Present value
Set value
P2CF-08(-E)
Front-connecting Socket
(order separately)
*1: After reaching the last set value, the UKey will return to the first set value.
Function setting mode
CAUTION
Precautions for Safe Use
H7CZ-L8@
Flush Mounting
1. The thickness of a mounting
panel shouldbe 1 to 5 mm.
2. It is possible to mount Timers
side-by-side. (But only towards
the non-hook side.)
A=(48n−2.5) +1
−0
n Units mounted
side-by-side
3. If the products are mounted side
by side, water resistance will be
lost.
Nomenclature
Ratings (Specifications)
Precautions for Correct Use
48
H7CZ
-L8@
92.3* 90
Displays and Settings in Run Mode
-100 to 240 VAC, 50/60 Hz
(H7CZ-L8)
- 12 to 24 VDC/24 VAC, 50/60 Hz
(H7CZ-L8D1)
85% to 110% of rated supply voltage
(12 to 24 VDC: 90% to 110%)
Approx. 9.4 VA at 100 to 240 VAC,
Approx. 7.2 VA/4.7 W at 24 VAC/12
to 24 VDC
−10 to 55°C (−10 to 50°C if Counters
are mounted side by side)
(with no icing or condensation)
−25 to 70°C (with no icing or
condensation)
25% to 85%
2,000 m max.
T2A, 250VAC,time-lag,low-breaking
capacity
Approx. 100 g (main unit only)
Over-voltage category II, pollution
degree 2. (IEC 61010-1)
Power supply voltage
Allowable voltage
fluctuation range
Power consumption
Operating temperature
range
Storage temperature
range
Operating humidity
range
Altitude
Recommended fuse
Weight
Installation
environment
Input method
No-voltage input
Control output
Contact Output
Electrical life of relay
Mechanical life of
relay
External power supply
Degreenof protection
ON impedance: 1 kΩmax. (Leakage
current: 12 mA when 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩmin.
250 VAC, 3 A (resistive load)
30 VDC, 3 A (resistive load)
100,000 operations (at an ambient
temperature of 23°C)
10,000,000 operations (at an ambient
temperature of 23°C)
12 VDC, 100 mA
IEC IP66, UL508 Type 4X*
Operating Procedures
Parameters are set with the operation keys on the front panel.
●Change from RUN Mode to Function Setting Mode.
Power ON Function
setting mode
Run mode
3 s min.
3 s min.
MODE
MODE
●Set the parameters using the UKey.
The characters displayed in reverse video are the default settings.
The following displays will appear if an error occurs.
Main
display
-----
*3
e1
e2
e2
e3 *5
Sub-
display
No
change
Not lit
Not lit
sum
No
change
Description
Present value
underflow *2
CPU error
Memory error
(RAM)
Memory error
(EEPROM) *1
Output Counter
Overflow
Output
status
No
change
OFF
OFF
OFF
No
change
Correction
method
Either press the
Reset Key or
turn ON reset input.
Turn ON the
power again.
Reset Key
Turn ON the
power again.
Reset Key
Reset Key *4
Set value
after reset
No
change
No
change
No
change
Factory
setting.
No
change
*1. This includes times when the life of the EEPROM has expired.
*2. This occurs if the present value falls below –99999.
*3. Display flashes.(1-second cycles)
*4. The total ON count will not be cleared by using the Reset Key.
*5. The normal display and e3 will appear alternately.
When the Reset Key is pressed, e3 will not be displayed even if the
alarm set value is exceeded. (Monitoring is possible, however,
because the Counter will continue without the output ON count being
cleared.)
Display
cntm
outm
otim
cnts
iflt
dp
pscl
sl-h
kypt
on-a
on-c
Parameter name
Input mode
Output mode
Output time
Counting speed
Reset input signal width
Decimal point position
Prescale value
Set value upper limit
Key protect level
Output ON count
alarm set value
Output ON count
monitor value
Displayed only when the output mode is
c,r,k-1,p,q, or a. Unit: second
---
---
---
---
---
---
×1,000
The monitor value is only displayed.
