manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OBERON
  6. •
  7. Rack & Stand
  8. •
  9. OBERON 1013-00 User manual

OBERON 1013-00 User manual

Installation Guide / Guía de instalación
for Oberon Model 1013-00 & 33-1013-COVER
para Modelo Oberon 1013-00 & 33-1013-COVER
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1 -2022 Oberon Incorporated. All rights reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1 -2022 Oberon Incorporated. Todos los derechos reserve.
EPN 2242 & 2387 - Rev. 1/26/2022
The model 1013 is a 2-axis articulating wall mount for most manufacturers’ APs
and directive (or patch) antennas. AP and directional antenna attach to this
mount, and the antenna can be pointed in any direction to achieve desired
wireless coverage. Wall mount bracket can be placed directly over data outlet.
Designed for Cisco and Aruba Networks APs and directive antenna, and many
other vendors’ APs. Ideal for classrooms, auditoriums, and stadiums where
directional coverage is required.
El modelo 1013 es un soporte de pared articulado de 2 ejes para la mayoría de
los AP y antenas directivas (o parches) de los fabricantes. El AP y la antena
direccional se conectan a este soporte, y la antena se puede apuntar en
cualquier dirección para lograr la cobertura inalámbrica deseada. El soporte de
montaje en pared se puede colocar directamente sobre la salida de datos.
Diseñado para Cisco y Aruba Networks APs y antena directiva, y AP de mu-
chos otros proveedores. Ideal para aulas, auditorios y estadios donde se
requiere cobertura direccional.
Instructions are for typical install conditions. Instructions may not be
correct for all installations due to building design, construction ma-
terials or methods used and/or building or site conditions. Consult a
contractor or architect for recommendations. For product questions
call (+1) 877-867-2312.
Las instrucciones son para condiciones típicas de instalación. Las
instrucciones pueden no ser correctas para todas las instalaciones
según el diseño del edificio, materiales de construcción o métodos
utilizados, o condiciones del edificio o del lugar. Consulte a un con-
tratista o arquitecto para obtener recomendaciones. Si tiene
preguntas con respecto al producto, llame al (+1) 877-867-2312.
Thank you for choosing Oberon. / Gracias por elegir Oberon.
WARNING / ADVERTENCIA
Follow manufacturer's instructions for hand or ower tools.
Always use safety glasses. Failure to do so may result in injury
and/or roduct damage.
Siga las instrucciones del fabricante ara herramientas manu-
ales o eléctricas. Utilice siem re gafas de seguridad. Si no lo
hace, odría roducirse lesiones y / o daños al roducto.
WARNING / ADVERTENCIA
Use caution when working at elevated heights. Follow manu-
facturer's instructions for laddors and/or scaffolding. Failure to
do so may result in injury or death.
Tenga cuidado al trabajar a alturas elevadas y alrededor de las
aberturas de la unidad. Siga las instrucciones del fabricante
ara laddors y / o andamios. Si no lo hace, odría causar le-
siones o la muerte.
Im ortant Information for Model 1013 / Información im ortante ara el modelo 1013
1. Always consider potential hazards to others around you.
2. During installation, use warning signs, etc.
3. Be sure to securely fasten the mount to the wall to prevent it from becoming dislodged.
4. This product is intended to be installed by trained personnel.
5. AC Power is not to be used to power attached equipment.
1. Considere siempre el peligro potencial para quienes lo rodean.
2. Durante la instalación, utilice las señales de advertencia y demás señales.
3. Asegúrese de sujetar firmemente el soporte a la pared para evitar que se desprenda.
4. Este producto debe ser instalado por personal capacitado.
5. La alimentación de CA no se debe utilizar para alimentar equipos conectados.
Important code and installation information. / Información importante
sobre normas e instalación.
