Installation Guide / Guía de instalación
for Oberon Model 3032-00-XX
para Modelo Oberon 3032-00-XX
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1999-2020 Oberon Incorporated. All ri hts reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
Model 3032 - Rev. 8/2/2020
Oberon's NetPoint™ 3032 Wireless Bollard is a cost effective way to
extend wireless and Wi-Fi covera e into auditoriums, sports venues,
courtyards, malls, and campus open areas permanently or temporarily.
The Wireless bollard can be used to mount Wi-Fi APs and antennas in
locations where mountin on buildin s or li ht poles is aesthetically un-
acceptable. The bollard is desi ned to protect APs and antennas from
weather and tamperin . The polyethylene thermoplastic cylinder is virtu-
ally transparent to wireless si nal. Lar e enou h for APs, omni-
directional and directional antennas, and associated equipment from
most vendors.
El bolard NetPoint™ 3032 de Oberon es una forma rentable de extender
la cobertura inalámbrica y Wi-Fi en auditorios, instalaciones deportivas,
patios, centros comerciales y áreas abiertas del campus de forma per-
manente o temporal. El bolardo inalámbrico se puede utilizar para mon-
tar AP´s Wi-Fi y antenas en lu ares donde el montaje en edificios o
postes de luz es estéticamente inaceptable. El bolardo está diseñado
para prote er los AP y las antenas del clima y la manipulación. El
cilindro termoplástico de polietileno es prácticamente transparente a la
señal inalámbrica. Lo suficientemente rande para AP, antenas omnidi-
Instructions are for typical install conditions. Instructions may not be
correct for all installations due to buildin desi n, construction ma-
terials or methods used and/or buildin or site conditions. Consult a
contractor or architect for recommendations. For product questions
call (+1) 877-867-2312.
Las instrucciones son para condiciones típicas de instalación. Las
instrucciones pueden no ser correctas para todas las instalaciones
se ún el diseño del edificio, materiales de construcción o métodos
utilizados, o condiciones del edificio o del lu ar. Consulte a un con-
tratista o arquitecto para obtener recomendaciones. Si tiene
pre untas con respecto al producto, llame al (+1) 877-867-2312.
Thank you for choosin Oberon. / Gracias por ele ir Oberon.
WARNING / ADVERTENCIA
Follow manufacturer's instructions for hand or ower tools.
Always use safety glasses. Failure to do so may result in injury
and/or roduct damage.
Siga las instrucciones del fabricante ara herramientas manu-
ales o eléctricas. Utilice siem re gafas de seguridad. Si no lo
hace, odría roducirse lesiones y / o daños al roducto.
WARNING / ADVERTENCIA
Before digging, contact local underground utilities location
service by calling 811. Check for ossible gas lines, revious
underground electrical conduit, or other obstructions. Wear
ro er PPE and use a ro riate signage indicating the work-
s ace.
Antes de excavar, comuníquese con el servicio de localización
de servicios subterráneos locales llamando al 811. Verifique si
hay osibles líneas de gas, conductos subterráneos revios u
otras obstrucciones. Use un EPP a ro iado y use letreros
a ro iados que indiquen el es acio de trabajo.
Im ortant Information for Model 3032 / Información im ortante ara el modelo 3032
1. Always consider potential hazards to others around you.
2. Durin installation, use warnin si ns, etc.
3. Be sure to securely fasten the enclosure to prevent it from becomin dislod ed.
1. Considere siempre el peli ro potencial para quienes lo rodean.
2. Durante la instalación, utilice las señales de advertencia y demás señales.
3. Ase úrese de sujetar firmemente el abinete para evitar que se desprenda.
Important code and installation information. / Información im-
portante sobre normas e instalación.
Read uide from be innin to end before be innin installation. Read all
warnin s and cautions before be innin unit installation. Check with your
local buildin code official to identify and confirm compliance with local
buildin code requirements. This installation uide covers installin your
Model 3032 in a typical environment. The appropriate method for your
installation may vary based on buildin desi n, application, and industry
practices.
Lea la uía de principio a fin antes de comenzar la instalación. Lea todas
