manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORiNG
  6. •
  7. Switch
  8. •
  9. ORiNG TGPS-9084GT-M12X-BP2-MV User manual

ORiNG TGPS-9084GT-M12X-BP2-MV User manual

Quick Installation Guide
Version 1.1
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Q I G
ORing's Transporter series managed PoE Ethernet switches are
TM
designed for industrial applications, such as rolling stock, vehicle, and
railway applications. is managed RedundantTGPS-9084GT-M12X-BP2-MV
Ring E t h e r net s w i t c h with 8 x 1 0 /100 / 1 0 0 0Bas e - T (X) P.S . E . and
4x10/100/1000Base-T(X) ports which is specifically designed for the
toughest and fully compliant with EN50155 requirement. The switch
support Ethernet Redundancy protocol, (recovery time < 30ms overO-Ring
250 units of connection), O-Chain, MRP and MSTP/RSTP/STP*NOTE
(IEEE 802.1s/w/D) can protect your mission-critical applications from
network interruptions or temporary malfunctions with its fast recovery
technology. also support Power overTGPS-9084GT-M12X-BP2-MV
Ethernet, a system to transmit electrical power up to 30 watts, along with
data, to remote devices over standard twisted-pair cable in an Ethernet
n e t w o r k . E a c h s w i t c h h a sT G P S - 9 0 8 4 G T - M 1 2 X - B P 2 - M V
8x10/100/1000Base-T(X) P.S.E. (Power Sourcing Equipment) ports. P.S.E.
is a device (switch or hub for instance) that will provide power in a PoE
connection. includes 2 sets of bypass portsTGPS-9084GT-M12X-BP2-MV
that protect the network from failures and Network maintenance by ensuring
network integrity during power loss. And support wide operating
temperature from -40 C to 75 C. can also
o o TGPS-9084GT-M12X-BP2-MV
be managed centralized and convenient by Open-Vision, Except the Web-
based interface, Telnet and console (CLI) configuration. Therefore, the
switch is one of the most reliable choices for EN50155 highly-managed
Ethernet application.
Package Contents
Installation
Wall-mount
The device can be fixed to the wall. Follow the steps below to install the device on the wall.
Step 1: Hold the evice upright against the walld
Step 2: Insert four screws through the large opening of the keyhole-shaped apertures at the
top and bottom of the unit and fasten the screws to the wall with a screwdriver.
Step 3: Slide the evice downwards and tighten the four screws for added stability.d
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative
for assistance.
Preparation
Before you begin installing the device, make sure you have all of the
package contents available and a PC with Microsoft Internet Explorer 6.0 or
later, for using web-based system management tools.
Elevated Operating Ambient: If installed in a closed environment, make sure
the operating ambient temperature is compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Make sure the amount of air flow required for safe
operation of the equipment is not compromised during installation.
Mechanical Loading: Make sure the mounting of the equipment is not in a
hazardous condition due to uneven mechanical loading.
Safety & Warnings
For pin assignments of power, console and relay output ports, please refer to the following tables.
Contents
TGPS-9084GT-M12X-BP2-MV
Pictures Number
1
CD 1
Dimension
Panel Layouts
Front View
1. Reset button
2. Power status LED
3. R.M. status LED
4. Ring status LED
5. Fault LED
6. Power connector
7. Non-PoE Gigabit Ethernet ports (with
bypass for -BP2 model)
8. PoE-enabled Gigabit Ethernet ports
9. Link/ACT LED for non-PoE Gigabit ports
10. Speed LED for non-PoE Gigabit ports
11. Link/ACT LED for PoE-enabled Gigabit
ports
12. PoE indicator for PoE-enabled Gigabit
ports
13. Speed LED for PoE-enabled Gigabit ports
14. Console port
15. Relay output port
Wiring
Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the grounding pin on the power connector to the grounding
