Omron H7CX Series User manual

4
H7CXMultifunction Preset Counter
■Highly visible display with backlit negative trans-
missive LCD.
■Programmable PV color to visually alert when out-
put status changes (screw terminal block models).
■Intuitive setting enabled using ergonomic up/down
digit keys (4-digit models) and DIP switch.
■Configurable as 1-stage counter, 2-stage counter,
total and preset counter, batch counter, dual
counter, or tachometer. (Configurability varies with
model.)
■PNP/NPN switchable input.
■Finger-safe terminals (screw terminal block mod-
els).
■Meets a variety of mounting requirements:
Screw terminal block models, and pin-style termi-
nal models.
■NEMA4/IP66 compliance.
■Six-language instruction manual.
Contents
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Setting Procedure Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Operation (Counter Function) . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operation (Tachometer Function) . . . . . . . . . . . . . . . . . . . . . . . 25
Operation in Configuration Selection Mode. . . . . . . . . . . . . . . . 31
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Accessories (Order Separately) . . . . . . . . . . . . . . . . . . . . . . . . 37
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

5
H7CXH7CX
Ordering Information
Note: Can be used as a 2-stage counter. In this case, each output can be flexibly allocated to either stage 1 or 2.
■Model Number Legend:
1. External connection
None: Screw terminals
11: 11-pin socket
2. No. of digits
None: 6 digits
4: 4 digits
3. Stage setting
None: 1-stage setting
U: Factory-set to 1-stage setting
W: Factory-set to 2-stage setting
4. Output type
None: Contact output or contact and transistor in
combination
S: Transistor output
5. Supply voltage/external power supply
None: 100 to 240 VAC at 50/60 Hz with 12 VDC power
supply
D: 12 to 24 VDC without external power supply
D1: 12 to 24 VDC or 24 VAC at 50/60 Hz with 12 VDC
power supply
6. Case color
None: Black
G: Light gray (Munsell 5Y7/1): Produced upon request.
■Accessories (Order Separately)
Note: 1. Supplied with screw-terminal models (i.e., excluding H7CX-A11@/-A114@models).
2. Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket.
Supported configurations • 1-stage counter
• 1-stage counter with total counter • 1-stage counter
• 2-stage counter
• 1-stage counter with total
counter
• 1-stage counter with batch
counter
• Dual counter
• Tachometer
• 1-stage counter
• 2-stage counter
• 1-stage counter
with total counter
• 1-stage counter
with batch counter
• Dual counter
Sensor
power
supply
Output type Supply voltage 11-pin socket Screw terminal
1-stage 1-stage
(See note.) 2-stage
6 digits 4 digits 6 digits 4 digits 6 digits 6 digits 4 digits
H7CX-A11@H7CX-A114@H7CX-A@H7CX-A4@H7CX-AU@H7CX-AW@H7CX-A4W@
12 VDC Contact output 100 to 240 VAC H7CX-A11 H7CX-A114 H7CX-A H7CX-A4 --- H7CX-AW H7CX-A4W
12 to 24 VDC/
24 VAC H7CX-A11D1 H7CX-A114D1 --- --- --- H7CX-AWD1 ---
Contact and
transistor output 100 to 240 VAC --- --- --- --- H7CX-AU --- ---
12 to 24 VDC/
24 VAC --- --- --- --- H7CX-AUD1 --- ---
Transistor output 100 to 240 VAC H7CX-A11S H7CX-A114S H7CX-AS H7CX-A4S --- H7CX-AWS ---
12 to 24 VDC/
24 VAC H7CX-A11SD1 --- --- --- H7CX-AUSD1 H7CX-AWSD1 ---
None Contact output 12 to 24 VDC --- --- H7CX-AD H7CX-A4D --- --- ---
Transistor output --- --- H7CX-ASD H7CX-A4SD --- H7CX-AWSD H7CX-A4WSD
H7CX-A@@@@@@
1 2 3 4 5 6
Name Models
Flush Mounting Adapter (See note 1.) Y92F-30
Waterproof Packing (See note 1.) Y92S-29
Track Mounting/Front
Connecting Socket 11-pin P2CF-11
11-pin, finger-safe type P2CF-11-E
Back Connecting Socket 11-pin P3GA-11
11-pin, finger-safe type P3GA-11 with Y92A-48G (See note 2.)
Hard Cover Y92A-48
Soft Cover Y92A-48F1
Mounting Track 50 cm (l)
7.3 mm (t) PFP-50N
1 m (l)
7.3 mm (t) PFP-100N
1 m (l)
16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S