It cannot be set. ×1,000
Set value
up,down
n,f,c,r,k-1,p,q,aK*1
0.01 to 0.50 to 99.99
30hz,5khzK*1
20ms,1msK*1
------,-----.-,
----.--,---.--- *1
0.001 to 1.000 to 99.999
1to 999999
kp-1,kp-2,kp-3,kp-4,
kp-5,kp-6,kp-7K*1
0to 9999
---
H7CZ
Digital Counter
©All Rights Reserved
OMRON Corporation
INSTRUCTION MANUAL
1148606-6A
EN
Thank you for purchasing the OMRON Product.
To ensure the safe application of the Product, read this
manual carefully before using the Product and always keep
it close at hand when the Product is in use.
Suitability for Use
OMRON shall not be responsible for conformity with any
standards, codes, or regulations that apply to the combination
of the products in the customer's application or use of the
product.
Take all necessary steps to determine the suitability of the
product for the systems, machines, and equipment with which
it will be used. Know and observe all prohibitions of use
applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION
INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of
Liability.
Indicates a potentially hazardous situation which, if
not avoided, is likely to result in minor or moderate
injury or in property damage.
Keys to Warning Symbols
SAFETY PRECAUTIONS
CAUTION
Mounting and Panel-cutout Dimensions Diagram
Mounting Dimenions
(Unit: mm)
Front panel dimensions are
the same for all models.
*These dimensions vary with
the type of DIN track
(reference value).
Surface Mounting
Standard panel cutout is shown in
the following diagram (conforms
to DIN 43700). A space of 15 mm
or greater (a panel cut-out
distance of 60 mm or greater) is
rec-ommended towards the
Adapter's hookside to enable
easier mounting work.
@45 +0.6
−0
60 or greater
15 or greater
• Panel-cutout Dimensions Diagram
(Unit: mm)
• Digital Counter
• Instruction manual (this document)
Package Contents
•
•
*Individual mounting: Degree of protection on the front
panel of the Counter conforms to UL 508 Type 4X when all
of the following conditions are satisfied:
The Y92S-29 waterproof packing and Y92F-30 mounting
adapter are used with the Counter. Use only these parts
for replacement.
The Counter is mounted on the flat surface of an
enclosure that is rated and marked "Type 4X for Indoor
Use Only."
Display Section
1. Key Protect Indicator
2. Control Output Indicator
3. Reset Indicator
(Lit when the reset input or
Reset Key is ON.)
4. Present Value (Main
Display)
(Character height: 10 mm)
5. Set Value Display
(Sub-display)
(Character height: 6 mm)
Operation Key
Key-protect Switch Settings
OFF(disable)
ON(enable)
When the key-protect switch
is ON, individual key
operations can be disabled
to prevent setting errors
according to the key protect
levels (KP-1 to KP-7)
shown in the following table.
* Key protect levels are set in
function setting mode.
Key protect indicator
(Factory setting)
* Changing mode to function setting mode.
Level
KP-1
(default setting)
KP-2
KP-3
KP-4
KP-5
KP-6
KP-7
*Mode
change
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Display switch
in the run mode
Valid
Valid
Valid
Valid
Invalid
Invalid
Invalid
Reset
Key
Valid
Invalid
Valid
Invalid
Invalid
Valid
Invalid
Up Key
Valid
Valid
Invalid
Invalid
Invalid
Valid
Valid
Self-diagnostic Functions
For details, refer to the latest datasheet (Cat. No. M079).
1) H7CZ models with a 12 to 24-VDC power supply use a transformer-
free power supply method in which the power supply terminals are not
isolated from the signal input terminals. If a non-isolating DC power
supply is used, unwanted current paths may occasionally burn or
destroy internal components depending on the wiring. Always check
the wiring sufficiently before use.
2) An inrush current of approx. 10 A will flow for a short time when the
power supply is turned ON. If the capacity of the power supply is not
sufficient, the Counter may not start. Be sure to use a power supply
with sufficient capacity.
