H8GN H8GN
12
Setting Specifications after Turning ON Power
Outline of Operation Procedure
Key Operation
In
the following descriptions,
all the parameters are introduced in the display sequence. Some parameters may not be displayed depending on
the
protection settings and operating conditions.
Power ON
Operation level
Adjustment level
Protect level
Operation stops
Communications
setting level
1
s. min.
Initial
setting level
Advanced function
setting level
Operation in progress
Operation stopped
Not displayed depending on model and settings.
Not displayed depending on model and settings.
Level change
3
s min.
less than 1 s.
3 s. min. (default value)
Keys 1 s. min.
less than 1 s.
1 s. min.
Password input set value “–169”
+
+
Key Key
Key
Keys
Key
Key
Note: Of
these levels, the initial setting level, communications setting level, and advanced function setting level can
be used only when op
-
eration has stopped. Control output is stopped when these three levels are selected. When switched back to the operation level from
one
of these levels, operation will start.
Description of Each Level
Operation Level
•This level is displayed when you turn the power ON. You can
move to the protect level, initial setting level, and adjustment
level
from this level.
•Normally
, select this level during operation.
•During operation, the present value, set value, totalizing count
value, and setting number of SV-bank can be monitored using
the
Key.
Adjustment Level
•To select this level, press the Key once for less than one
second.
•This
level is for entering
set value (SV 0 to 3) for operation. This
level contains parameters for communications writing enable/
disable,
set value of SV
-bank, and cycle time (timer Z mode).
•You
can move to the top parameter of the operation level, protect
level,
or initial setting level from here.
Initial Setting Level
•To
select this level, press the
Key for at least three seconds
in
the operation level or adjustment level.
•This level is for selecting the function, input mode, time range,
timer mode, output mode, output time, counting speed, input
signal width, decimal point position, prescale value, and
rising/falling
edge for input signal.
•You can move to the advanced function setting level or
communications setting level from this initial setting level. To
return
to the operation level, press the
Key for at least
one
second.
T
o move to the communications setting level, press the
key once for less than one second.
Protect Level
•To select this level, simultaneously press the and
Keys for at least three seconds (default value). This level is to
prevent unwanted or accidental modification of parameters.
Protected
levels will not
be displayed, and so the parameters in
that
level cannot be modified.
Communications Setting Level
•To select this level, press the Key once for less than one
second in the initial setting level. When the communications
function
is used, set the communications conditions
in this level.
Communicating with a personal computer (host computer)
allows
set values to be read and written.
Advanced Function Setting Level
•To
select this level, you must change the initial settings/commu
-
nications protection setting in the protect level to “0” and then
enter
the password (“-169”) in the initial setting level.
•This level is for initializing settings, enabling SV-bank and
totalizing counter use, setting display auto-return time, and
move-
to-protect-level time.
•Y
ou can move to the initial setting level from this level.