Read guide from beginning to end before beginning installation. Read
all warnings and cautions before beginning unit installation. Check with
your local building code official to identify and confirm compliance with
local building code requirements. This installation guide covers in-
stalling your Model 1013 in a typical environment. The appropriate
method for your installation may vary based on building design, appli-
cation, and industry practices.
Lea la guía de principio a fin antes de comenzar la instalación. Lea
todas las advertencias y precauciones antes de comenzar la in-
stalación de la unidad. Verifique con un oficial de código edilicio de su
localidad para identificar y confirmar el cumplimiento con los requisitos
locales del código de edificación. Esta guía de instalación cubre la
instalación del Modelo 1013 en un entorno adecuado. El método
apropiado para la instalación puede variar según el diseño del edificio,
la aplicación y las prácticas de la industria.
Tools Needed / Herramientas necesarias
None (for 33-1013-COVER SKU Only) / Ninguna (solo para SKU 33-1013-COVER)
Phillips-Head Screwdriver / Destornillador Phillips
Drill with a bit corresponding to the size of the mounting hardware to be used /
Taladre con una broca correspondiente al tamaño del hardware de montaje que se utilizará
4 (2 minimum) #10 x 2” screws (if mounting to a stud) /
4 (2 mínimo) tornillos #10 x 2" (si se monta en un perno)
4 suitable wall anchors (if not mounting to a stud) /
4 anclajes de pared adecuados (si no se montan en un montante)
Estimated Installation Time:
Tiempo Estimado de Instalación:
10m (for 1013-00 SKU Only) / (solo para SKU 1013-00)
2m (for 33-1013-COVER SKU Only) / (solo para SKU 33-1013-COVER)
(1) Antenna/AP Mounting Plate / Placa de montaje de antena/AP
(1) Articulating Bracket / Soporte articulado
(1) T-Bar Bracket / Soporte de la barra en T
(2) #6-32 x 3/16” Pan Head Screws / Tornillos de cabeza plana #6-32 x 3/16"
(6) #6-32 x 1/4” Pan Head Screws / Tornillos de cabeza plana #6-32 x 1/4"
(4) #6-32 x 1/2” Pan Head Screws / Tornillos de cabeza plana #6-32 x 1/2"
(4) #8-32 x 3/16” Pan Head Screws / Tornillos de cabeza plana #8-32 x 3/16"
(2) #8-32 x 7/16” Flat Head Screws / Tornillos de cabeza plana #8-32 x 7/16"
(4) #8-32 x 5/8” Pan Head Screws / Tornillos de cabeza plana #8-32 x 5/8"
(2) Cable Ties / Brida de cables
(4) Adhesive Backed Mushroom-Head Fasteners / Sujetadores de cabeza de
hongo con reverso adhesivo
Parts Included (for 1013-00 SKU Only) /
Partes Incluidas / (solo para SKU 1013-00)
(1) Dome / Domo
Parts Included (for 33-1013-COVER SKU Only) /
Partes Incluidas (solo para SKU 33-1013-COVER)
Installation Guide / Guía de instalación
for Oberon Model 1013-00 & 33-1013-COVER
para Modelo Oberon 1013-00 & 33-1013-COVER
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1 -2022 Oberon Incorporated. All rights reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1 -2022 Oberon Incorporated. Todos los derechos reserve.
EPN 2242 & 2387 - Rev. 1/26/2022
Mark the screw hole locations on the wall using the included template or the
Model 1013 itself. The mount can be conveniently installed directly over a
telecommunications outlet. It is recommended that the mount be fastened to
a stud if possible.
Pre-drill the marked screw hole locations. Use a minimum of two (2) #10 x
2” or larger screws (not included) to secure the mount to a stud. If there is
no stud at the mounting location, use four (4) wall anchors suitable for the
wall construction, such as threaded drywall anchors, threaded drywall tog-
gles, sleeve type hollow wall anchors (a.k.a. Molly Bolts) or toggle bolts.
There should be enough clearance between the bottom of the screw head
and the wall for the keyhole slots in the mount to engage the screws. Due to
the weight of the AP, AP antenna, and mount, plastic wall anchors are not
recommended for fastening the mount to the wall.
If not using a Cisco or Meraki AP mounting bracket, attach the T-bar bracket