3) Maintain voltage fluctuations in the power supply within the specified
operating voltage range.
4) To allow for the startup time of peripheral devices (e.g., sensors), start
Counter timing operation 200 ms to 290 ms after turning ON the
power. The input signal will not be accepted before 200 to 290 ms has
elapsed.
5) The input signal will not be accepted after 5 to 1005 ms has elapsed
from when the power supply is turned OFF.
6) Inrush current generated by turning ON or OFF the power supply may
deteriorate contacts on the power supply circuit. Turn ON or OFF to a
device with the rated current of more than 10 A.
7) The capacity of the external power supply is
100 mA at 12 V. When using a 24 VAC/12 to
24 VDC power supply, reduce the load with the
power supply voltage, as shown in the diagram
(DC power supplies only) on the right.
8) If the prescale value setting is incorrect, a
counting error will occur. Check that the
settings are correct before using this function.
9) Make sure that all settings are appropriate for the application.
Unexpected operation resulting in property damage or accidents may
occur if the settings are not appropriate.
10) Do not leave the Counter for long periods at a high temperature with
output current in the ON state. Doing so may result in the premature
deterioration of internal components (e.g., electrolytic capacitors).
11) EEPROM is used as memory when the power is interrupted. The write
life of the EEPROM is 100,000 writes. The EEPROM is written when
the power is turned OFF or when switching from function setting mode
to run mode.
12) Dispose of the product according to local ordinances as they apply.
Do not allow pieces of metal, wire clippings, or fine metallic
shavings or fillings from installation to enter the product.
Doing so may occasionally result in electric shock, fire, or
malfunction.
Minor injury due to explosion may occasionally occur. Do not
use the Counter where subject to flammable or explosive
gas.
Fire may occasionally occur. Tighten the terminal screws to
the rated torque.
P2CF Socket terminals: 4.4 lb-in (0.5 N⋅m)
Minor injury due to electric shock may occasionally occur. Do
not touch any of the terminals while power is being supplied.
Be sure to mount the terminal cover after wiring.
The life expectancy of the output relay varies considerably
according to its usage. Use the output relay within its rated
load and electrical life expectancy. If the output relay is used
beyond its life expectancy, its contacts may become fused or
there may be a risk of fire. Also, be sure that the load current
does not exceed the rated load current and when using a
heater, be sure to use a thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may occasionally
occur. Do not disassemble, modify, or repair the Counter or
touch internal components.
1) When mounting the Counter to a panel, tighten the two mounting screws
alternately, a little at a time, so as to keep them at an equal tightness. If the
panel screws are tightened unequally, water may enter the panel.
2) Store the Counter at the specified temperature. If the Counter has been stored
at a temperature of less than −10°C, allow the Counter to stand at room
temperature for at least 3 hours before use.
3) Mounting the Counter side-by-side may reduce the life expectancies of internal
components.
4) Use the Counter within the specified ranges for the ambient operating
temperature and humidity.
5) Do not use in the following locations:
•Locations subject to sudden or extreme changes in temperature.
•Locations where high humidity may result in condensation.
•Locations with excessive vibration or shock.
•Locations subject to water.
•Locations subject to oil.
6) Do not use the Counter outside of the rated ranges for vibration, shock, water
exposure, and oil exposure.
7) Do not use this Counter in dusty environments, in locations where corrosive gasses
are present, or in locations subject to direct sunlight.
8) Install the Counter well away from any sources of static electricity, such as pipes
transporting molding materials, powders, or liquids.
9) Internal elements may be destroyed if a voltage outside the rated voltage range
is applied.
10) Separate the Counter from sources of noise, such as devices with input signals
from power lines carrying noise, and wiring for I/O signals.
11) Do not connect more than two crimp terminals to the same terminal.
12) Up to two wires of the same size and type can be inserted into a single terminals.
13) Use the specified wires for wiring. Applicable Wires: AWG 18 to AWG 22, solid
or twisted, copper
14) Install a switch or circuit breaker that allows the operator to immediately turn
OFF the power, and label it to clearly indicate its function.