surface prior to connecting devices.
Power port pinouts
The device supports two sets of power supplies and uses the M12 S-
coded 4-pin male connector on the front panel for power inputs.
Step 1: Insert a power cable to the power connector on the device.
Step 2: Rotate the outer ring of the cable connector until a snug fit is
achieved. Make sure the connection is tight.
Relay output port pinouts
Relay N.C.
3A@24VDC
Network Connection
The switch has eight 10/100/1000Base-T(X) PoE and four 10/100/1000Base-T(X) non-PoE
Ethernet ports in the form of M12 connector. Depending on the link type, the switch uses CAT 3, 4,
5,5e UTP cables to connect to network devices (PCs, servers, switches, routers, or hubs). Please
refer to the following table for cable specifications.
TGPS-9084GT-M12X-BP2-MV
TGPS-9084GT-M12X-BP2-MV 1907-200-K9084X2MV1-FX011
S w i tc h
E N 5 0 1 5 5
EN50155 12-port managed
Gigabit PoE Ethernet switch
I N D U S T R I A L
1
Instead of screwing the screws in all the way, it is advised
to leave a space of about 2mm to allow room for sliding the
switch between the wall and the screws.
The switch uses the M12 A-coded 5-pin female connector
on the front panel for relay output. Use a cable with an M12
A-coded 5-pin male connector to connect the relay. The
relay contacts will detect user-configured events and form
an close circuit when an event is triggered.
Cable
Type
Max. Length
Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft)
8-pin female M12
X-coding connector
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft)
8-pin female M12
X-coding connector
1000BASE-T Cat. 5/Cat. 5e 100-ohm UTP UTP 100 m (328 ft)
8-pin female M12
X-coding connector
QIG 1
15
14
6
13
11
12
Console port pinouts
RSVD
RXD
RS-23 2, 115200bps, 8, N , 1
GND
TXD
N.C.
3 4 52
7 10
9
8
N.C.
V-
V+
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Ø4. 0
Ø5. 0
Ø8. 0
89. 6
Unit =mm (Tolerance ±0.5mm)
*NOTE: This function is available by request only.
Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Version 1.1
Q I G
Specifications
S w i tc h
E N 5 0 1 5 5
I N D U S T R I A L
1. Launch the Internet Explorer and type in IP address of the device. The default static
IP address is 192.168.10.1
Follow the steps below to log in and access the system:
2. Log in with default user name and password (both are ).admin
3. After logging in, you should see the following screen. For more information on
configurations, please refer to the user manual. For information on operating the
device using ORing’s Open-Vision management utility, please go to ORing website.
Resetting
Configurations
After installing the and connecting cables, he green power LEDswitch t
should turn on. Please refer to the following tablet for LED indication.
Power
Redu nd ant Input Power
Physical Chara cteristic
Enclosure IP-30, Aluminum
Dimension (W x D x H) 26 0(W) x 89.6(D) x 216(H) mm (10.24 x 3.53 x 8.50 in ch.)
Weight (g)
Environmenta l
-40 to 85 C (-40 to 185 F )
o o
Storage Temperature
5% t o 95 % Non-condensing
Operating Humidity
Regulatory App rovals
CE EMC (EN 55024, EN 55032), FCC Part 15B, EN 50155(EN 50121-1, EN 50121-3-2)
EMC
EN 55024 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS),IEC/EN 61000-4-4 (EFT),
IEC/EN 61000-4-5 (Surge), IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2-27
Shock
IEC60068-2-31
IEC60068-2-6
Vibration
Free Fall
MTBF
EN60950-1
Safety
Fault Contact
Relay Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin M12 A-c od in g)
Overload Current Protec ti on
Revers e Polarity P ro tection Present
-40 to 75 C (-40 to 167 F )
o o
Operating Tempe rature
ORing Switch Model
10/100/1000 Base-T(X ) Ports
in M12 Auto MDI/MDIX with
P.S.E.
8 x M12 connect or (8 pin X-coding)
Physical Ports
Technology
Ethernet Standard s
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base -TX
IEEE 802.3ab for 1000 Ba se -T
IEEE 802.3x for Flow co nt rol