to the articulating bracket with two (2) of the included #6-32 x 1/4" screws
(see image above).
Slide the mount over the screw heads through the keyhole slots and finish
securing the mount.
Marque las ubicaciones de los orificios para tornillos en la pared utilizando
la plantilla incluida o el Modelo 1013 en sí. El soporte se puede instalar
convenientemente directamente sobre una toma de telecomunicaciones. Se
recomienda que el soporte se sujete a un perno si es posible.
Pretaladre las ubicaciones marcadas de los orificios para tornillos. Use un
mínimo de dos (2) tornillos #10 x 2” o más grandes (no incluidos) para
asegurar el montaje a un perno. Si no hay un montante en el lugar de mon-
taje, use cuatro (4) anclajes de pared adecuados para la construcción de la
pared, tales como anclajes de paneles de yeso roscados, alternadores de
paneles de yeso roscados, anclajes de pared huecos tipo manga (también
conocidos como tornillos Molly) o pernos de palanca. Debe haber suficiente
espacio entre la parte inferior de la cabeza del tornillo y la pared para que
las ranuras del ojo de la cerradura en el soporte encajen en los tornillos.
Debido al peso del AP, la antena AP y el soporte, no se recomiendan los
anclajes plásticos de pared para fijar el soporte a la pared.
Si no usa un soporte de montaje Cisco o Meraki AP, fije el soporte de barra
en T al soporte articulado con dos (2) de los tornillos #6-32 x 1/4" incluidos
(vea la imagen de arriba).
Deslice el soporte sobre las cabezas de los tornillos a través de las ranuras
de ojo de cerradura y termine de asegurar el soporte. Apriete los tornillos
del soporte articulado en la posición deseada.
1
(Cisco and Meraki APs Only) Use the mounting plate legend on page 1
to determine which hole pattern to use. Securely fasten the access
point’s mounting bracket to the back side of the Antenna Mounting Plate,
the side with the press nuts, using the required hardware. For Cisco APs,
use the four (4) included #8-32 x 3/16" screws. For Meraki APs, use the
two (2) included #6-32 x 3/16” screws.
(Solo AP Cisco y Meraki) Use la leyenda de la placa de montaje en la
página 1 para determinar qué patrón de agujeros usar. Fije de forma
segura el soporte de montaje del punto de acceso a la parte posterior de
la placa de montaje de la antena, el lado con las tuercas a presión,
usando la tornillería necesaria. Para los puntos de acceso de Cisco, use
los cuatro (4) tornillos incluidos #8-32 x 3/16". Para los puntos de acceso
Meraki, use los dos (2) tornillos incluidos #6-32 x 3/16".
Attach the Antenna Mounting Plate to the articulating mount using the
two (2) included #8-32 x 7/16" flat head screws. The Antenna Mounting
Plate should be oriented so that the back side of the plate with the press
nuts is facing towards the wall (see image above).
Fije la placa de montaje de la antena al soporte de articulación utilizando
los dos (2) tornillos de cabeza plana #8-32 x 7/16” incluidos. La placa de
montaje de la antena debe estar orientada de manera que el lado poste-
rior de la placa con las tuercas de presión quede orientada hacia la
pared (ver imagen arriba).
If not already done, partially thread a #6-32 x 1/4” screw into each of the
four (4) threaded holes on the center joint of the articulating mount to use as
set screws.
NOTE: The mount should still be able to freely articulate along the X and Y
axis. If there is any additional resistance or if the mount cannot articulate,
back off some of the screws a few turns and try again.
Articulate the mount to position the antenna at the desired angle. Make sure
that the partially threaded screws will align with one of the locking holes on
the center joint.
With the mount in the desired position, tighten the four (4) set screws to
secure the mount’s angle and prevent movement.
(O tional) Use the provided cable ties to secure the antenna cables to the
mount.
Si aún no lo ha hecho, enrosque parcialmente un tornillo #6-32 x 1/4” en