6
H7CXH7CX
Specifications
■Ratings
Note: 1. Permissible ripple: 20% (p-p) max.
2. Only when the following modes are selected.
Input mode: command, individual, or quadrature; output mode: K-2, D, or L
Item H7CX-A4@H7CX-A@H7CX-A114@H7CX-A11@
Classification Preset counter
Supported
configurations 1-stage counter, 1-stage counter with total counter (selectable)
Rated supply voltage
(See note 1.) 100 to 240 VAC (50/60 Hz), 12 to 24 VDC 100 to 240 VAC (50/60 Hz)
24 VAC (50/60 Hz)/12 to 24 VDC
Operating voltage
range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method Flush mounting Flush mounting, surface mounting, or DIN track mounting
External connections Screw terminals 11-pin socket
Terminal screw
tightening torque 0.5 N·m max. ---
Display 7-segment, negative transmissive LCD;
PV 11.5-mm-high characters, red
or green (programmable) 9-mm-high characters, red or
green (programmable) 11.5-mm-high characters, red 9-mm-high characters, red
SV 6-mm-high characters, green
Digits 4 digits (
-
999 to 9,999)
SV range: 0 to 9,999 6 digits (
-
99,999 to 999,999)
SV range:
-
99,999 to 999,999
(See note 2.) or 0 to 999,999
4 digits (
-
999 to 9,999)
SV range: 0 to 9,999 6 digits (
-
99,999 to 999,999)
SV range:
-
99,999 to 999,999
(See note 2.) or 0 to 999,999
Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input modes Increment, decrement, command, individual, and quadrature
Input signals CP1, CP2, reset, and total reset
Input method No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 k
W
max. (Leakage current: 5 to 20 mA at 0
W
)
ON residual voltage: 3 V max.
OFF impedance: 100 k
W
min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k
W
)
Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A,
K-2, D, L N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A,
K-2, D, L
One-shot output time 0.01 to 99.99 s
Output type Contact type: SPDT
Transistor type: 1 transistor
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cos
f
=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
NEMA B300 Pilot Duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 HP 5-A resistive load at 240 VAC
External power supply 12 VDC (
10%), 100 mA (except for H7CX-A@D models)
Refer to Precautions for details.
Key protection Yes
Prescaling function Yes (0.001 to 9.999) Yes (0.001 to 99.999) Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Decimal point
adjustment Yes (rightmost 3 digits)
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating:
-
10 to 55
C (
-
10 to 50
C if counters are mounted side by side) (with no icing or condensation)
Storage:
-
25 to 65
C (with no icing or condensation)
Ambient humidity 25% to 85%
Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments Waterproof packing, flush mounting adapter None

7
H7CXH7CX
■Ratings (contd.)
Note: 1. Permissible ripple: 20% (p-p) max.
2. Only when the following modes are selected.
- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H
- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation
Item H7CX-A4W@H7CX-AW@H7CX-AU@
Classification Preset counter Preset counter/tachometer
Supported configurations 1-stage counter, 2-stage counter, 1-
stage counter with total counter, 1-
stage counter with batch counter,
dual counter (selectable)
1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter
with batch counter, dual counter, tachometer (selectable)
Rated supply voltage (See note 1.) 100 to 240 VAC (50/60 Hz),
12 to 24 VDC 100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC,
12 to 24 VDC
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method Flush mounting
External connections Screw terminals
Terminal screw tightening torque 0.5 N·m max.
Display 7-segment, negative transmissive LCD
PV 11.5-mm-high characters, red or
green (programmable) 9-mm-high characters, red or green (programmable)
SV 6-mm-high characters, green
Digits 4 digits (
-
999 to 9,999)
SV range: 0 to 9,999 6 digits (
-
99,999 to 999,999 or 0 to 999,999 when using as Tachometer)
SV range:
-
99,999 to 999,999 (See note 2.) or 0 to 999,999
Input signals CP1, CP2, reset 1, and reset 2
Input method No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 k
W
max. (Leakage current: 5 to 20 mA at 0
W
)
ON residual voltage: 3 V max.
OFF impedance: 100 k
W
min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k
W
)
Counter Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input mode Increment, decrement, command, individual, and quadrature
Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A, K-2, D, L, H
One-shot output time 0.01 to 99.99 s
Tachometer Pulse measurement
method --- Periodic measurement (Sampling period: 200 ms)
Max. counting speed --- 30 Hz or 10 kHz (selectable)
Measuring ranges --- 30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Measuring accuracy ---
0.1% FS
1 digit max. (at 23
5
C)
Output modes --- HI-LO, AREA, HI-HI, LO-LO
Auto-zero time --- 0.1 to 99.9 s
Startup time --- 0.0 to 99.9 s
Average processing --- OFF/2/4/8 times
Output type H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1)
H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors H7CX-AU/-AUD1: SPDT and 1 transistor
H7CX-AUSD1: 2 transistors
(Output allocation possible)
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cos
f
=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
NEMA B300 Pilot Duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 HP 5-A resistive load at 240 VAC
External power supply 12 VDC (
10%) 100 mA (except for H7CX-A@D models)
Refer to Precautions for details.
Key protection Yes
Prescaling function Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating:
-
10 to 55
C (
-
10 to 50
C if counters are mounted side by side) (with no icing or condensation)
Storage:
-
25 to 65
C (with no icing or condensation)
Ambient humidity 25% to 85%
Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments Waterproof packing, flush mounting adapter

