

multicomp pro

multicomp pro MP780119 User manual

multicomp pro MP700852 User manual

multicomp pro

multicomp pro MP700852 User manual

multicomp pro MP760607 User manual

multicomp pro

multicomp pro MP760607 User manual

multicomp pro MP780117 User manual

multicomp pro

multicomp pro MP780117 User manual

multicomp pro MP760862 User manual

multicomp pro

multicomp pro MP760862 User manual

multicomp pro MP780002 User manual

multicomp pro

multicomp pro MP780002 User manual

multicomp pro MP780905 User manual

multicomp pro

multicomp pro MP780905 User manual

multicomp pro MP001186 User manual

multicomp pro

multicomp pro MP001186 User manual

multicomp pro MP780649 User manual

multicomp pro

multicomp pro MP780649 User manual

multicomp pro MP780859 User manual

multicomp pro

multicomp pro MP780859 User manual

multicomp pro MP700022 User manual

multicomp pro

multicomp pro MP700022 User manual

multicomp pro MP770291 User manual

multicomp pro

multicomp pro MP770291 User manual

multicomp pro MP780904 User manual

multicomp pro

multicomp pro MP780904 User manual

multicomp pro MP60607 User manual

multicomp pro

multicomp pro MP60607 User manual

multicomp pro MP780647 User manual

multicomp pro

multicomp pro MP780647 User manual

multicomp pro MP780896 User manual

multicomp pro

multicomp pro MP780896 User manual

multicomp pro MP700006 User manual

multicomp pro

multicomp pro MP700006 User manual

multicomp pro MP760861 User manual

multicomp pro

multicomp pro MP760861 User manual

multicomp pro MP780966 User manual

multicomp pro

multicomp pro MP780966 User manual

multicomp pro MP780994 User manual

multicomp pro

multicomp pro MP780994 User manual

multicomp pro MP780118 User manual

multicomp pro

multicomp pro MP780118 User manual

multicomp pro MP780892 User manual

multicomp pro

multicomp pro MP780892 User manual

multicomp pro MP700506 User manual

multicomp pro

multicomp pro MP700506 User manual

Popular Measuring Instrument manuals by other brands

AEMC instruments 6505 user manual

AEMC instruments

AEMC instruments 6505 user manual

DynAmp LKP-180 Installation, operation and service instructions

DynAmp

DynAmp LKP-180 Installation, operation and service instructions

Pintek PA-622 instruction manual

Pintek

Pintek PA-622 instruction manual

IDEAL SPLIT-JAW 61-096 instructions

IDEAL

IDEAL SPLIT-JAW 61-096 instructions

netvox R718AB user manual

netvox

netvox R718AB user manual

Topcon RL-VH3G instruction manual

Topcon

Topcon RL-VH3G instruction manual

FLIR CM275 user manual

FLIR

FLIR CM275 user manual

Anritsu MS2690A Operation manual

Anritsu

Anritsu MS2690A Operation manual

Arkon MAGX2 user guide

Arkon

Arkon MAGX2 user guide

Roche CoaguChek XS Plus user manual

Roche

Roche CoaguChek XS Plus user manual

Minix AIR-02 instruction manual

Minix

Minix AIR-02 instruction manual

Quanta Computer ecg103-K1 user manual

Quanta Computer

Quanta Computer ecg103-K1 user manual

Hach NA5600 sc Na+ Operations

Hach

Hach NA5600 sc Na+ Operations

Kobold HND-P Series operating instructions

Kobold

Kobold HND-P Series operating instructions

AquaMaster Tools S300 Pro 2 user manual

AquaMaster Tools

AquaMaster Tools S300 Pro 2 user manual

GHM GREISINGER operating manual

GHM

GHM GREISINGER operating manual

Amazon B005PJJ89U instruction manual

Amazon

Amazon B005PJJ89U instruction manual

TSI Instruments DUSTTRAK 854201-M1 Assembly guide

TSI Instruments

TSI Instruments DUSTTRAK 854201-M1 Assembly guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.