cada uno de los cuatro (4) orificios roscados en la junta central del soporte
articulado para usar como tornillos de fijación.
NOTA: La montura aún debe poder articularse libremente a lo largo de los
ejes X e Y. Si hay alguna resistencia adicional o si la montura no se puede
articular, afloje algunos de los tornillos unas cuantas vueltas y vuelva a
intentarlo.
Articule el soporte para colocar la antena en el ángulo deseado. Asegúrese
de que los tornillos parcialmente roscados se alineen con uno de los orifi-
cios de bloqueo en la junta central.
Con el soporte en la posición deseada, apriete los cuatro (4) tornillos de
fijación para asegurar el ángulo del soporte y evitar el movimiento.
(O cional) Use las bridas para cables provistas para asegurar los cables
de la antena al soporte.
Run the data and power cable (if required) to the access point.
The 1013-00 installation is now complete.
Ejecute los datos y el cable de alimentación (si es necesario) al punto de
acceso.
La instalación de 1013-00 ahora está completa.
2a
3
Use the mounting plate legend on the page 1 to determine which hole
pattern to use for antenna attachment. Use #8-32 x 5/8" screws to attach
Cisco antennas and #6-32 x 1/2" screws for Aruba Antennas. If no hole
pattern is feasible, use the four (4) included adhesive backed mushroom-
head fasteners to adhere the antenna to the Antenna Mounting Plate. To
do this, first peal one (1) side of each fastener and apply to the clean
backside surface of the antenna. Then peal the other side of each fas-
tener and adhere the Antenna to the Antenna Mounting Plate.
Use la leyenda de la placa de montaje en la página 1 para determinar
qué patrón de agujeros usar para la conexión de la antena. Use tornillos
#8-32 x 5/8" para conectar antenas Cisco y tornillos #6-32 x 1/2" para
antenas Aruba. Si no es factible un patrón de orificios, use los cuatro (4)
sujetadores de cabeza de hongo con reverso adhesivo incluidos para
adherir la antena a la placa de montaje de la antena. Para hacer esto,
primero despegue un (1) lado de cada sujetador y aplíquelo a la superfi-
cie trasera limpia de la antena. Luego pele el otro lado de cada sujetador
y adhiera la antena a la placa de montaje de la antena.
45
6
(Aruba and Other APs) Attach the T-bar clip to the T-bar bracket per the
Access Point Manufacturer's instructions.
(Aruba y otros AP) Conecte el clip de la barra en T al soporte de la
barra en T según las instrucciones del fabricante del punto de acceso.
2b
**IMPORTANT** - It is important that the mount is se-
curely fastened to the wall or ceiling to prevent human inju-
ry or damage to the access point
**IMPORTANTE** - Es importante que el soporte esté
bien sujeto a la pared o al techo para evitar lesiones hu-
manas o daños al punto de acceso
Installation Guide / Guía de instalación
for Oberon Model 1013-00 & 33-1013-COVER
para Modelo Oberon 1013-00 & 33-1013-COVER
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1 -2022 Oberon Incorporated. All rights reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1 -2022 Oberon Incorporated. Todos los derechos reserve.
EPN 2242 & 2387 - Rev. 1/26/2022
7
NOTE: The 33-1013-COVER is an optional accessory for the 1013-00.
To attach the 33-1013-COVER, place one of the slotted outer edges of the
plastic dome over the extended tab located on the edge of the mounting
plate. Gently pull the opposite slotted edge over the tab on the other side of
the mounting plate of the 1013-00, as shown above.
The 33-1013-COVER installation is now complete.
NOTA: El 33-1013-COVER es un accesorio opcional para el 1013-00.
Para colocar el 33-1013-COVER, coloque uno de los bordes exteriores
ranurados del domo de plástico sobre la pestaña extendida ubicada en el
borde de la placa de montaje. Tire suavemente del borde ranurado opuesto
sobre la pestaña en el otro lado de la placa de montaje del 1013-00, como
se muestra arriba.
La instalación de 33-1013-COVER ahora está completa.

