A. TOP VIEW
B. SIDE VIEW
1.Multi-Level Area
A. TOP VIEW
B. SIDE VIEW
1.Multi-Level Area
2.Pet Alley Area
LX-402 LX-802N
2.DETECTION AREA PATTERNS
This product detects temperature differences between the moving object and the
background temperature in the detection area. So, if the object dose not move,
the detector can not detect it, and changing of the temperature differences may
affect the detector's detection range.
Additionally, since this product has directional characteristic it is difficult to detect
the target that is approaching the detector.
2.Pet Alley Area
FEATURES FUNCTION
·LX-402 :40ft.(12m) 120° Wide Angle
·LX-802N:80ft.(24m) Long Range
·Selectable Detection Area Patterns
·Day/Night Mode
·Waterproof (IP Rating:IP54)
OPTION
·Ceiling Mount Bracket : CA-2C
·Multi-Angle Wall Mount Bracket :CA-1W
Adjust ±45° (Horizontally)
Adjust 0 - 20° (Vertically downwards)
·Selectable Pluse Count ( TEST or 2 )
·Selectable Sensitivity ( H , M or L )
·Form• C Relay Output
·Tamper Switch
LX-402,LX-802N
OUTDOOR PASSIVE INFRARED DETECTOR
120°wide Long Range
No.59-0961-1 010611
1 YEAR WARRANTY
Safety-Related Precautions
This icon indicates actions to be avoid. Details of the actions to be
avoided are written beside or near icon.
·Before installation,•• make sure to read this instruction manual carefully for safe and effective propduct operation.
·After reading this installation instructions, make sure to keep it in a conveninet place for future use.
This icon denotes a situation involving the risk of serious
injury or damage to property if the warning given is ignored.
Caution
This icon denotes a situation involving the risk of serious
injury or even death, if the warning given is ignored.
Warning
This icon indicates instructions that should be strictly followed.
Maximum mounting height is
8.3ft.(2.5m).
Mount the detector directly to a
wall or ceiling with the optional
bracket(model CA-1W or CA-2C).
Avoid moving objects in the
detection area (i.e.swaying
trees, bushes, etc.).
Aim the detector at wall or the ground,
to aviod unwanted detection.
When using the pet alley area,
the mounting height should be
between 4-5ft.(1.2-1.5m).
1.INSTALLATION HINTS
Avoid vapor or high humidity
that can cause condensation.
Avoid looking directly at air
conditioning or heating vents.
4-5 ft.
(1.2-1.5m)
8.3 ft. (2.5m) max
Never use this product for any application expect purpose for••
detecting moving object such as human or car. In addition, never
use for any activation for a shutter or other. It may cause hazards.
Clean and inspect the device periodically for safe operation.
If any defect is detected, ask your local shop to repair the device.
Warning
To avoid the risk of electric shock, never touch the main
body of the product with wet hands (Also, if the product is
wet after rain, do not touch it).
Caution
Never connect the terminal with higher power supply or current
draw over the specification. It increases the risk of fire or damage
to the product.
Never attempt to disassemble or modify the product, which
increases the risk of fire or damage of the product.
Avoid applying water directly from brackets, houses, or otherwise
splashing water directly onto the product. It increases the risk of
damaging the product.
alarm shop

