CONTROLLER
STANLEY
TB3
TB1
TB4
TB2
TB5
OMD-101
OA-605
OA-605
Door loop OC-905C(S)
Master: Encoder1
(Dipswitch4:OFF)
See section7.
Set dipswitch as shown below.
Dipswitch settings of OMD-101
4312
ON
45678312
ON
Dipswitch1
If setting is ON, after 10 sec. of "Dead Lock" , OC-905C(S) emits Creep Signal.
Dipswitch3
ON : knowing act application, OFF : fully automatic application.
Dipswitch4
ON : "Slave (Encoder2) ", OFF : "Master(Encoder1) ".
When connected a single door (one door), set to OFF.
When connected a double door (two doors), select ON or OFF respectively.
NOTE See ELITE ST specification manual for each dipswitch definitions.
Dipswitch settings of OC-905C(S)
Set dipswitch as shown below.
NOTE See ELITE ST specification manual for each dipswitch definitions.
OMD-101 OC-905C(S)
Placement the Sensor heads
MANUFACTURER'S STATEMENT WARNING
CAUTION
NOTE
Disregard of warning may cause the improper operation causing death or serious injury of a person.
Special attention is required to the section of this symbol.
Disregard of caution may cause the improper
operation
causing injury of a person or damage to objects.
This Installation manual will help identify and resolve some of the most common installation issues. This guide will also
verify that all Dipswitch settings and Area Depth adjustments are properly set. If after verifying all nine steps proper
operation has not been achieved, please contact our Technical Support Team at (800) 877-6656.
ELITE ST
5917330 MAY 2010
Installation manual Read this manual carefully before install. Failure to read this manual may cause improper operation and may result in
serious injury or death of a person.The meanings of the symbols are as follows.
Please study the following first and then read the contents of this manual.
Mounting templates should be aligned with the pivot edge of the door .
Template Labeled "Left Hinge Side".Template Labeled "Right Hinge Side".
NOTE Edge of the template aligned the hinge of door.
Make sure to attach the both templates (Swing Side , Approach Side) on the same horizontal level.
Fix the Sensor heads OMD-101 on MC521 controller
The procedure for OMD-101 is same for that of SENTREX MICRO BOARD
WARNING Turn "Power Switch" on MC521 controller OFF.
1. Remove one of hexagon standoffs from MC521controller.
2. Tight the longer hexagon standoff (ELITE_ST Accessories) .
3. Connect OMD-101 to Sentrex (J401) connector on MC521Controller.
4. Fix the board with the shorter hexagon standoff (ELITE_ST Accessories) .
Wiring
Wiring the cable as shown below.
1. Drill mounting holes and a wiring hole according to the mounting template.
NOTE
Fix the door loop
1. Knockout the side of a cover closer to OA-605.
2. Connect the door loop cable to OA-605.
3. Fix the door loop cover.
Connect pass thru
the communication cable to
both OA-605 sensor heads.
For concealed wiring
For double door connection
Feed the connector. Fix the cover.
For surface wiring.
Knockout the cover.
Supplied flexible wire
shroud is cut to fit on
site.
PUSH
PLATE
For knowing act application, connect purple
wires to push plate (or to Activation sensor).
See section7.
NOTE
On pairs, purple wires from OC-905C(S)s connect
in parallel. Be sure to observe polarity(+ to +, - to -).
Do not connect purple wires to MC-521.
OA-605
OA-605
Door loop OC-905C(S)
Slave: Encoder2
(Dipswitch4:ON)
See section7.
Power Supply (+)
Communication TXD
Communication RXD