las advertencias y precauciones antes de comenzar la instalación de la
unidad. Verifique con un oficial de códi o edilicio de su localidad para
identificar y confirmar el cumplimiento con los requisitos locales del códi-
o de edificación. Esta uía de instalación cubre la instalación del
Modelo 3032 en un entorno adecuado. El método apropiado para la
instalación puede variar se ún el diseño del edificio, la aplicación y las
prácticas de la industria.
Tools Needed / Herramientas necesarias
• Phillips-Head Screwdriver / Destornillador Phillips
• Screw Gun or Drill / Distornillador electrico o taladro
• Wrench with 5/8” Socket / Matraca con dado de 5/8"
• Adjustable Wrench / Perico
Estimated Installation Time:
Tiempo Estimado de Instalación: 2 hrs
Parts Included / Partes Incluidas
(1) Polyurethane Bollard / Bolardo de poliuretano
(1) T-Bar Bracket / Soporte de barra en T
(1) Ri ht An le Bracket / Soporte de án ulo recto
(1) Cisco Mountin Bracket / Soporte de montaje de Cisco
(4) Black Snap-on Screw Caps / Tapones ne ros Snap On
(2) 1/4”-20 Tamper Resistant Screws / 1/4"-20 tornillos de se-
uridad
(3) #10-32 x 7/16” Flat Head Screws / #10-32 x 7/16" tornillos
de cabeza plana
(4) #8-32 x 1/4” Screws / #8 - 32 x 1/4” tornillos
(1) 1-1/4” Pole Fittin / 1-1/4" Montaje de rieles
(1) 5/32” Hex Pin In Bit / 5/32” Punta hexa onal
(2) 1-7/16” Clampin U-Bolt / 1-7/16" Perno en U de sujeción
Installation Guide / Guía de instalación
for Oberon Model 3032-00-XX
para Modelo Oberon 3032-00-XX
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1999-2020 Oberon Incorporated. All ri hts reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
Model 3032 - Rev. 8/2/2020
Di a hole at least 11.5” diameter minimum in the desired location for the assembly. The hole depth is determined by the frostline of the installation location.
30” is the minimum recommended. The sidewalls must be flush and plumb. Uneven sidewalls can cause the foundation to fail or tilt.
Cave un a ujero de al menos 11.5" mínimo en la ubicación deseada para el ensamblaje. La profundidad del pozo está determinada por la línea de hielo de la
ubicación de instalación. 30" es el mínimo recomendado. Las paredes laterales deben estar niveladas y a plomo. Los flancos desi uales pueden hacer que
la base falle o se incline.
1
Di the trench for layin conduit. Data and power cables must be separated when runnin conduit to the bollard. Place the conduit within the trench and up
throu h where the anchor base concrete will be poured.
Cave la zanja para colocar el conducto. Los cables de datos y alimentación deben estar separados cuando se conduce el conducto hacia el bolardo. Colo-
que el conducto dentro de la zanja y hacia arriba a través del lu ar donde se va a verter el hormi ón de la base del anclaje.
2
Follow local code requirements for buried conduit. Fill around the conduit with ravel if necessary. Mix and pour the concrete around the conduit. 3000 to
3500 psi concrete is recommended.
Llene alrededor del conducto con rava si es necesario. Mezcle y vierta el concreto alrededor del conducto. Se recomienda un concreto de 3000 a 3500 psi.
3
Usin the template, create a bolt positioner board to hold anchor bolts in place while the concrete sets and drill a center hole lar e enou h for conduit. Fasten
5/8” x 18” anchor bolts in a 8.5” diameter circle to the board usin 5/8” nuts and washers above and below, leavin 2.5” or reater above the board. Oberon’s
39-303X-FOOTING KIT includes a template, bolts, and hardware for anchor bolt positionin . The bolts must be ti ht to prevent them from mi ratin while
installin .
Usando la plantilla, crea una tabla de posicionadores de pernos para mantener los pernos de anclaje en su lu ar mientras se establece el concreto. Sujete
pernos de anclaje de 5/8" x 18" en un círculo de 8.5" de diámetro a la placa con tuercas y arandelas de 5/8" arriba y abajo, dejando 2,5" o más arriba del
tablero. KIT 39-303X-FOOTING de Oberon incluye una plantilla para el posicionamiento del perno de anclaje.
4
Limestone or other sand
Buried Electrical Cauon Flagging
Installation Guide / Guía de instalación
for Oberon Model 3032-00-XX
para Modelo Oberon 3032-00-XX
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1999-2020 Oberon Incorporated. All ri hts reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