3.DESCRIPTION AND OPERATION
4.INSTALLATION PROCEDURE
5.OPTIONAL BRACKETS
LED Indicater
Lens
cover screw
Day/Night Mode Adjustment
Inner Cover
Pulse Count Switch
Mount Pitch
3.28 Inches (83.5 mm)
Sensitivity Switch
Terminals
(Do not touch)
Sensor
Knockout
Multi-Level/Pet Alley
Adjustment Screw
Installation on wall
Installation on ceiling
13 NOTE ! 5 6 82
Loosen cover screw
and remove cover.
Pull wire throgh the
back of the detector.
If you have prob-
lems of wiring
through the back of
the detector, re-
move adjustment
screw and remove
the PCB from the
base.(see illus.)
Connect wires to
terminals, as shown. Set the Day/Night
mode adjustment
to the “24HR” sett-
ing(DAY).
Set Pulse Count
to “TEST”mode.
Adjust sensitivity
setting (see sec-
tion 6-2 and 3).
Replace the cover
and supply power
to unit.
After the warmup
period is complete
(approx. 60 sec.) ,
conduct Walk Test.
The LED Indicator
lights when the
unit detects mov-
ing object.
Set the Day/Night mode
adjustment to the
NORMAL position(·).
( If night only operaton
is required , see sec-
tion 6-1)
Set Pulse Count to the
“2” position. ( see sec-
tion 6-1 and 2).
After wiring , pack the
provided sponge into
the opening between
each wires and the
knockout hole.
Select HIGH,
MEDIUM or
LOW
sensitivity(H,M,L).
Fasten cover with
the cover screw.
(see section 6-3)
Note ! Maximum mounting height is 8.3 ft (2.5m)
1. Ceiling Mount Bracket “CA-2C”
Adjust Horizontally : ±45° Adjust Vertically : 0° to 20° downward
2. Multi-Angle Wall Mount Bracket “CA-1W”
Adjust Horizontally : ±45° Adjust Vertically : 0° to 20° downward
47After conduct-
ing Walk Test.
Mirror
Photocell
Rubber packing
AWG18
(0.83 mm2)
2700ft
(820m)
AWG20
(0.52 mm2)
1700ft
(510m)
AWG22
(0.33 mm2)
1070ft
(320m)
wires size
inches(mm) inches(mm)
Selectable 3 position
( H, M, L).
Adjust Day/Night Mode according
to desired DAY/NIGHT
operating periods.
If angle adjustment is required, use the
optional “CA-1W” mounting bracket
Use optional ceiling mount bracket ”CA-2C”.
Power supply wires
should not exceed
the following
lengths.
LED lights
during detection.
Loosen screw and select.
For Muli-level : Lower position”M”
For Pet Alley : Upper position”P”
Standard”2”pluse or
“TEST” mode.
Cover
21
Install the bracket
“CA-2C” on ceiling
and pull wire.
Attach the LX-402/
802N to the bracket
and pull wire.
alarm shop

6.SETTING AND ADJUSTMENT
1. Day/ Night Mode
Adjust the Day/Night Mode switch of the detector according to
the brightness of the surrounding area.
: To have the standard detector function
only during evening/night time, set the
dial to the reference position ( · ).
: To have the detector begin to function
while the surrounding area is lighter, turn
the dial gradually to the DAYside.
: To have the detector function only after it
has become dark, turn the dial gradually
to the NIGHT side.
: To have the detector function at all time,
or to perform a walk test, set the dial to
the DAYposition.
2. Pulse Count Swich
“2” mode : Select “2” for normal applications.
(STANDARD Position)
“TEST” mode : Select “TEST” mode when conducting
WALK TEST , or for use in extremely
stable environments.
3. Sensitivity Switch
: Use “M” position for normal applications.
(STANDARD Position)
: Use “H” Position when you need high sensitivity.
(ex.Pet Alley Area)
: Use “L” position in areas that may be unstable.
7.DETECTION• AREA ADJUSTMENT
Changing vertical detection area
1.Multi-Level Area
Use this area for
normal applications.
2.Pet Alley Area
Provide a horizontal
detection pattern with
no declination of zones,
allowing pets to move
through the area.
Unit is pre-set at “Multi-Level” setting.
Selecting Pet Alley Pattern
Carefully loosen the
adjustment screw.
Slide the cover down
and fasten the screw
at the “P” position.
Flip the Mirror to the
upper position.
Eliminating unwanted detection zones
(LX-402 only)
Unwanted detection zones can be eliminated by simply masking
the lens with the provided masking strip, as follows:
Remove cover and apply strip to the
inside of lens on the zone to be
eliminated.(see illus.)
NOTE ! Pet Alley Area will not function if two changes are not
performed.
Unit is pre-set at “M” position.
NOTE ! Sensitivity setting must be one step higher position
when pet alley area is selected.
NORMAL Position
Unit is pre-set at “2” position.
Unit is pre-set at “NORMAL” position.
Example : ZONE “a” can be eliminated by masking the lens at
area “a” (see illus.).
1.
2.
alarm shop