Power Supply (-)
: Red
: Green
: White
: Black
TB1 PIN1
TB1 PIN2
TB1 PIN3
TB1 PIN4
OC-905C(S) MC521
CONTROLLER
STANLEY
TB3
TB1
TB4
TB2
TB5
2. Remove the mounting template.
3. Fix the OA-605 sensor heads.
How to remove the cover
Insert the flat head screw driver and push it down.
Hold the top and remove the cover.
Activation
sensor
Make a hole on one side. Door loop will be install on one side only.
All activation devices must be connected to Purple wires.
OC-905C(S)
Fix the cover. Connect cable
Communication cable
0.2m (8")
Communication cable 2.2m (7'3")
Communication cable 2.2m (7'3")
Communication cable
0.2m (8")
Wiring cable 0.6m (2')
Wiring cable 0.6m (2')
Red arrow : Mandatory
Black arrow : See the setting below
Gray arrow : N/A
Black arrow : See the setting below
Gray arrow : N/A
1
2
3
4
5
6 7
Daughter board
OMD-101
1st area depth angle must be set to +5 degrees
(deep).
Area depth angle adjustment
1st row area
Start with 2nd & 3rd area depth angle at +5 degrees (deep).
If after walk test the pattern is too deep, adjust towards
shallow as necessary. After changing the angle adjustment
please repeat Setup process.
(See Setup Process of this document).
2nd & 3rd row area
Dipswitch settings of OA-605
Verify proper dipswitch settings of OA-605 sensor heads (specifically dipswitches 7 & 8 of left bank and 1
thru 8 of right bank).
CAUTION
NOTE See ELITE ST specification manual for each dipswitch definitions.
OA-604
OPERAT ION INDICATOR
SWINGAREA
SENSITIV
POTENTIOMET
MinM
THRESHOLDAREA
SENSITIVITY
POTENTIOMETER
MinMax
5728770
SHALLOW
0deg
-5 deg
DEEP
PATTERN
SHALLOW
PATTERN
DEEP
SHALLOW
SHALLOW
- eg
DEEP
PATTERN
SHALLOW
PATTERN
DEEP
DE
CHSIDE
TheseDipSW [7,8]are onlyfor door mount
RedBlink
Red
Yellow Blink
-
:Doorside Det.
:Presence Det.
:Teaching
Made in Japan
66 7788
1st row area depth Adjustment
DEEP
SHALLOW
+5 deg
0deg
-5 deg
DEEP
PATTERN
SHALLOW
PATTERN
2nd & 3rd row area depth Adjustment
DEEP
SHALLOW
+5 deg
0 deg
-5 deg
DEEP
PATTERN
SHALLO W
PATTERN
Using screwdriver ,
turn both adjust-
ments clockwise
towards "deep"
Setup process
First/Reset Auto Learn :
Operation check Before leaving the site, check five items
Output
Activate
Stall
: ON
: OFF
Entering swing side during opening cycle.
Door stall.
Output
Activate
Stall
: ON
: ON
NOTE Once the door reverses, swing side
door will be actived again.
Output
Activate
Stall
Entering the door at full open position.
Door stay opened.
Output
Activate
Stall
Output
Activate
Stall
Entering approach side during closing cycle.
Door start re-opening.
Output
Activate
Stall
: OFF
: OFF
: ON
: OFF
: ON
: OFF
: ON
: OFF
Output
Activate
Stall
: OFF
: ON
Entering swing side at full closed position.
Door do not open.
Output
Activate
Stall
: ON
: ON
Activate
area
Activate
area
Output
Activate
Stall
: ON
: OFF
Entering approach side at full closed position.
Door open.
Output
Activate
Stall
: ON
: OFF
1. Turn "POWER SWITCH" on MC521 Controller ON, and supply 115VAC to the controller.
2. After supplying 115VAC, WITHIN 4 sec., press "First/Reset Auto Learn Switch" for
approx. 2 sec..
3. After approx. 15 sec., the door opens for 90 degrees, and after a while, the door starts
closing in order to recognize the door position.
4. After approx. 15 sec., the door reopens and closes for 90 degrees, and Elite system
carries out Elite Learning.
5. After approx. 5 sec., the door reopens and closes for the verification.