8
H7CXH7CX
■Characteristics
Note: 1. To meet UL listing requirements with the H7CX-A11@models, an OMRON P2CF-11-@or P3GA-11 Socket must be mounted
on the H7CX. Otherwise, H7CX-A11@models are considered to meet UL508 recognition requirements.
2. A waterproof packing is necessary to ensure IP66 waterproofing between the H7CX and installation panel.
item H7CX
Insulation resistance 100 M
W
min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and
between non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/
12 to 24 VDC)
1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit
(2,000 VAC for models other than H7CX-@SD/-@SD1)
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand
voltage 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC,
1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
Noise immunity
1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC,
480 V for 12 to 24 VDC
600 V (between input terminals)
Square-wave noise by noise simulator (pulse width: 100 ns/1
m
s, 1-ns rise)
Static immunity Destruction: 15 kV
Malfunction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction: 10 to 55 Hz with 0.35-mm single amplitude each in three directions
Shock resistance Destruction: 294 m/s2each in three directions
Malfunction: 98 m/s2each in three directions
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
Approved safety
standards
(See note 1.)
UL508/Listing, CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II)
Conforms to VDE0106/P100 (finger protection).
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class A
Emission AC mains: EN55011 Group 1 class A
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz
5 MHz) (level 3)
Immunity Conducted
Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Degree of protection Panel surface: IP66 and NEMA Type 4 (indoors) (See note 2.)
Weight Approx. 140 g

9
H7CXH7CX
■Engineering Data (Reference Values)
Reference: A current of 0.15 A max. can be switched at 125 VDC (cos
f
=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both
cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P).
1,000
700
500
300
100
70
50 01 23
No. of operations (
10
3
)
250 VAC (cos
f
=1)
Load current (A)
30 VDC (cos
f
=1)
Electrical Life Expectancy
(Resistive Load)
1,000
700
500
300
100
70
50 012
No. of operations (
10
3
)
250 VAC cos
f
=0.4
Load current (A)
30 VDC (L/R=7 ms)
Electrical Life Expectancy
(Inductive Load)

10
H7CXH7CX
Nomenclature
Reset Operation by Reset Key
1
2
3
4
5
6
9
10
1
2
3
4
5
6
9
10
8
7
11
12
8
7
11
13 14
Indicators Operation Keys
Switches
Reset Indicator (Orange)
Lit when the reset input (1) or reset key
is ON.
Control Output Indicator (Orange)
OUT: One stage
OUT1, OUT2: Two stages
Total Count Indicator
Lit when the total count value is
displayed.
Key Protection Indicator (Orange)
Set Value 1, 2 Stage Indicator
Batch Indicator
Lit when the batch count value is
displayed.
Present Value (Main Display)
Character height: 11.5 mm (6-digit: 9 mm)
Set Value (Sub-display)
Front view of 4-digit model
Front view of 6-digit model
Up Keys: 1 to 4
(6-digit models: 1 to 6)
Reset Key
The operation of the reset function
depends on the configuration selected
as shown in the table below.
Mode Key
Used to switch mode and setting items.
Down Keys: 1 to 4
Key Protect Switch
(Factory setting) OFF ON
DIP Switch
Character height: 6 mm
Configuration Reset operation
1-stage/2-
stage counter Resets the present value and outputs.
Total and pre-
set counter • Resets the present value and outputs.
• When the total count value is displayed, re-
sets the present value, the total count value,
and outputs.
Batch counter • Resets the present value and OUT2.
• When the batch count value is displayed, re-
sets the present value, the batch count val-
ue, and outputs.
Dual counter Resets the CP1 present value, CP2 present
value, dual count value, and outputs.
Tachometer Maintains the measured value and outputs
(hold function).

11
H7CXH7CX
Operation
■Block Diagram
Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.
■I/O Functions
Using as a Counter
Note: In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to
the set value with 1-stage models, and returns to set value 2 with 2-stage models.
Using as a Tachometer
Input circuit Internal control
circuit
Power supply
circuit
(Basic
insulation)
Display circuit
Key switch
circuit
(See note.)
Output circuit
(Basic
insulation)
Inputs CP1, CP2 • In general (except for dual counter mode)
Reads counting signals
Increment, decrement, command, individual, and quadrature inputs accepted.
• When used as a dual counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
Reset or Reset 1 • In general (except for dual counter mode)
Resets present value and outputs (OUT2 when using the batch counter). (See note.)
Counting cannot be performed during reset/reset 1 input.
The reset indicator is lit during reset input.
• When used as a dual counter
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed during reset 1 input.
The reset indicator is lit during reset 1 input.
Total Reset or
Reset 2 • When used as a 1-stage/2-stage counter
Does not operate (Not used).
• When used as a total and preset counter
Resets the total count value.
Hold the total count value at 0 during total reset input.
• When used as a batch counter
Rest the batch count value and batch output (OUT1).
Holds the batch count value at 0 during reset 2 input.
• When used as a dual counter
Resets the CP2 present value.
Counting for CP2 input cannot be performed during reset 2 input.
Outputs OUT1, OUT2 Outputs take place according to designated output mode when corresponding preset is
reached.
Inputs CP1, CP2 Reads counting signals. (CP2 input is not used.)
Reset 1, Reset 2 Holds the measurement value and outputs. (Reset 2 input is not used.)
The reset indicator is lit during hold.
Outputs OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached.

