3E2AG
Specifications
Item M8 M12 M18 M30
Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
E2AG-
S08KS01-@-B1
E2AG-
S08KS01-@-B2
E2AG-
S08KN02-@-B1
E2AG-
S08KN02-@-B2
E2AG-
M12KS02-@-B1
E2AG-
M12KS02-@-B2
E2AG-
M12KN05-@-B1
E2AG-
M12KN05-@-B2
E2AG-
M18KS05-@-B1
E2AG-
M18KS05-@-B2
E2AG-
M18KN10-@-B1
E2AG-
M18KN10-@-B2
E2AG-
M30KS10-@-B1
E2AG-
M30KS10-@-B2
E2AG-
M30KN18-@-B1
E2AG-
M30KN18-@-B2
Sensing
distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Differential travel 10% max. of sensing distance
Detectable
object Ferrous metal (The sensing distance decrease with non-ferrous metal. Refer to Engineering Data on pages 4 and 5)
Standard
sensing object
Iron
8×8×1 mm
Iron
12×12×1 mm
Iron
15×15×1 mm
Iron
18×18×1 mm
Iron
30×30×1 mm
Iron
54×54×1 mm
Response
frequency*1
*1. The response frequency is an average value. Measurement conditions are as follows:standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
1 kHz 0.4 kHz 0.8 kHz 0.1 kHz 0.5 kHz 0.1 kHz 0.1 kHz 0.1 kHz
Power supply
voltage
(operating
voltage range)
12 to 24 VDC. Ripple(p-p):10% max.
(10~30 VDC)
Current
consumption 13 mA max.
Control
output
Load
current open collector, 200 mA max.
Residual
voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (yellow)
Operation mode
(with sensing
object
approaching)
B1 Models: NO
B2 Models: NC
Refer to the timing charts under Output Circurt Diagrams of page 7 for details.
Protection
circuits Reverse polarity protection,Surge suppressor,Load short-circurt protection
Ambient
temperature
range
Operating / Storage: -25~+70°C (with no icing or condensation)
Ambient
humidity range Operating / Storage: 35~95% RH
Voltage
influence ±10% max. of sensing distance in rated voltage range ±15%
Insulation
resistance 50 MΩmin. (at 500 VDC) between current carry parts and case
Dielectric
strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration
resistance 10~55 Hz 0.75 mm double amplitude for 2 hours each in X,Y,and Z directions
Shock
resistance
500 m/s² 10 times
each in X,Y,and Z directions 1,000 m/s² 10 times each in X,Y,and Z directions
Degree of
protection IEC 60529 IP67
Connection
method Pre-wired models (Standard cable length: 2 m)
Weight Approx. 55 g Approx. 65 g Approx. 140 g Approx. 190 g
Materials
Case Stainless steel (SUS303) Nickel plated brass
Sensing
surface PBT