This manual suits for next models

1

Other OBERON Rack & Stand manuals

OBERON 1040-CCOAP3800 Operating and maintenance instructions

OBERON

OBERON 1040-CCOAP3800 Operating and maintenance instructions

OBERON 1016-ANTPLATE Series User manual

OBERON

OBERON 1016-ANTPLATE Series User manual

OBERON 1042-FL User manual

OBERON

OBERON 1042-FL User manual

OBERON 1064-00 User manual

OBERON

OBERON 1064-00 User manual

OBERON Skybar 3001-00 Series User manual

OBERON

OBERON Skybar 3001-00 Series User manual

OBERON Aruba Series User manual

OBERON

OBERON Aruba Series User manual

OBERON NetPoint 3032 Series User manual

OBERON

OBERON NetPoint 3032 Series User manual

OBERON 1006-MIST43 User manual

OBERON

OBERON 1006-MIST43 User manual

OBERON Aruba 1044-ARAP5 Series User manual

OBERON

OBERON Aruba 1044-ARAP5 Series User manual

OBERON Aruba 1042-ARAP5 Series User manual

OBERON

OBERON Aruba 1042-ARAP5 Series User manual

OBERON 950-AP303 User manual

OBERON

OBERON 950-AP303 User manual

OBERON 39-1020-PMK User manual

OBERON

OBERON 39-1020-PMK User manual

OBERON 1074-SC-6-ANT User manual

OBERON

OBERON 1074-SC-6-ANT User manual

OBERON 39-1008-SPKRMNT User manual

OBERON

OBERON 39-1008-SPKRMNT User manual

OBERON 39-1015-RAB User manual

OBERON

OBERON 39-1015-RAB User manual

OBERON 1006-CCOAP User manual

OBERON

OBERON 1006-CCOAP User manual

OBERON 1042-CCOAP3800 User manual

OBERON

OBERON 1042-CCOAP3800 User manual

OBERON 1043-ARAP5 Series User manual

OBERON

OBERON 1043-ARAP5 Series User manual

OBERON 1021-00-ANTPLATE User manual

OBERON

OBERON 1021-00-ANTPLATE User manual

OBERON 1044-CCOAP3800-B User manual

OBERON

OBERON 1044-CCOAP3800-B User manual

OBERON 1012-00 User manual

OBERON

OBERON 1012-00 User manual

OBERON 1042-MIST43 User manual

OBERON

OBERON 1042-MIST43 User manual

OBERON 1020-00-USM30 User manual

OBERON

OBERON 1020-00-USM30 User manual

Popular Rack & Stand manuals by other brands

3Com 350 Series installation guide

3Com

3Com 350 Series installation guide

ICAROS Tablet Holder Universal Installation

ICAROS

ICAROS Tablet Holder Universal Installation

StarTech.com A-LAPTOP-DESK-MOUNT user manual

StarTech.com

StarTech.com A-LAPTOP-DESK-MOUNT user manual

Sealey STR004.V3 instructions

Sealey

Sealey STR004.V3 instructions

Vallox 096 MC R installation instructions

Vallox

Vallox 096 MC R installation instructions

Monster SUPERTHIN MEDIUM PIVOT MOUNT Installation manual and warranty

Monster

Monster SUPERTHIN MEDIUM PIVOT MOUNT Installation manual and warranty

TAUBENREUTHER 1-25937 FITTING INSTRUCTION

TAUBENREUTHER

TAUBENREUTHER 1-25937 FITTING INSTRUCTION

Sukup TM05601 installation manual

Sukup

Sukup TM05601 installation manual

Strong SR-WM-SK-19 install guide

Strong

Strong SR-WM-SK-19 install guide

Belkin F1DN-MOD-MOUNT Quick installation guide

Belkin

Belkin F1DN-MOD-MOUNT Quick installation guide

Shure UA507 instructions

Shure

Shure UA507 instructions

Konig & Meyer 28070 manual

Konig & Meyer

Konig & Meyer 28070 manual

delight 39691 Installation

delight

delight 39691 Installation

PEERLESS IM760P Installation and assembly

PEERLESS

PEERLESS IM760P Installation and assembly

Chenbro RM23712 Technical manual

Chenbro

Chenbro RM23712 Technical manual

SMS SMS Flatscreen X FH M605 Motorized Instructions for mounting

SMS

SMS SMS Flatscreen X FH M605 Motorized Instructions for mounting

peerless-AV SMARTMOUNT XT STX650 manual

peerless-AV

peerless-AV SMARTMOUNT XT STX650 manual

Clarion HRM100 installation instructions

Clarion

Clarion HRM100 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.