6. When completed, the Interface LED on OMD-101 goes from Blinking Green to
Solid Green.
When failed to complete, the operation LED shows Green Blinking, and
Encoder LEDs blinks Green and Red alternately. When this occurs,
repeat the procedure above from step "1".
First/Reset Auto Learn Switch
There are 2 ways for a setup.Term Definitions ;
The "Auto Learn" function (similar to Sentrex) which needs to be carried out at
power-supply or when the settings have been changed.
Elite Learning : Same function as "First/Reset Auto Learn" but for Elite System. The function that OA-605
learns the floor change when the door opens.
* Only enabled at the power-supply for the first time or setting change
First/Reset Auto Learn
NOTE
Elite Learning
Approach Side
Initial setup
Do not enter
the detection
area, until
indicator turn
to yellow.
To enable an Elite Learn process only, on either the swing or approach side OA-605 sensor head flip any dipswitch and
then flip it back to the original position (necessary on only one sensor per door panel only).
Check the process as shown below chart.
Door Status OA-605 Operation indicator
Swing Side
Sensor
Status
OC-905C(S)
Operation indicator
Blinking Yellow
Solid Orange
Approx.
6sec.
Blinking Red
Approx.
2sec.
Solid Yellow
Blinking Yellow
Approx. 10sec.
Solid Green
Blinking Green
Approx.
10sec.
Waiting for
next learning Solid Yellow Solid Green
Until activate door
Activate door
to learn
opening cycle
Solid OrangeBlinking Yellow
Learning
full
opened cycle
Blinking Yellow Solid Red
Learning
closing cycle
Blinking Yellow Solid Orange
Setup
complete Solid GreenSolid Green
Until approx.3sec. after
full closed
Until activate door
Until approx.3sec.
after full closed
If more than 5 sec., you must
repeat " initial setup".
NOTE
Dipswitches 7 & 8 of Left bank must be set properly and will be exactly opposite from
approach side to swing side of same panel.
Blinking Red
To pofSwing Doo r
Safety / swing side
45678312
ON
45678312
ON
45678312
ON
Dipswitch setting for sensor #3
45678312
ON
45678312
ON
Area width setting
(Right bank)
45678312
ON
Dipswitch setting for sensor #4
45678312
ON
45678312
ON
45678312
ON
45678312
ON
45678312
ON
45678312
ON
Mode setting
(Left bank)
OR OR
36" Door
42" or
48" Door
OR
OR
Top of Swing Door
Top of Swing Door
Area width setting
(Right bank)
Mode setting
(Left bank)
36" Door
42" or
48" Door
Dipswitch setting for sensor #2
Area width setting
(Right bank)
Dipswitch setting for sensor #1
Mode setting
(Left bank)
36" Door
42" or
48" Door
Area width setting
(Right bank)
Mode setting
(Left bank)
36" Door
42" or
48"Door
Approach / non-swing side
After First/Reset Auto Learn is completed,do not turn "POWER SWITCH"
OFF for minimum of 2 minutes.
NOTE
Red arrow : Mandatory
Black arrow : Select according to your site
Green arrow : Recommendation
Red arrow : Mandatory
Black arrow : Select according to yor site
Green arrow : Recommendation
Using screwdriver ,
turn both adjust-
ments clockwise
towards "deep"
O
A
-
605
Green
Red Blink
Red
Yellow Blink
: Stand-by
: 1st row area detect
: 2nd & 3rd row area
: Learning
OPERATION INDICATOR
IMMUNITY
1ST ROW 2nd & 3rd ROW
1st row area depth Adjustment
2nd & 3rd row area depth Adjustment
1st row area depth Adjustment
DEEP
SHALLOW
+5 deg
0
-5
deg
DEEP
PATTERN
SHALLOW
PATTERN
deg
SHALLOW
DEEP
+5
0
-5
DEEP
2nd & 3rd row area depth Adjustment
DEEP
SHALLOW
deg
deg
deg
SHALLOW
DEEP
PATTERN
SHALLOW
PATTERN
8
9
10
11