12
H7CXH7CX
Setting Procedure Guide
■Setting for Counter Operation
(1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter)
Note: 1. At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@models) configuration.
2. Set to output 2 time when using as a 2-stage counter or batch counter.
■Setting for Tachometer Operation
Note: At the time of delivery, the H7CX is set to the 2-stage counter (1-stage counter for H7CX-AU@models) configuration.
1
OFF
ON
2345678
When Using Basic Settings Only
• Counting speed (30 Hz, 5 kHz)
• Input mode (UP, DOWN)
• Output mode (N, F, C, K-1)
• One-shot output time (0.5 s, 0.05 s) (See note 2.)
• Reset input signal width (20 ms, 1 ms)
• NPN/PNP input mode (NPN, PNP)
The settings can be performed easily with the DIP switch.
➡For details on the setting methods, refer to page 13.
When Using Settings Other than the Above
All the functions can be set with the operation keys.
➡For details on the setting methods, refer to page 14.
When Using Advanced Functions
Settings for advanced functions other than the basic settings
above can be performed with the operation keys.
➡For details on the setting methods, refer to page 14.
Basic Settings
• Input mode (UP/DOWN A, UP/DOWN B, UP/DOWN C)
• Output mode (R, P, Q, A, K-2, D, L, H)
• One-shot output time (except for 0.5 s and 0.05 s) (See note 2.)
Other Settings • Dual count calculating mode
• Output 1 time (for 2-stage counter)
• Decimal point position
• Prescale value
• Display color
• Output allocation
• Key protect level
Advanced Functions
1
OFF
ON
2345678
When Using Basic Settings Only
• Counting speed (30 Hz, 5 kHz)
• Output mode (HI-LO, AREA, HI-HI, LO-LO)
• Average processing (OFF, 2, 4, 8 times)
• NPN/PNP input mode (NPN, PNP)
The settings can be performed easily with the DIP switch.
➡For details on the setting methods, refer to page 25.
When Using Advanced Functions
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
➡For details on the setting methods, refer to page 26.
Basic Settings
• Decimal point position
• Prescale value
• Auto-zero time
• Startup time
• Display color
• Output allocation
• Key protect level
Advanced Functions

13
H7CX (Counter Function)H7CX (Counter Function)
Operation (Counter Function)
■Settings for Basic Operations
Note: Set to one-shot output 2 time when using as a 2-stage
counter or batch counter.
Easy Confirmation of Switch Settings Using Indicators
The ON/OFF status of the DIP switch pins can be
confirmed using the front display. For details, refer to page 31.
Note: 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled.
2. Changes to DIP switch settings are enabled when the power is turned ON.
3. When setting input modes, output modes, or output times that cannot be set with the DIP switch, all of the settings have to be made using the
operation keys. For details on the setting methods, refer to page 14. When making settings using the operation keys, be sure to set pin 1 of the
DIP switch to OFF.
1
OFF
ON
2345678
Settings for basic functions can be performed with just the DIP switch.
Be sure to set pin 1 to ON.
Note: All of the pins are factory-set to OFF.
Item OFF ON
1 DIP switch settings enable/
disable Disabled Enabled
2 Counting speed 30 Hz 5 kHz
3 Input mode UP (increment) DOWN
(decrement)
4 Output mode Refer to the table on the right.
5
6 One-shot output time
(See note.) 0.5 s 0.05 s
7 Reset input signal width 20 ms 1 ms
8 NPN/PNP input mode NPN PNP
Pin 4 Pin 5 Output mode
OFF OFF N
ON OFF F
OFF ON C
ON ON K-1
Select the configuration using the and keys ( key with 6-digit models).
The H7CX is factory-set to the 1-stage
counter (2-stage counter for H7CX-AW@/-
A4W@models) configuration. To change to
a different configuration, use the procedure
shown on the right. For details, refer to
page 31.
Note: This includes changing to the 2-
stage counter (or 1-stage counter)
configuration.
Switching to Total and Preset Counter, Batch Counter, and Dual Counter Operation (See note.)
Configuration selection mode Run mode
Power ON
(1-stage
counter) (Batch
counter)
(2-stage
counter) (Total and
preset counter) (Dual
counter) (Tachometer)
Note: The configurations that can be selected vary with the model.
Hold down for
1 s min. (See note.)
1
MODE
Note: The key must be pressed before the key.
+
MODE
1
Advanced-Function Settings
After making DIP switch settings for basic operations, advanced functions (see note) can be added using the operation keys.
For details, refer to page 14.
Note: Advanced functions consist of the dual count calculating mode, output 1 time (for 2-stage counter), decimal point position, prescale value, display
color, output allocation, and key protect level.

