ファイル名はMacintosh HD:作業:一時置き-進行中:337540オテックス0570491x118Manual:0570491x118-Manual.inddです
#
!
"
'
%$&
%$&
#
!
"
'
#
!
"
'
%$&
%$&
#
!
"
'
Specifications and equipment are subject to
change without any obligations on the part of
manufacture.
For more information, questions and comments
regarding products, please contact us below.
INSTRUCTION
MANUAL
Confirm if the item meets your needs.
Before the use, you should first thoroughly read
this manual and operate correctly as mentioned.
You should keep this manual at hand for proper
use.
Photoelectric Sensor
AC/DC:Relay output
DC:Transistor output
V2 SERIES
・V2T-7000□□□
・V2R-1200□□□
・BGS-2V□□□□
600-8815 Kyoto, Shimogyo, Awata Chudoji 91, Japan
TEL.+81-(0)75-325-2920
FAX.+81-(0)75-325-2921
Website : http://www.optex-fa.com
Manufactured and sold by:
OPTEX FA CO.,LTD.
Through-beam type
1. Install the emitter and the receiver opposite to
each other so that the optical axis lines up.
2. Swing the emitter and the receiver vertically
and from side to side, and x each at the mid-
point in the range where the indicating lamp at
the receiver lights up.
Reection type
Swing the sensor vertically and from side to side,
an and x it at the mid-point In the renge where
the indicating lamp lights up.
◦Adjusting the optical axias.
1.Set the detectable
object at the detection
position and turn the
sensitivity control
slowly from MIN toward
MAX until the output
indicator(orange) lights
up. Call it position A.
2.Remove detectable
object and turn the
sensitivity control
from MAX toward MIN
position where the
output indicator(orange)
is extinguished. Call it position B.
3.Point C midway between A and B is the
optimum sensitivity position.
◦Adjusting the sensitivity control
◦Other precautions
○
No.①~④ corresponds to pin
No. of connector
※Throughbeam 54
Retro‑reflection 29
BGS 54
45
20 5.5
22
12
R34
16°
Outputindicator(Orange)
Stableindicator(Green)
Sens.adjustor
OnlyDCtype
65
70
23.7
M12connector
M4Screw 20
Bracket
36
28.6
60
10
43.9
Opticalaxis*
6.4
2mcableφ6.3(AC/DC)φ3.8(DC)
○ It is dangerous to wire or attach/remove the
connector with the power on.Make sure to turn
off the power before operation.
○ Be careful not to install the sensor at the
following locations, for it may otherwise
malfunction:
• Where a lot of dust, vapor, or the like is preset
• Where corrosive gases are produced
• Where water, oil or the like flies directly onto
the sensor.
• Where strong vibration or shock is caused to
the sensor.
○ The product is not designed for outdoor use.
○ Do not use the sensor in a transient state at
power on.(about 150 ms)
○ Avoid wiring together with high voltage or motor
line in order to prevent the sensor from noise.
○ The performance may depend on the individual
units or the condition of detected product.
○ This product is not an explosion-proof
construction. Do not use the product under
amemable,explosive gas or detected product.
○ Do not use the product in water.
○ Do not disassemble,repair,or convert the
product. Failure to do this may cause
failure,re,or electric shock.
○ Operate within the rated range.
This product cannot be use as a
safety device to protect human body.
!