15) Approximately 14 V is output from the input terminals. Use a sensor that
contains a diode.
16) Use a switch, relay, or other contact so that the rated power supply voltage will
be reached within 0.1 seconds. If the power supply voltage is not reached
quickly enough, the Counter may malfunction or outputs may be unstable.
17) Use a switch, relay, or other contact to turn the power supply OFF
instantaneously. Outputs may malfunction and memory errors may occur if the
power supply voltage is decreased gradually.
18) When changing the set value during operation, because the H7CZ uses a
constant read-in system, output will turn ON if the set value is equal to the
present value.
19) If the set value and present value are both 0, the output will turn ON for the
default setting. The output will turn OFF during a reset operation.
20) Do not use organic solvents (such as paint thinners or benzine), strong alkali, or
strong acids. They will damage the external finish.
21) Confirm that indications are working normally, including the LCD. The indicator
LCD and resin parts may deteriorate more quickly depending on the application
environment, preventing normal indications. Periodic inspection and
replacement are required.
22) The waterproof packing may deteriorate, shrink, or harden depending on the
application environment. Periodic inspection and replacement are required.
•When conforming to EMC standards, refer to the information
provided in this Instruction Manual for cable selection and other
conditions.
•This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take
adequate measures to reduce interference.
•Basic insulation is provided between power supply and input
terminals, between power supply and output terminals, and
between input and output terminals. (No insulation is provided
between the power supply and input terminals for the
H7CZ-L8D1.)
•Basic insulation is provided between power supply and output
terminals, and between input and output terminals. When double
insulation or reinforced insulation is required, apply double
insulation or reinforced insulation as defined in IEC 60664 that is
suitable for the maximum operating voltage with clearances or
solid insulation.
•Connect the input and output terminals to devices that do not have
any exposed charged parts.
Conformance to EN/IEC Standards
---
Comments
---
Track Mounting/
Front Connecting Socket
Flush Mounting Adapter
Waterproof Packing
8-pin
8-pin, finger-safe type
---
---
P2CF-08
P2CF-08-E
Y92F-30
Y92S-29
Precautions for Compliance with UL Standards and CSA Standards
Notice to Users of the H7CZ in the USA and Canada
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp, The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC (U.S.A.)
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD. (SINGAPORE)
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
•Accessories (Order Separately)
Note: Refer to the datasheet (Cat. No. M079) for detailed parameter settings.
Wire properly after checking the specifications of the power supply voltage.
Terminal Arrangement
6. Mode Key
(Changes modes and
setting items)
7. Reset Key
8. Up Keys to
16
OV
Count
Internal circuit
Contact Output
Reset
1234
2345
SET
(+)(−)
Input Connections
No-voltage Inputs (NPN Inputs)
Open Collector Voltage Output Contact Input
Note: Operate with transistor ON Note: Operate with transistor ON Note: Operate with relay ON
0 V
Reset
Count
PLC or
sensor
Sensor
0 V
Reset
Count
0 V
Reset
Count
6
7
5
4
8
1st digit6th digit
1
2
3
•Installation in a Panel
H7CZ is normally installed on a flat surface in an operation
panel. Use a Type 1 Enclosure for the operation panel.
•Use the isolated source for Inputs.
•Environment
Surrounding Air Temperature: −10 to 40°C
Please use the following installation information instead of the
general information in the instruction manuals in order to use the
product under certified conditions of UL and CSA when the product
is installed in the USA or Canada. These conditions are required
by NFPA 70, National Electrical Code in the USA and the
Canadian Electrical Code, Part I in Canada and may vary from
information given in the product manuals or safety precautions.
0
20
10.8 15
100
Load
current
(mA)
Power supply voltage (VDC)
(51)
Panel
Y92S-29
(order
separately)
Waterproof
Packing
Y92F-30
(order
separately)
Flush
Mounting
Adapter
P3G-08
(order
separately)
Back-
connecting
Socket
84.87.5