NOTE
This unit is designed to detect moving object and activate an alarm control
panel.Being only part of a complete alarm system,we cannot accept
responsibility for any damages or other consequences resulting from an
intrusion.
This Product conforms to the EMC Directive.89/336 EEC.
This product is NOT a human detector of security purpose.
We recommend our other detectors of security purpose,if you would like
to use detector for security purpose.
inches(mm)
LX-402 LX-802N
8.TROUBLE SHOOTING
9.SPECIFICATIONS 10.DIMENSIONS
PROBLEM PROBABLE CAUSE REMEDY
Improper power supply voltage. ( isconnection, low
voltage) Confirm the power supply is un er specification.
Wrong polarity Switch positive an negative at terminal.
The etector is in warm up perio . Wait for.(approx. 60 sec.)
See section 6-1.
Confirm the a justment knob.
Incorrect etection area. See section 2.
Moving object within area. (curtain, wall hanging, etc.) Remove the object from the etection area.
Improper power supply voltage. Confirm the power supply is un er specification.
LED lights up even though no one The unit is etecting presons, cars or other
is in etection area. objects beyon the set area.
Temperature of object within area is changing rapi ly
(heater, air con itioning, etc.) Remove the heat sources from the etection area.
Check loa of output.
The unit nee s repair or replacement.
Faulty wiring. Wire correctly.
The LED lights up, but there is no Alarm output connects to other evices as follows.
relay output when NC output is use when NC output is use
:connect in parallel. :connect in series.
when NO output is use when NO output is use
:connect in series. :connect in parallel.
Check the etection area.
Relay contact is stuck or amage ue to overloa ing.
LED oes not light up.
The Day/Nigth Mo e A justment knob setting is
inappropriate.
LX-402 LX-802N
40ft×50ft(12m×15m) 80ft×6.6ft(24m×2m)
120°wi e Long range
Multi-Level Area 40 zones 12 zones
Pet Alley Area 18 zones 4 zones
Multi-Level Area
Pet Alley Area
6.0oz (170g) 6.8oz (190g)
Approx. 60 sec.
10.8-13.2VDC
Opens when cover remove .
2 (20±5 sec.) or TEST(1 pulse)
Approx. 10 to 100,000 lux
Mounting
IP54
25 mA max
Wall (In oor/Out oor)
-4°F - +122°F(-20℃ - +50℃)
95% max
Current raw
IP Rating
Passive Infrare
8.3ft (2.5m) max
4-5ft (1.2-1.5m)
1-3.3ft/sec. (0.3-1.0m/sec.)
Selectable 3 position (H,M,L)
LED lights uring etection
2±1 sec.(Delay timer)
NC.NO.28V DC 0.2A max
Accessory Masking strips (LX-402 only),Mounting screw,Sponge
※ Specifications may be change without prior notice for improvements.
Operating temperature
Environment humi ity
Weight
Day/Night Mo e a justment
Warm up perio
Power input
Detection spee
Sensitivity a justment
LED in icator
Alarm perio
Alarm output
Pulse count
Tamper switch
Mo el
Detection metho
Coverage
Mounting height
Detection area
alarm shop
This manual suits for next models
1
Other Optex Security Sensor manuals

Optex
Optex OVS-01GT User manual

Optex
Optex AP-360BR User manual

Optex
Optex RXC-DT-X5 User manual

Optex
Optex RXC-RST User manual

Optex
Optex Fit Series User manual

Optex
Optex CDX-AM Quick start guide

Optex
Optex BX SHIELD User manual

Optex
Optex VX SHIELD Series User manual

Optex
Optex VX-402R User manual

Optex
Optex CX-702 MKII User manual

Optex
Optex CX-502 User manual

Optex
Optex PROWAVE AIR-SLIDE 2 User manual

Optex
Optex CX-702S User manual

Optex
Optex AX-70TN User manual

Optex
Optex VX Infinity Series User manual

Optex
Optex HX-40RAM User manual

Optex
Optex OML-ST User manual

Optex
Optex HX-80N User manual

Optex
Optex OA-EDGE T User manual

Optex
Optex FitLink User manual