Model 3032 - Rev. 8/2/2020
Press the anchor bolts into the wet concrete and vibrate to remove voids from around the anchor bolts and ed es of forms. Level the bolt positioner board
without pressin the bottom levelin nuts into the concrete. Cover and allow the concrete to set.
Presione los pernos de anclaje en el concreto húmedo y vibre para eliminar los huecos alrededor de los pernos de anclaje y los bordes. Nivele la placa del
posicionador de pernos sin presionar las tuercas de nivelación inferiores en el concreto. Cubra y permita que el concreto fra üe.
5
After the concrete has set, remove the bolt positioner board. Leave the lower nuts and washers in place for anchor base installation. Place the anchor base
over the nuts. Level the anchor base, then fasten with another set of nuts and washers. Pull the data and power cables throu h the conduit.
Después de colocar el concreto, remueva la plantilla. Enrosque las tuercas en los pernos de anclaje y coloque la base del anclaje sobre las tuercas. Nivele la
base del anclaje, lue o apriete con otro jue o de tuercas. Tire de los datos y los cables de alimentación a través del conducto.
6
Fasten the Aluminum Pole Flan e to the Anchor Base with the provided #10-32 Flat Head Screws. Slide the Fiber lass Pole into the Pole Flan e and ti hten
the set screw.
Sujete la brida de poste de aluminio a la base del anclaje con los tornillos de cabeza plana #10-32 proporcionados. Deslice el poste de fibra de vidrio en la
brida del poste y apriete el tornillo de fijación.
7
If mountin a Cisco Access Point, fasten the CCOAP Mountin Plate to the Fiber lass Pole usin the provided U-Bolts. Attach the Access Point and plu in
the cables.
Si monta un punto de acceso Cisco, sujete la placa de montaje CCOAP al poste de fibra de vidrio usando los pernos en U provistos. Conecte el punto de
acceso y conecte los cables.
8
Cisco
Bolt Posioner Board
Leveling Nuts and Washers
Installation Guide / Guía de instalación
for Oberon Model 3032-00-XX
para Modelo Oberon 3032-00-XX
Mounting Solutions for WiFi Access Points
"Oberon" and all other marks where denoted are trademarks of Oberon Inc. ©1999-2020 Oberon Incorporated. All ri hts reserved.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
Model 3032 - Rev. 8/2/2020
Place the Bollard over the equipment stand and fasten to the anchor base usin the included 1/4”-20 tamper resistant screws and screw caps with the provid-
ed pin in hex bit. The bollard may be fastened to the lower set of holes on the anchor base to recess into the round or cover excess hardware.
The Installation is now complete.
Coloque el Bolardo sobre el soporte del equipo y sujételo a la base del anclaje utilizando los tornillos de se uridad de 1/4"-20 incluidos y las tapas de rosca
con la punta hexa onal. El bolardo se debe sujetar al conjunto inferior de orificios en la base del anclaje para encajar en el suelo o cubrir el exceso de hard-
ware.
La instalación está completa.
11
If mountin to the ri ht-an le bracket, fasten the bracket to the Fiber lass Pole usin the provided U-Bolts. Attach the Cisco AIR-BRACKET usin the includ-
ed #8-32 Screws then mount the Cisco AP to the Cisco bracket. The Fiber lass Pole may need to be trimmed. Once the access point is attached, plu in the
cables.
Si se monta en el soporte en án ulo recto, fije el soporte al poste de fibra de vidrio con los pernos en U provistos. Fije el SOPORTE DE AIRE Cisco utilizan-
do los Tornillos # 8-32 incluidos, lue o monte el AP de Cisco en el soporte de Cisco. El poste de fibra de vidrio puede necesitar ser recortado. Una vez que el
punto de acceso está conectado, conecte los cables.
9
For the Aruba 270, 370, and 570 Series APs, fasten the R/A bracket to the Fiber lass Pole usin the provided U-Bolts. Top of the R/A bracket usin the in-
cluded 1/4” - 20 Screws. The Fiber lass Pole may need to be trimmed. Once the access point is attached, plu in the cables.
Para los AP Aruba 270, 370 y 570 Series, fije el soporte R / A al poste de fibra de vidrio con los pernos en U provistos. Parte superior del soporte R / A con
los tornillos incluidos 1/4 ”- 20. El poste de fibra de vidrio puede necesitar ser recortado. Una vez que el punto de acceso está conectado, conecte los cables.
10
Cisco
Aruba

