CAUTION
NOTE See ELITE ST specification manual for each dipswitch definitions.
OA-604
OPERAT ION INDICATOR
SWINGAREA
SENSITIV
POTENTIOMET
MinM
THRESHOLDAREA
SENSITIVITY
POTENTIOMETER
MinMax
5728770
SHALLOW
0deg
-5 deg
DEEP
PATTERN
SHALLOW
PATTERN
DEEP
SHALLOW
SHALLOW
- eg
DEEP
PATTERN
SHALLOW
PATTERN
DEEP
DE
CHSIDE
TheseDipSW [7,8]are onlyfor door mount
RedBlink
Red
Yellow Blink
-
:Doorside Det.
:Presence Det.
:Teaching
Made in Japan
66 7788
1st row area depth Adjustment
DEEP
SHALLOW
+5 deg
0deg
-5 deg
DEEP
PATTERN
SHALLOW
PATTERN
2nd & 3rd row area depth Adjustment
DEEP
SHALLOW
+5 deg
0 deg
-5 deg
DEEP
PATTERN
SHALLO W
PATTERN
Using screwdriver ,
turn both adjust-
ments clockwise
towards "deep"
Setup process
First/Reset Auto Learn :
Operation check Before leaving the site, check five items
Output
Activate
Stall
: ON
: OFF
Entering swing side during opening cycle.
Door stall.
Output
Activate
Stall
: ON
: ON
NOTE Once the door reverses, swing side
door will be actived again.
Output
Activate
Stall
Entering the door at full open position.
Door stay opened.
Output
Activate
Stall
Output
Activate
Stall
Entering approach side during closing cycle.
Door start re-opening.
Output
Activate
Stall
: OFF
: OFF
: ON
: OFF
: ON
: OFF
: ON
: OFF
Output
Activate
Stall
: OFF
: ON
Entering swing side at full closed position.
Door do not open.
Output
Activate
Stall
: ON
: ON
Activate
area
Activate
area
Output
Activate
Stall
: ON
: OFF
Entering approach side at full closed position.
Door open.
Output
Activate
Stall
: ON
: OFF
1. Turn "POWER SWITCH" on MC521 Controller ON, and supply 115VAC to the controller.
2. After supplying 115VAC, WITHIN 4 sec., press "First/Reset Auto Learn Switch" for
approx. 2 sec..
3. After approx. 15 sec., the door opens for 90 degrees, and after a while, the door starts
closing in order to recognize the door position.
4. After approx. 15 sec., the door reopens and closes for 90 degrees, and Elite system
carries out Elite Learning.
5. After approx. 5 sec., the door reopens and closes for the verification.
6. When completed, the Interface LED on OMD-101 goes from Blinking Green to
Solid Green.
When failed to complete, the operation LED shows Green Blinking, and
Encoder LEDs blinks Green and Red alternately. When this occurs,
repeat the procedure above from step "1".
First/Reset Auto Learn Switch
There are 2 ways for a setup.Term Definitions ;
The "Auto Learn" function (similar to Sentrex) which needs to be carried out at
power-supply or when the settings have been changed.
Elite Learning : Same function as "First/Reset Auto Learn" but for Elite System. The function that OA-605
learns the floor change when the door opens.
* Only enabled at the power-supply for the first time or setting change
First/Reset Auto Learn
NOTE
Elite Learning
Approach Side
Initial setup
Do not enter
the detection
area, until
indicator turn
to yellow.
To enable an Elite Learn process only, on either the swing or approach side OA-605 sensor head flip any dipswitch and
then flip it back to the original position (necessary on only one sensor per door panel only).
Check the process as shown below chart.
Door Status OA-605 Operation indicator
Swing Side
Sensor
Status
OC-905C(S)
Operation indicator
Blinking Yellow
Solid Orange
Approx.
6sec.
Blinking Red
Approx.
2sec.
Solid Yellow
Blinking Yellow
Approx. 10sec.
Solid Green
Blinking Green
Approx.
10sec.
Waiting for
next learning Solid Yellow Solid Green
Until activate door
Activate door
to learn
opening cycle
Solid OrangeBlinking Yellow
Learning
full
opened cycle
Blinking Yellow Solid Red
Learning
closing cycle
Blinking Yellow Solid Orange
Setup
complete Solid GreenSolid Green
Until approx.3sec. after
full closed
Until activate door
Until approx.3sec.
after full closed
If more than 5 sec., you must
repeat " initial setup".
NOTE
Dipswitches 7 & 8 of Left bank must be set properly and will be exactly opposite from
approach side to swing side of same panel.
Blinking Red
To pofSwing Doo r
Safety / swing side
45678312
ON
45678312
ON
45678312
ON
Dipswitch setting for sensor #3
45678312
ON
45678312
ON
Area width setting
(Right bank)
45678312
ON
Dipswitch setting for sensor #4
45678312
ON
45678312
ON
45678312
ON
45678312
ON
45678312
ON
45678312
ON
Mode setting
(Left bank)
OR OR
36" Door
42" or
48" Door
OR
OR
Top of Swing Door
Top of Swing Door
Area width setting
(Right bank)
Mode setting
(Left bank)
36" Door
42" or
48" Door
Dipswitch setting for sensor #2
Area width setting
(Right bank)
Dipswitch setting for sensor #1
Mode setting
(Left bank)
36" Door
42" or
48" Door
Area width setting
(Right bank)
Mode setting
(Left bank)
36" Door
42" or
48"Door
Approach / non-swing side
After First/Reset Auto Learn is completed,do not turn "POWER SWITCH"
OFF for minimum of 2 minutes.
NOTE
Red arrow : Mandatory
Black arrow : Select according to your site
Green arrow : Recommendation
Red arrow : Mandatory
Black arrow : Select according to yor site
Green arrow : Recommendation
Using screwdriver ,
turn both adjust-
ments clockwise
towards "deep"
O
A
-
605
Green
Red Blink
Red
Yellow Blink
: Stand-by
: 1st row area detect
: 2nd & 3rd row area
: Learning
OPERATION INDICATOR
IMMUNITY
1ST ROW 2nd & 3rd ROW
1st row area depth Adjustment
2nd & 3rd row area depth Adjustment
1st row area depth Adjustment
DEEP
SHALLOW
+5 deg
0
-5
deg
DEEP
PATTERN
SHALLOW
PATTERN
deg
SHALLOW
DEEP
+5
0
-5
DEEP
2nd & 3rd row area depth Adjustment
DEEP
SHALLOW
deg
deg
deg
SHALLOW
DEEP
PATTERN
SHALLOW
PATTERN
8
9
10
11