14
H7CX (Counter Function)H7CX (Counter Function)
■Settings for All Functions
Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@models) configuration. When using as a 2-
stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure given on page 31.
(1ms)(20ms)
(30Hz) (5kHz)
(N)
(0.50s) (99.99s)(0.01s)
(0.50s) (99.99s)(0.01s)
(0.01s) (99.99s)
(F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H)
(DOWN)
(UP/DOWN A) (UP/DOWN B) (UP/DOWN C)
(UP)
(KP-1) (KP-2) (KP-3) (KP-4) (KP-5)
(99.999) [9.999](1.000)(0.001)
(0.50s) (99.99s)(0.01s)
∼∼
Set each setting item using the keys. ( key only for 6-digit models)
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed.
Note 5: Display only when the input mode is UP/DOWN A, B, or
C with 6-digit models (with H7CX-AU@/-AW@models
only for H).
Power ON
Note 4: Displayed for output modes other than K-2, D, L, and H only.
Input mode
Output mode
One-shot
output
time
NPN/PNP
input mode
Display color
Key protect
level
See note 1. See note 2.
Note: 1. If the mode is switched to the function setting mode during operation, operation will con-
tinue.
2. Changes made to settings in functionsetting mode are enabledfor thefirst timewhen the
mode is changed to run mode. Also, when settings are changed, the counter is reset
(present value initialized and output turned OFF) on returning to run mode.
For details on operations in run mode, refer to page 19.
Run modeFunction setting mode
3 s min. 3 s min.
When using as a 2-stage counter:
Dual count
calculating mode
Note: Displayed for output modes
other than K-2, D, L, and H only.
(Addition) (Subtraction)
One-
shot
output
2 time
One-
shot
output
1 time
One-
shot
output
2 time
When using as a
batch counter:
(Outputs held)
Note: Displayed only when the output mode is C, R, K-1, P, Q,
A, or K-2.
See note 7.
(NPN
input) (PNP
input)
Counting
speed
Resetinput
signal
width
Decimal
point
position
Prescale
value
See note 3.
See note 6.
See note 5.
See note 4.
See note.
See note 4.
See note 5.
See note 5.
See note 5.
No decimal
point One digit after
decimal point Two digits after
decimal point Three digits after
decimal point
Note: Displayed for terminal-block models (except H7CX-A11@) only.
(Red) (Green) (Red-green) (Green-red)
Note: Displayed only when the output
mode is C, R, K-1, P, Q, A, or K-2.
If the output time is 0.00,
'.+#
is
displayed.
Note 1: Displayed for output modes
other than D, L, and H.
Note 2: HOLD cannot be set when
the output mode is K-2.
Note: Displayed only when the output
mode is C, R, K-1, P, Q, A, or K-2.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Output
allocation
When using as a dual counter:
Note 3:
Note 6:
See note 7.
Note 7: The displays for 4-digit models are shown inside
parentheses.
Note: Displayed for H7CX-AU@models only.