IEEE 802.3ad for LACP ( Li nk A ggregation Contro l Pr otocol)
IEEE 802.1p for COS (Cl as s of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spa nn ing Tree Pr ot ocol)
IEEE 802.1s for MSTP (M ul tiple Spanning Tree Protocol)
IEEE 802.1x for Authent ic ation
IEEE 802.1AB for LLDP (Li nk L ay er D iscovery Protocol)
IEEE 802.3af PoE specificatio n
IEEE 802.3at PoE specificatio n
8K
MAC Table
8
Priority Queues
10/100/1000Base -T( X) p orts
in M12
Store-and-Forward
Processing
Sw itch Properties
Sw itching latency: 4.9 us
Sw itching bandwidth: 24 G bp s
Max. Number of Ava ilable VLANs: 4095
IGMP multicast grou ps : 128 for each VLAN
Port rate limi ti ng: User Define
Security Features
Device Binding securi ty f eature
Enable/disable po rt s, MAC based port securit y
Port b as ed network access contr ol ( 802.1x)
VLAN (802.1Q) to segr eg ate and secure network traffi c
Radi us c entralized password manag em ent
SNMPv3 encrypted au th entication and access s ec urity
Https / SSH enhance network s ec urity
Software Fea tures
STP/RSTP/MSTP (IE EE 8 02.1D/w/s)
Redu nd ant Ring (O-Ring) wit h re co ve ry t ime less than 30ms over 250unit s
TOS/ Di ffserv supported
Quality of Service (802 .1 p) for real-time traffic
VLAN (802.1Q) with VLAN t ag ging and GVRP support ed
IGMP Snooping
IP based bandwidth ma na gement
Application based Q oS m an agement
DOS/DDOS auto preventio n
Port c on figura tion, status, stati st ics, monitoring, se cu rity
DHCP Server / Client suppor t
SMTP Client
Modbus TCP
Network Redundancy
O-Ring
O-Chain
MRP*NOTE
MSTP (RSTP/STP comp at ible)
Total PoE budget
LED
Color
Status
Description
PWR Green On DC power module activated
R.M Green On Device operating in Ring Master mode
Ring Green
On Ring enabled
Blinking Ring structure is broken
Fault Amber On Errors occur (i.e. power failure or port malfunctioning)
10/100/1000Base-T(X) P.S.E Ethernet ports
LNK/ACT Green On Port is linked
Blinking Transmitting data
PoE Green On Power supplied over Ethernet
Speed
Green On Port is running at 1000Mbps
Amber On Port is running at 100Mbps
Green/Amber Off Port is running at 10Mbps
10/100/1000Base-T(X) Ethernet ports
LNK/ACT Green On Port is linked
Blinking Transmitting data
Speed
Green On Port is running at 1000Mbps
Amber On Port is running at 100Mbps
Green/Amber Off Port is running at 10Mbps
4 x M12 connect or (8-pin X-coding with 2 x bypass func tion included)
Up to 9.6K Bytes
Jumbo frame
RS-232 Serial Conso le Port RS-232 in M12 (A-coding) connector with console cable. 11 52 00 bp s, 8 , N, 1
Powe r Co nsumption(Typ.)
*P .S E. i s no t in cl ud ed.
EN50155 12-port managed
Gigabit PoE Ethernet switch
ORing Industrial Networking Corp.
Copyright© 2018 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
*NOTE: This function is available by request only.
TGPS-9084GT-M12X-BP2-MV
72 /110 (50.4~137.5VDC) VDC on 4-pin male S-coding connector
95 Watts
25 35 g
Warranty
5 ye ar s
20 2,630 hrs
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Par t 15 B cl as s A
EMI
EN 50155 (IEC 61373)
Other
6
5
7
3
2
1
8
4
10/100/1000Base-T(X) M12 X-coding
Pin No.
Pin Definition
#1
BI_DA+
#2
BI_DA-
#3
BI_DB+
#4
BI_DB-
#5
BI_DD+
#6
BI_DD-
#7
BI_DC-
#8
BI_DC+
10/100/1000Base-T(X) P.S.E. M12
X-coding
Pin No.
Pin Definition
#1
BI_DA+ with PoE Vout+
#2
BI_DA- with PoE Vout+
#3
BI_DB+ with PoE Vout-
#4
BI_DB- with PoE Vout-
#5
BI_DD+
#6
BI_DD-
#7
BI_DC-
#8
BI_DC+
Present
For pin assignments of the Ethernet ports, please refer to the following tables.
TGPS-9084GT-M12X-BP2-MV
TGPS-9084GT-M12X-BP2-MV
To reboot the switch, press the button less than 5 seconds.Reset
To restore the switch configurations back to the factory defaults, press the button more than 5Reset
seconds.
Reset Function
Rese t Bu tton < 5 se c: S ys te m re bo ot , > 5 se c: Factory default
≤8Watts, 72VDC/0.35A (7.56W), 96VDC/0.28A (7.56W), 110VDC/0.25A (7.56W)

