HOLD-DOWN FUNCTIONS
Unless otherwise specified, "Hold-Down"
Function keys must be held down for 2 seconds
until the function beep sounds.
Key [1]: BELL/BATTERY TEST
Momentarily sounds the burglar alarm. If the
alarm does not sound, or if it is weak, the battery
may need replacing. Make this test weekly.
(Hold down Key [1] for about 2 seconds). In
commercial installations, if the bell does not
sound when tested, call for service.
Key [2]: DISPLAY BYPASS
(BYPASS PROGRAMMED? YES NO)
Numerically displays zones that have been
bypassed using Key [B]. To display bypassed
zones, hold down Key [2] until the sounder
beeps and all zones have been displayed.
Key [3]: DISPLAY STATUS
Numerically displays zones that are not se-
cured. To display status, hold down Key [3] until
sounder beeps and all zones have been dis-
played.
Key [4]: INSTANT PROTECTION
Cancels entry delay period when arming. The
delay is restored after you disarm the system.
To perform this function, hold down Key [4] for
about 2 seconds, until the function beep sounds.
Key [5]: CHIME (CHIME ZONES___________)
This will enable a feature that sounds a
"chime" (beep) at the keypad each time a pro-
grammed zone (Zone 1 in MA854) is opened.
To disable the chime feature, hold down Key [5]
again (until sounder beeps). (Also see Bypass-
ing Interior Zones).
Key [6]: TELCO TEST
(ENABLED? YES NO)
(Applicable only to systems programmed to
report to a central station. In MA1016-Series
systems, this feature operates only on Area-1
keypads or on Area-2 keypads while in the Man-
ager's Mode).
KEYPAD FUNCTIONS AND CONTROLS
5
KEYPAD FUNCTIONS AND CONTROLS
Pressing the key tests your telephone lines
(the sounder will start to pulse). If the line is
good, the pulsing will stop; if not, a steady
tone will sound. To initiate this test, hold
down Key [6] for about 2 seconds, until func-
tion beep sounds. Reset the sounder using
Key [9].
(Note: In MA1016-Series UL commercial
burglar alarm installations, Failure to Commu-
nicate is indicated by Zone No. __(Area 1),
__(Area 2). With the panel disarmed, the
STATUS LED will be flashing and the keypad
sounder will be pulsing. With the panel
armed, the ARMED LED will be flashing and
the zone number will be displayed).
Key [7]: WATCH MODE (MA1016 Series)
Simultaneously turns on all Day Zones.
The Watch Mode is disabled upon arming.
Note: (1) In all other models (except
MA854), the Watch Mode may have been
programmed to activate when bypassing a
group of zones simultaneously. See PRO-
TECTING YOURSELF WHILE ON THE
PREMISES: Bypassing Interior Zones. (2)
If turning on the Watch Mode just after dis-
arming, first hold down Key [9], then Key [7].
Holding down Key [7] within 10 seconds after
disarming will enable the Fault-Find Mode
(for installer's use only). (Arming the panel
will cancel the Fault-Find Mode.)
Key [8]: PROGRAM
Allows you to enter the Program Mode. In
this mode, you can program your personal-
ized User Codes, a Service Code (not in
MA854) and, in MA1016-Series panels, an
Access Code and a Manager's Code. (Refer
to SELECTING AND PROGRAMMING
YOUR CODES for more information). Hold
down Key [8] for about 2 seconds, until the
function beep sounds.
Key [9]: RESET
Resets any sounder indication, system
trouble indication (not in MA854), Day-Zone
indication, or may be programmed to reset
the Fire Zone. After an alarm occurs and the
system is disarmed, the numerical display will
still indicate which non-24-Hour Zone(s)
caused the alarm. Use Key [9] to clear the
display. The Reset Key is also used to by-
pass a Priority with Bypass Zone. To reset a
function, hold down Key [9] for about 2 sec-
onds, until the function beep sounds.
Key [*]: FUNCTION LIST
Displays Hold-Down Functions. Hold down
button for about 2 seconds, then Hold-Down
Functions will continue to scroll as long as
button is depressed.
Key [B]: ALARM HISTORY
This will display the last alarm condition.
History is not lost when the system is re-
armed; the previous alarm history will remain
in alarm memory until automatically reset by
a new alarm condition. To check alarm his-
tory, hold down Key [B] for about 2 seconds,
until the function beep sounds, then continue
to hold it down until all information has been
displayed.
Key [#]: ZONE LIST
Displays a directory of programmed zone
descriptions. Hold down Key [#] for about 2
seconds, until the function beep sounds.
Zone descriptions will continue to scroll as
long as the button is depressed.
Keys [F], [P] and [A]: PANIC BUTTONS
If enabled, momentarily pressing one of
these keys together with Key [#] will immedi-
ately activate a Panic Zone. Refer to PRO-
TECTING YOURSELF WHILE ON THE
PREMISES: Emergency Buttons.