Other OBERON Rack & Stand manuals

OBERON 1040-CCOAP3800 Operating and maintenance instructions

OBERON

OBERON 1040-CCOAP3800 Operating and maintenance instructions

OBERON 1042-FL User manual

OBERON

OBERON 1042-FL User manual

OBERON 1006-MIST43 User manual

OBERON

OBERON 1006-MIST43 User manual

OBERON Aruba 1042-ARAP5 Series User manual

OBERON

OBERON Aruba 1042-ARAP5 Series User manual

OBERON 1042-CCOAP3800 User manual

OBERON

OBERON 1042-CCOAP3800 User manual

OBERON 39-1008-SPKRMNT User manual

OBERON

OBERON 39-1008-SPKRMNT User manual

OBERON 1021-00-ANTPLATE User manual

OBERON

OBERON 1021-00-ANTPLATE User manual

OBERON Aruba 1044-ARAP5 Series User manual

OBERON

OBERON Aruba 1044-ARAP5 Series User manual

OBERON 1020-00-USM30 User manual

OBERON

OBERON 1020-00-USM30 User manual

OBERON 1044-CCOAP3800-B User manual

OBERON

OBERON 1044-CCOAP3800-B User manual

OBERON 1074-SC-6-ANT User manual

OBERON

OBERON 1074-SC-6-ANT User manual

OBERON 1012-00 User manual

OBERON

OBERON 1012-00 User manual

OBERON 1042-MIST43 User manual

OBERON

OBERON 1042-MIST43 User manual

OBERON 39-1015-RAB User manual

OBERON

OBERON 39-1015-RAB User manual

OBERON Aruba Series User manual

OBERON

OBERON Aruba Series User manual

OBERON 1013-00 User manual

OBERON

OBERON 1013-00 User manual

OBERON 39-1020-PMK User manual

OBERON

OBERON 39-1020-PMK User manual

OBERON 1016-ANTPLATE Series User manual

OBERON

OBERON 1016-ANTPLATE Series User manual

OBERON Skybar 3001-00 Series User manual

OBERON

OBERON Skybar 3001-00 Series User manual

OBERON 1043-ARAP5 Series User manual

OBERON

OBERON 1043-ARAP5 Series User manual

OBERON 950-AP303 User manual

OBERON

OBERON 950-AP303 User manual

OBERON 1006-CCOAP User manual

OBERON

OBERON 1006-CCOAP User manual

OBERON 1064-00 User manual

OBERON

OBERON 1064-00 User manual

Popular Rack & Stand manuals by other brands

3Com 350 Series installation guide

3Com

3Com 350 Series installation guide

ICAROS Tablet Holder Universal Installation

ICAROS

ICAROS Tablet Holder Universal Installation

StarTech.com A-LAPTOP-DESK-MOUNT user manual

StarTech.com

StarTech.com A-LAPTOP-DESK-MOUNT user manual

Sealey STR004.V3 instructions

Sealey

Sealey STR004.V3 instructions

Vallox 096 MC R installation instructions

Vallox

Vallox 096 MC R installation instructions

Monster SUPERTHIN MEDIUM PIVOT MOUNT Installation manual and warranty

Monster

Monster SUPERTHIN MEDIUM PIVOT MOUNT Installation manual and warranty

TAUBENREUTHER 1-25937 FITTING INSTRUCTION

TAUBENREUTHER

TAUBENREUTHER 1-25937 FITTING INSTRUCTION

Sukup TM05601 installation manual

Sukup

Sukup TM05601 installation manual

Strong SR-WM-SK-19 install guide

Strong

Strong SR-WM-SK-19 install guide

Belkin F1DN-MOD-MOUNT Quick installation guide

Belkin

Belkin F1DN-MOD-MOUNT Quick installation guide

Shure UA507 instructions

Shure

Shure UA507 instructions

Konig & Meyer 28070 manual

Konig & Meyer

Konig & Meyer 28070 manual

delight 39691 Installation

delight

delight 39691 Installation

PEERLESS IM760P Installation and assembly

PEERLESS

PEERLESS IM760P Installation and assembly

Chenbro RM23712 Technical manual

Chenbro

Chenbro RM23712 Technical manual

SMS SMS Flatscreen X FH M605 Motorized Instructions for mounting

SMS

SMS SMS Flatscreen X FH M605 Motorized Instructions for mounting

peerless-AV SMARTMOUNT XT STX650 manual

peerless-AV

peerless-AV SMARTMOUNT XT STX650 manual

Clarion HRM100 installation instructions

Clarion

Clarion HRM100 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.