15
H7CX (Counter Function)H7CX (Counter Function)
■Explanation of Functions
Input Mode (
"-3,
) (Setting possible using DIP switch.)
Set increment mode (UP), decrement mode (DOWN), or one of
the increment/decrement modes (UP/DOWN A, UP/DOWN B, or
UP/DOWN C) as the input mode. Input modes other than UP or
DOWN modes cannot be set using the DIP switch and so use the
operation keys if other modes are required. (For details on the
operation of the input modes, refer to Input Modes and Present
Value on page 18.)
Dual Count Calculating Mode (
" +,
)
When using as a dual counter, select either ADD (addition) or
SUB (subtraction) as the calculation method for the dual count
value.
ADD: Dual count value = CP1 PV + CP2 PV
SUB: Dual count value = CP1 PV
-
CP2 PV
Output Mode (
.43,
) (Setting possible using DIP switch.)
Set the way that control output for the present value is output. The
possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
Output modes other than N, F, C, or K-1 cannot be set using the
DIP switch and so use the operation keys if other modes are
required. The output modes that can be set vary with the model.
(For details on the operation of the output modes, refer to Input/
Output Mode Settings on page 19.)
One-shot Output Time (
.3(,
) (Setting possible using DIP
switch.)
Set the one-shot output time (0.01 to 99.99 s) for control output.
One-shot output can be used only when C, R, K-1, P, Q, A, or K-2
is selected as the output mode. Output times other than 0.5 s or
0.05 s cannot be set with the DIP switch and so use the operation
keys if other settings are required.
One-shot Output 2 Time (
.3,
) (Setting possible using DIP
switch.)
When using as a 2-stage counter or batch counter, set the one-
shot output time (0.01 to 99.99 s) for control output (OUT2). One-
shot output can be used only when C, R, K-1, P, Q, A, or K-2 is
selected as the output mode. Output times other than 0.5 s or
0.05 s cannot be set with the DIP switch and so use the operation
keys if other settings are required.
One-shot Output 1 Time (
.3,
)
When using as a 2-stage counter, set the one-shot output time
(0.01 to 99.99 s) for control output (OUT1). One-shot output can
be used only when D, L, or H is selected as the output mode. If
the output time is set to 0.00,
'.+#
is displayed, and outputs are
held. HOLD cannot be set when the output mode is K-2.
Counting Speed (
"-32
) (Setting possible using DIP switch.)
Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2
inputs together. If contacts are used for input signals, set the
counting speed to 30 Hz. Processing to eliminate chattering is
performed for this setting.
Reset Input Signal Width (
(%+3
) (Setting possible using DIP
switch.)
Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and
total reset/reset 2 inputs together. If contacts are used for input
signals, set the counting speed to 20 ms. Processing to eliminate
chattering is performed for this setting.
Decimal Point Position (
#/
)
Decide the decimal point position for the present value, CP1/CP2
present values, set value (SV1, SV2), total count value, and dual
count set value.
Prescale Value (
/2"+
)
Pulses input to the counter are converted according to the speci-
fied prescale value. (Setting range: 0.001 to 99.999 for 6-digit
models and 0.001 to 9.999 for 4-digit models.)
Example: To display the feed distance for systems that output
25 pulses for a feed length of 0.5 m in the form
@@.@@ m:
1. Set the decimal point position to 2 decimal places.
2. Set the prescale value to 0.02 (0.5
25).
NPN/PNP Input Mode (
(,.#
)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. The same setting is used for all exter-
nal inputs. For details on input connections, refer to Input Connec-
tion on page 36.
Display Color (
".+1
)
Set the color used for the present value.
Note: When using as a 2-stage counter, this is the status of out-
put 2.
Output Allocation (
.323
)
When using H7CX-AU@models as a 2-stage counter, the output
can be flexibly allocated to either stage 1 or 2.
Transistor output can be allocated to SV1 and contact output for
SV2 or vice verce, as in the following table.
H7CX-AU/-AUD1
H7CX-AUSD1
Output OFF (See note.) Output ON (See note.)
1$# Red (fixed)
&1- Green (fixed)
1& Red Green
&1 Green Red
OUT1 OUT2
.%% Transistor (12-13) Contact (3, 4, 5)
.- Contact (3, 4, 5) Transistor (12-13)
OUT1 OUT2
.%% Transistor (12-13) Transistor with diode
(3, 4, 5)
.- Transistor with diode
(3, 4, 5) Transistor (12-13)
0.5m
Encoder
25 pulses

16
H7CX (Counter Function)H7CX (Counter Function)
Key Protect Level (
*7/3
)
Set the key protect level.
When the key-protect switch in set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specify-
ing the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status
of the key-protect switch after the H7CX is mounted to the panel.
Note: Changing mode to configuration selection mode ( + 1 s min.) or function setting mode ( 3 s min.).
Level Meaning Details
Changing mode
(See note.) Switching display
during operation Reset key Up/down key (Up key
for 6-digit models)
KP-1 (default setting) No Yes Yes Yes
KP-2 No Yes No Yes
KP-3 No Yes Yes No
KP-4 No Yes No No
KP-5 No No No No
ON
OFF
Note: Factory-set to OFF
Key protect indicator
(See note)
MODE
1
MODE

17
H7CX (Counter Function)H7CX (Counter Function)
■Operation in Run Mode
Note: ★ indicates the displays at power-ON for the respective configurations.
Set values for each digit as required using the and keys. ( key only for 6-digit models.)
1-stage Counter
2-stage Counter
Total and Preset Counter
Batch Counter
Dual Counter
CP2 present value
CP1 present value
Dual count set value
Dual count value
Batch count set value
Present value
Batch count value
Set value
Present value
Total count value
Set value
Present value
Present value
Set value 2
Set value 1
Present value
Set value
Present Value
Shows the present count value.
Set Value (Set Value 1, Set Value 2)
Set the set value. When the present
value reaches the set value, signals
are output according to the specified
output mode.
Present Value/Set Value
Same as 1-stage counter.
Total Count Value
Shows the present total count value.
Present Value/Set Value
Same as 1-stage counter.
Batch Count Value
Shows the number of times the count has
been completed for the present value.
Batch Count Set Value
Set the batch count set value. When the
batch count value reaches the batch count
set value, batch output (OUT1) turns ON.
Dual Count Value
Shows the sum of the CP1 present value and CP2 present value when the
dual count calculating mode is ADD and shows the value obtained by
subtracting the CP2 present value from the CP1 present value when the dual
count calculating mode is SUB.
Dual Count Set Value
Set the dual count set value. When the dual count value reaches the dual
count set value, signals are output according to the specified output mode.
CP1/CP2 Present Value
Show the present count values for CP1 and CP2 present values respectively.