Other manuals for Magnum Alert RP1000ELCD

1

Other NAPCO Keypad manuals

NAPCO MAGNUM ALERT RP1000E LCD KEYPAD User manual

NAPCO

NAPCO MAGNUM ALERT RP1000E LCD KEYPAD User manual

NAPCO RP1054e User manual

NAPCO

NAPCO RP1054e User manual

NAPCO RP1054e User manual

NAPCO

NAPCO RP1054e User manual

NAPCO Gemini GEM-RP3DGTL User manual

NAPCO

NAPCO Gemini GEM-RP3DGTL User manual

NAPCO RPXP6GT User manual

NAPCO

NAPCO RPXP6GT User manual

NAPCO RP1016LCD User manual

NAPCO

NAPCO RP1016LCD User manual

NAPCO MAGNUM ALERT RP3000 KEYPAD User manual

NAPCO

NAPCO MAGNUM ALERT RP3000 KEYPAD User manual

NAPCO RP1054D KEYPAD User manual

NAPCO

NAPCO RP1054D KEYPAD User manual

NAPCO Gemini GEM-K3DGTL User manual

NAPCO

NAPCO Gemini GEM-K3DGTL User manual

NAPCO RP1054e User manual

NAPCO

NAPCO RP1054e User manual

NAPCO Magnum Alert User manual

NAPCO

NAPCO Magnum Alert User manual

NAPCO Gemini GEM-RP4C User manual

NAPCO

NAPCO Gemini GEM-RP4C User manual

NAPCO MAGNUM ALERT RP3000 KEYPAD User manual

NAPCO

NAPCO MAGNUM ALERT RP3000 KEYPAD User manual

NAPCO RP1054e User manual

NAPCO

NAPCO RP1054e User manual

NAPCO Magnum Alert RP2000LCD User manual

NAPCO

NAPCO Magnum Alert RP2000LCD User manual

NAPCO Gemini GEM-RP1CAe2 User manual

NAPCO

NAPCO Gemini GEM-RP1CAe2 User manual

NAPCO GEM-RP1CAE KEYPAD User manual

NAPCO

NAPCO GEM-RP1CAE KEYPAD User manual

NAPCO MAGNUM ALERT RP2000 KEYPAD User manual

NAPCO

NAPCO MAGNUM ALERT RP2000 KEYPAD User manual

NAPCO RP1016LCD User manual

NAPCO

NAPCO RP1016LCD User manual

NAPCO Gemini GEM-TOUCH K Series User manual

NAPCO

NAPCO Gemini GEM-TOUCH K Series User manual

NAPCO Gemini GEM-K4 User manual

NAPCO

NAPCO Gemini GEM-K4 User manual

NAPCO MAGNUM ALERT RP1016 LCD KEYPAD User manual

NAPCO

NAPCO MAGNUM ALERT RP1016 LCD KEYPAD User manual

NAPCO MAGNUM ALERT RP1016E KEYPAD User manual

NAPCO

NAPCO MAGNUM ALERT RP1016E KEYPAD User manual

NAPCO GEM-RP2AS User manual

NAPCO

NAPCO GEM-RP2AS User manual

Popular Keypad manuals by other brands

Harman Kardon KP 1 Specifications

Harman Kardon

Harman Kardon KP 1 Specifications

Toshiba RKP007Z user manual

Toshiba

Toshiba RKP007Z user manual

Clare Controls ClareOne CLR-C1-PNC Installation sheet

Clare Controls

Clare Controls ClareOne CLR-C1-PNC Installation sheet

Dynex DX-KEYPAD Quick setup guide

Dynex

Dynex DX-KEYPAD Quick setup guide

Bosch FMR-7036 manual 

Bosch

Bosch FMR-7036 manual 

Targus Stow-N-Go AKP01US user guide

Targus

Targus Stow-N-Go AKP01US user guide

Clare Controls ClareVue 5 Replacement manual

Clare Controls

Clare Controls ClareVue 5 Replacement manual

DMP Electronics 791 Easy Entry Installation sheet

DMP Electronics

DMP Electronics 791 Easy Entry Installation sheet

RIDGE RESKEY 14-RK10 quick start guide

RIDGE RESKEY

RIDGE RESKEY 14-RK10 quick start guide

Universal Remote Control Total Control TKP-7000 owner's manual

Universal Remote Control

Universal Remote Control Total Control TKP-7000 owner's manual

Velleman HAA2850 user manual

Velleman

Velleman HAA2850 user manual

CAMDEN CV-6268W installation instructions

CAMDEN

CAMDEN CV-6268W installation instructions

AMX DAS-MET-NUM Dimensional drawing

AMX

AMX DAS-MET-NUM Dimensional drawing

International Electronics Oracle OWK5 manual

International Electronics

International Electronics Oracle OWK5 manual

YASKAWA JVOP-KPLCB04AxB installation manual

YASKAWA

YASKAWA JVOP-KPLCB04AxB installation manual

Genovation v0.73 user guide

Genovation

Genovation v0.73 user guide

Targus Numeric Keypad with 2 USB ports user guide

Targus

Targus Numeric Keypad with 2 USB ports user guide

Extel KLAVY NAC-100 Installation and user guide

Extel

Extel KLAVY NAC-100 Installation and user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.