THERMO-HUNTER
BUILT-IN2
BS-02T and BS-LD
are Class 2 laser
products.
LASER DIODE POWER MAX1.0mW
WAVE LENGTH670nm
CLASS2 LASER PRODUCT
CAUTION
DO NOT STARE INTO BEAM
Non-Contact Thermometer
Separate Sensor
BS Series
SPECIFICATIONS
Sensor head
Model BS-30T BS-05T BS-02T
Field of view ø30/500mm ø5/100mm ø2/50mm
Optics Silicon lens
Sensing element/Wavelength Thermopile/8 to 14 m
Sighting method N/A (Use BS-LD for sighting) Coaxial laser marker
(Class 2)
Ambient temperature 0 to 65˚C 0 to 50˚C
(0 to 150˚C: with optional cooling jacket)
Environmental humidity 35 to 85%RH (without dew condensation)
Storage temperature –20 to 70˚C –20 to 60˚C
Vibration resistance 3G (20 — 50Hz, in accordance with JIS C0911)
Water resistance IP67
Weight 300g 400g
Optional accessories Refer to the Optional Accessory Table of the previous page
Amplifier
Model BS-V BS-A
Measuring range 0 to 500˚C
Display range –20 to 520˚C
Response time 500msec./90%
Accuracy ( 1.0)
1% of reading value or
2˚C whichever is greater
Repeatability
1˚C of reading value
Display resolution 1˚C
Analog output 1mV/˚C 4 — 20mA
Output resolution 0.2˚C
Emissivity ratio ( ) adjustment 0.10 to 1.20 (0.01/1 step)
Delay setting 1 (0.5sec) to 200 (approx. 10sec) variable
Power supply/Current consumption
DC12 — 24V
10%/Max 100mA
Ambient temperature 0 to 50˚C
Environmental humidity 35 to 85%RH (without dew condensation)
Storage temperature –20 to 60˚C
Vibration resistance 3G(20 — 50Hz,in accordance with JISC0911)
Water resistance IP65
Weight 320g
Standard accessories Fixture x 1, M4 screw x 2
* A sensor and an amplifier form one complete set.
They do not function individually.
* Specifications may change without prior notice.
DIMENSIONS
BS-WP1
(for BS-30/05T)
Safety Guidelines
Do not look into the laser or direct it toward the eyes. Even the
reflection is harmful. Laser may cause eye injury or damage
your health.
AVOID MEASURING SHINY SURFACES.
Shiny surfaces reflect radiation from surrounding objects. Although the emissivity ratio can be adjusted
to compensate for this problem, accurate measurement is difficult.
USE THE CORRECT VOLTAGE.
Applying voltages other than 12-24VDC may cause short-circuit, damages, fire or injury. In such cases,
turn the power off immediately.
DO NOT LET THE THERMOMETER TOUCH THE OBJECTS THAT IS BEING MEASURED.
The unit is a non-contact thermometer. Touching or getting too close to the objects with high
temperatures may cause irreparable damage or incorrect measurement.
DO NOT TOUCH THE LENS.
Do not touch the lens with anything hard or things with sharp points, which may dameage the lens. A
damaged lens causes incorrect measurement.
KEEP THE THERMOMETER AWAY FROM CHARGED OBJECTS.
This may cause irreparable damage or incorrect measurement.
No. 74040-02-09785-0009
Environmental Warnings
KEEP THE THERMOMETER AWAY FROM DIRECT SUNLIGHT, DUST, HIGH TEMPERATURES
AND HIGH HUMIDITY WHILE IN USE AND STORAGE.
This may cause irreparable damage or incorrect measurement.
DO NOT EXPOSE THE THERMOMETER TO SUDDEN TEMPERATURE CHANGES.
Sudden temperature change of the environment may cause incorrect measurement. In such cases,
wait until the thermometer reaches steady temperature before taking measurement.
KEEP THE THERMOMETER AWAY FROM STRONG ELECTROMAGNETIC SOURCES,
CORROSIVE OR EXPLOSIVE GASES.
This may cause irreparable damage or incorrect measurement.
Usage Warnings
CAUTION
WARNING
This product is not a clinical thermometer; therefore,
it cannot be used for medical purposes.
Products mentioned in this catalogue are equipped with Class 2 laser.
In case of re-export to foreign countries, please confirm the relevant requlation for laser products
in the destination country.
BS-A/BS-V Amplifier Fixture
BS-30T/BS-05T
BS-02T
NB-SH30A
(for BS-30/05T)
•Sensor Mounting Bracket (option)
•Amplifier
•Sensor Head •Air/Water Cooling Jacket (option)
NB-SH40A
(for BS-02T)
Connector
Laser hole
Ring Cover
Model ID
2m Cable
W1/4 Tap
Screw holes
M4 8mm depth
Connector cable
Connector cableCaution label
Cable length
Cable length
Mounting fixture
Air feeder (PF1/8)
Water inlet (PF1/8)
Water outlet (PF1/8)
[Unit: mm]
30
124 2000
50
12
45
68
42.5
92
40
11
6
6
52
2-R6
31
31
2
40
18
150
3.2
6014
12.5
48
45
4270
32
2- 9
30
64
2- 9
84
84
42
60
2
28
42
70
2- 11
90
2- 11
114
114
60
96
36
12.5
15
12
45
104 2000
50
25
345
UKA S
QUALITY
MANAGEMENT
001
16
40
2-R3
2- 6
P.O.Box 24009, 2490 AA The Hague, The Netherlands
TEL +31 (0)70 4194100 FAX +31 (0)70-3177321