18
H7CX (Counter Function)H7CX (Counter Function)
■Input Modes and Present Value
Note: 1. If the configuration selection is set to dual counter, re-
gardless of the input mode setting, CP1 and CP2 input
will operate in the same way as the count input (CP1)
of UP (increment) mode.
2.
must be greater than the minimum signal width and
must be at least 1/2 the minimum signal width. If
they are less, a count error of
1 may occur.
Minimum signal width:16.7 ms (when maximum
counting speed = 30 Hz)
100
m
s (when maximum
counting speed = 5 kHz)
3. The meaning of the H and L symbols in the tables is ex-
plained below.
UP (Increment) Mode DOWN (Decrement) Mode
0
CP1 H
L
CP2 H
L
0
1
2
4
3
5
A A
Prohibit
Present
value
CP1: Count input; CP2: Prohibit (gate) input
Note: Input CP2 while CP1 is "L."
must be greater
than the minimum signal width. (See note 2.)
n
CP1 H
L
CP2 H
L
0
n−1
n−2
n−4
n−3
n−5
A A
Prohibit
Present
value
Note: Input CP2 while CP1 is "L."
must be greater than
the minimum signal width. (See note 2.)
CP1: Count input; CP2: Prohibit (gate) input
0
CP1 H
L
CP2 H
L
0
1
2
4
3
5
A A
Prohibit
Present
value
Note: Input CP1 while CP2 is "H."
must be greater
than the minimum signal width. (See note 2.)
CP1: Prohibit (gate) input; CP2: Count input
n
CP1 H
L
CP2 H
L
0
n−1
n−2
n−4
n−3
n−5
A A
Prohibit
Present
value
Note: Input CP1 while CP2 is "H."
must be greater
than the minimum signal width. (See note 2.)
CP1: Prohibit (gate) input; CP2: Present value
UP/DOWN A
Command Input Mode
UP/DOWN B
Individual Input Mode
UP/DOWN C
Quadrature Input Mode
0
CP1 H
L
CP2 H
L
0
1
22
2
1
33
A A
Present
value
must be greater than the minimum signal width. (See note 2.)
0
CP1 H
L
CP2 H
L
0
1
22
2
11
33
Present
value
0
CP1 H
L
CP2 H
L
0
1
22
2
1
33
B B B B
Present
value
must be at least 1/2 the minimum signal width. (See note 2.)
Input method No-voltageinput
(NPN input) Voltage input
(PNP input)
Symbol
HShort-circuit 4.5 to 30 VDC
LOpen 0 to 2 VDC

19
H7CX (Counter Function)H7CX (Counter Function)
■Input/Output Mode Settings
Operation for 1-stage models is the same as that for OUT2.
When using a 2-stage model as a 1-stage counter, total and pre-
set counter, or dual counter, OUT1 and OUT2 turn ON and OFF
simultaneously.
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
2. When the present value reaches 999999, it returns to 0.
One-shot output from OUT1
Self-holding output Self-holding output One-shot output from OUT2
(The one-shot output time
can be set in the range 0.01
to 99.99 s.)
Input mode Operation after
count completion
UP DOWN UP/DOWN A, B, C
Output
mode
setting
NThe outputs and
present value display
are held until reset/re-
set 1 is input.
FThe present value dis-
play continues to in-
crease/decrease. The
outputs are held until
reset/reset 1 is input.
CAs soon as the count
reaches SV, the
present value display
returns to the reset
start status. The
present value display
does not show the
present value upon
count-up.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turnsOFF after
the OUT2 one-shot
outputtime.TheOUT1
one-shot output time
is independent of
OUT2.
RThe present value dis-
play returns to the re-
set start status after
the one-shot output
time.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turnsOFF after
the OUT2 one-shot
outputtime.TheOUT1
one-shot output time
is independent of
OUT2.
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2

20
H7CX (Counter Function)H7CX (Counter Function)
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
2. When the present value reaches 999999, it returns to 0.
Input mode Operation after
count
completion
UP DOWN UP/DOWN A, B, C
Output
mode
setting
K-1 The present val-
ue display contin-
ues to increase/
decrease.
OUT1 self-hold-
ing output turns
OFF after the
OUT2 one-shot
output time.The
OUT1 one-shot
output time is in-
dependent of
OUT2.
PThe present val-
ue display does
not change dur-
ing the one-shot
output time peri-
od, but theactual
count returns to
the reset start
status.
The outputs re-
turn to the one-
shot start state
and repeat one-
shot operation.
OUT1 self-hold-
ing output turns
OFF after the
OUT2 one-shot
output time. The
OUT1 one-shot
output time is in-
dependent of
OUT2.
QThe present val-
ue continues to
increase/de-
crease for the
one-shot output
time, but returns
to the reset start
status after the
one-shot output
time has
elapsed.
The outputs re-
peat one-shot
operation.
OUT1 self-hold-
ing output turns
OFF after the
OUT2 one-shot
output time. The
OUT1 one-shot
output time is in-
dependent of
OUT2.
AThe present val-
ue display and
OUT1 self-hold-
ing output is held
until reset/reset1
is input. OUT1
and OUT2 are in-
dependent.
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
999999
0
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2