Other ORiNG Switch manuals

ORiNG IGS-1050A User manual

ORiNG

ORiNG IGS-1050A User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG IGS-9844 User manual

ORiNG

ORiNG IGS-9844 User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG TGPS-9084GT-M12 User manual

ORiNG

ORiNG TGPS-9084GT-M12 User manual

ORiNG RGS-9244GP User manual

ORiNG

ORiNG RGS-9244GP User manual

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG IDS-342GT User manual

ORiNG

ORiNG IDS-342GT User manual

ORiNG IGS-9084GP-FB2 User manual

ORiNG

ORiNG IGS-9084GP-FB2 User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG RES-1242P User manual

ORiNG

ORiNG RES-1242P User manual

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG IES-1041FX-MM-SC User manual

ORiNG

ORiNG IES-1041FX-MM-SC User manual

ORiNG IGPS-9822DGP+ User manual

ORiNG

ORiNG IGPS-9822DGP+ User manual

ORiNG TGS-1080-M12 Series User manual

ORiNG

ORiNG TGS-1080-M12 Series User manual

ORiNG IGPS-1080A User manual

ORiNG

ORiNG IGPS-1080A User manual

ORiNG IGS-3044GC User manual

ORiNG

ORiNG IGS-3044GC User manual

ORiNG IES-3160 User manual

ORiNG

ORiNG IES-3160 User manual

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG TPS-141TX-M12 Series User manual

ORiNG

ORiNG TPS-141TX-M12 Series User manual

Popular Switch manuals by other brands

Denon AVS-3 owner's manual

Denon

Denon AVS-3 owner's manual

Vito Agro VIIPMA instruction manual

Vito Agro

Vito Agro VIIPMA instruction manual

IFM Electronic ZB0050 operating instructions

IFM Electronic

IFM Electronic ZB0050 operating instructions

Danfoss RT 260A installation guide

Danfoss

Danfoss RT 260A installation guide

Dell PowerConnect W-620 Specifications

Dell

Dell PowerConnect W-620 Specifications

Microsonic zws-15/CD/QS operating instructions

Microsonic

Microsonic zws-15/CD/QS operating instructions

Kobold RFS operating instructions

Kobold

Kobold RFS operating instructions

Belkin OmniView Dual-User PRO3 Specifications

Belkin

Belkin OmniView Dual-User PRO3 Specifications

FS S3150-8T2FP Configuration guide

FS

FS S3150-8T2FP Configuration guide

AMX NXC-HS quick start guide

AMX

AMX NXC-HS quick start guide

Enterasys Vertical Horizon VH-2402S Release notes

Enterasys

Enterasys Vertical Horizon VH-2402S Release notes

TRENDnet TE100-S22 Specifications

TRENDnet

TRENDnet TE100-S22 Specifications

Allied Telesis Rapier 48w Hardware installation guide

Allied Telesis

Allied Telesis Rapier 48w Hardware installation guide

klemko 840005 LIGHTGUARD quick start guide

klemko

klemko 840005 LIGHTGUARD quick start guide

LEGRAND Wattstopper CS-50 manual

LEGRAND

LEGRAND Wattstopper CS-50 manual

NETGEAR ProSafe GS105 installation guide

NETGEAR

NETGEAR ProSafe GS105 installation guide

Moxa Technologies EtherDevice EDS-P510 Series Hardware installation guide

Moxa Technologies

Moxa Technologies EtherDevice EDS-P510 Series Hardware installation guide

Huawei S1720 Quick Maintenance Guide

Huawei

Huawei S1720 Quick Maintenance Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.