Other Optex Accessories manuals

Optex OA-203C User manual

Optex

Optex OA-203C User manual

Optex Prosafe OA-1V User manual

Optex

Optex Prosafe OA-1V User manual

Optex Elite OA-603 User manual

Optex

Optex Elite OA-603 User manual

Optex OA-AXIS T User manual

Optex

Optex OA-AXIS T User manual

Optex OA-PRESENCE T Installation manual

Optex

Optex OA-PRESENCE T Installation manual

Optex OVS-01CC User manual

Optex

Optex OVS-01CC User manual

Optex QA-AXIS II User manual

Optex

Optex QA-AXIS II User manual

Optex OA-FLEX AIR T User manual

Optex

Optex OA-FLEX AIR T User manual

Optex OAM-DUAL II User manual

Optex

Optex OAM-DUAL II User manual

Optex AX-250PLUS User manual

Optex

Optex AX-250PLUS User manual

Optex i-OneX T User manual

Optex

Optex i-OneX T User manual

Optex EZ User manual

Optex

Optex EZ User manual

Optex OA AXIS T User manual

Optex

Optex OA AXIS T User manual

Optex HX-80N User manual

Optex

Optex HX-80N User manual

Optex Pro Swing PREMIER T User manual

Optex

Optex Pro Swing PREMIER T User manual

Optex Redscan Mini User manual

Optex

Optex Redscan Mini User manual

Optex TS-1000-D User manual

Optex

Optex TS-1000-D User manual

Optex OVS-01GT User manual

Optex

Optex OVS-01GT User manual

Optex Reaction One User manual

Optex

Optex Reaction One User manual

Optex V2 Series User manual

Optex

Optex V2 Series User manual

Optex OA-FLEX T User manual

Optex

Optex OA-FLEX T User manual

Optex SIP-3020/5 User manual

Optex

Optex SIP-3020/5 User manual

Optex GEN-DC User manual

Optex

Optex GEN-DC User manual

Optex OA-FLEX T User manual

Optex

Optex OA-FLEX T User manual

Popular Accessories manuals by other brands

Kaiser Baas Pocket Charge 6K quick start

Kaiser Baas

Kaiser Baas Pocket Charge 6K quick start

Radio Bridge RBS306-TILT-HP-US user guide

Radio Bridge

Radio Bridge RBS306-TILT-HP-US user guide

IBM CP20 - Workstation Connection Device KVM installation instructions

IBM

IBM CP20 - Workstation Connection Device KVM installation instructions

INNOBIZ neolia Instructions for use

INNOBIZ

INNOBIZ neolia Instructions for use

Calex PyroUSB Series Operator's guide

Calex

Calex PyroUSB Series Operator's guide

Manitowoc K00341 installation instructions

Manitowoc

Manitowoc K00341 installation instructions

ring VIDEO DOORBELL Setup and installation guide

ring

ring VIDEO DOORBELL Setup and installation guide

Geemarc Doorbell595 U.L.E Quick user guide

Geemarc

Geemarc Doorbell595 U.L.E Quick user guide

X4-Life Video Ski Goggles HD1 user manual

X4-Life

X4-Life Video Ski Goggles HD1 user manual

Logitech Folio i5 Setup guide

Logitech

Logitech Folio i5 Setup guide

Dome Mouser manual

Dome

Dome Mouser manual

AEMC JM850A user manual

AEMC

AEMC JM850A user manual

Philips 22PP3000 brochure

Philips

Philips 22PP3000 brochure

Hornbach 6145082 Installation and user manual

Hornbach

Hornbach 6145082 Installation and user manual

Balluff BCS F01 Series manual

Balluff

Balluff BCS F01 Series manual

Omron SYSMAC C200H-IDS01-V1 Operation manual

Omron

Omron SYSMAC C200H-IDS01-V1 Operation manual

SkyBound 2 ARCH TRAMPOLINE NET Assembly and installation manual

SkyBound

SkyBound 2 ARCH TRAMPOLINE NET Assembly and installation manual

POSIFLEX SD400 Series user manual

POSIFLEX

POSIFLEX SD400 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.