21
H7CX (Counter Function)H7CX (Counter Function)
Note: 1. Counting cannot be performed during reset/reset 1 input.
2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
3. If the count is reached while one-shot output is ON, the one-shot output is newly generated.
Input mode Operation after count
completion
UP/DOWN A, B, C
Output
mode
setting
K-2 The display continues to increase/
decrease until the overflow or un-
derflow value is reached. One-shot
output only.
DThe display continues to increase/
decrease until the overflow or un-
derflow value is reached. The out-
puts are ON while the count is
equal.
LThe display continues to increase/
decrease until the overflow or un-
derflow value is reached.
OUT1 is held while the present val-
ue is less than or equal to set value
1. OUT2 is held while the present
value is greater than or equal to set
value 2.
HThe display continues to increase/
decrease until the overflow or un-
derflow value is reached.
OUT1 is held while the present val-
ue is greater than or equal to set
value 1. OUT2 is held while the
present value is greater than or
equal to set value 2.
Note:
H mode is available for 2-stage
models only.
Instantaneous
(equals) output
Self-holding
output One-shot
output
(The one-shot output time
can be set in the range0.01
to 99.99 s.)
0
999999
−99999
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
0
999999
−99999
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
0
999999
−99999
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
0
999999
−99999
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2

22
H7CX (Counter Function)H7CX (Counter Function)
Total and Preset Counter Operation
The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value.
Batch Counter Operation
The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed.
Note: 1. The batch count value is held at 0 during batch counter reset input.
2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
3. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models).
4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output
will turn ON.
6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the
batch count value.
• The total counter continues to count the to-
tal accumulated value when the present
value is reset using reset/reset 1 input (re-
set key).
• The total count value is reset when the to-
tal reset/reset 2 input is turned ON. If the
reset key is pressed while the total count
value is displayed, the total count value is
reset. The present value is also reset at
this time.
• The counting range of the total counteris
-
99,999 to 999,999 (
-
999 to 9,999). The to-
tal count value returns to 0 when it reaches
the full scale limit.
0
0
999999
Reset/reset 1
Total reset/reset 2
Present value
Total count value
Note: The full scale (FS) for H7CX 4-digit models is 9999.
• The batch counter continues after count
completion.
• Batch output is held until batch counter re-
set is input.
• When the batch counter reset input is
turned ON, the batch count value is reset,
and batch output turns OFF.
• If the reset key is pressed while the batch
count value is displayed, the batch count
value is reset and batch output turns OFF.
The present value is also reset at this time.
0
0
Reset 1
Reset 2 (batch
counter reset)
Set value
Present value
OUT2
Batch count set value
Batch count value
OUT1 (batch output)Note: The above is for when the output mode is C.

23
H7CX (Counter Function)H7CX (Counter Function)
Dual Counter Operation
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set
value for which output turns ON when the set value matches the added or subtracted result.
OUT1 and OUT2 turn ON and OFF simultaneously.
Note: 1. Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on
a CP1 present value of 0.
2. Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on
a CP2 present value of 0.
3. The counting range for the dual count value is
-
99,999 to 999,999 (
-
999 to 9,999 for 4-digit models). The counting ranges for
the CP1 present value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models). If a present value exceeds 999,999
(9,999 for 4-digit models), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting will stop.
• The operation after count
completion for the dual
counter value is determined
by the output mode.
• The CP1 present value is re-
set when reset 1 input is
turned ON and the CP2
present value is reset when
reset 2 input is turned ON.
• If the reset key is pressed
while the dual count value,
CP1 present value, or CP2
present value is displayed, all
of the present values are re-
set and outputs turn OFF. At
this time, counting is not pos-
sible for CP1 or CP2 inputs.
0
0
0
0
0
0
Dual Count Calculating Mode = ADD
Dual count value = CP1 PV + CP2 PV Dual Count Calculating Mode = SUB
Dual count value = CP1 PV
-
CP2 PV
Reset 1
(CP1 reset)
Reset 2
(CP2 reset)
Dual count set value
Dual count value
CP1 present value
CP2 present value
OUT1, 2
Note: The above is for when the output mode is N. Note: The above is for when the output mode is K-2.
Reset 1
(CP1 reset)
Reset 2
(CP2 reset)
Dual count value
Dual count set value
CP1 present value
CP2 present value
OUT1, 2
This manual suits for next models
27
Table of contents
Other Omron Cash Counter manuals

Omron
Omron H7CX-R11D1 User manual

Omron
Omron H7CX-Ax-N Series User manual

Omron
Omron GO SMART HJ-203 User manual

Omron
Omron H8CA-S Series User manual

Omron
Omron HJ-321-E User manual

Omron
Omron SYSMAC CS Series User manual

Omron
Omron H7BX - User manual

Omron
Omron HJ-325-EW User manual

Omron
Omron H7GP - User manual

Omron
Omron CS1 - User manual

Omron
Omron H7ET Series User manual

Omron
Omron H7CR-A Series User manual

Omron
Omron H7CN User manual

Omron
Omron H7CX - User manual

Omron
Omron H7E-P Series User manual

Omron
Omron H8BM Series User manual

Omron
Omron H8BM-R Series User manual

Omron
Omron C200H-CT021 User manual

Omron
Omron H7BR Series User manual

Omron
Omron H7BX - User manual