manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORiNG
  6. •
  7. Switch
  8. •
  9. ORiNG IGPS-1080A User manual

ORiNG IGPS-1080A User manual

P1 P2 Fau lt
IGPS-1080A
3
4
10/10 0/100 0T
1
2
7
8
5
6
PWR- 1PWR- 2
V2- V2 + V1- V1 +
1A@2 4V DC 50 -57V
G
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Safety & Warnings
Dimension
Panel Layouts
1. PWR indicators
2. Faulty relay indicator
3. Link/Act LED for Gigabit
PoE LAN ports
4. PoE LED for LAN ports
5. Gigabit PoE LAN ports
Package Contents
Front View
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
Installation
Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1: Screw the wall-mount kit onto the rear panel of the switch. A total of six
screws are required, as shown below.
Step 2: Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Step 3: Insert a screw head through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the screws for added stability.
Wall-mounting
Q I G 1907-200-H1080AXXX1-FX016
Reduced Air Flow: Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mechanical Loading: Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3,4,5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Types and Specifications:
Unit =mm (Tolerance ±0.5mm)
Features
Contents
Wall-mount Kit
DIN-rail Kit
IGPS-1080A
Pictures Number
X 2
X 1
QIG X 1
X 1
6-pin terminal block X 1 3
4
5
Rear View
1
1. Din-rail screw holes
Top Panel
1. Wall-mount screw holes
2. Terminal blocks: PWR1, PWR2
, Relay
3. DIP Switch
4. Ground wire.
2 3
4
1
1
is unmanaged PoE Ethernet switch with P.S.E. function.IGPS-1080A IGPS-1080A
supports Power over Ethernet, a system to transmit electrical power, along with data, to
remote devices over standard twisted-pair cable in an Ethernet network. IGPS-1080A
switch has 8X10/100/1000Base-T(X) P.S.E. (Power Sourcing Equipment) ports. P.S.E. is
a device (switch or hub for instance) that will provide power in a PoE setup. The wide
operating temperature range from -40 C to 75 C can satisfy most of operating
o o
environment. Therefore, the switch is one of the most reliable choices for PoE Ethernet
application.
Provide 8x10/100/1000Base-T(X) PoE (P.S.E.) ports
Support P.S.E. based on IEEE 802.3at standard up to 30 Watts per port
Supports jumbo frame up to 9720 Bytes
Support auto-negotiation and auto-MDI/MDI-X
Support full/half-duplex transmission
Support store and forward transmission
Support flow control
Slim type rigid IP-30 housing design
DIN-Rail and wall mounting enabled
IGPS-1080A
94.9
68.15
8.0
14.0 6.05
25.0
50.0
25.5
8.5
25.6
24.3
Ø5.9
Ø3.0
26.1
144.3
12.3
13.1
24.3
Ø4.0
12
IGPS-1080A
Version 1.6
Quick Installation Guide
Industrial Unmanaged Gigabit PoE Switch
P1 P2 Faul t
IGPS-1080A
3
4
10/10 0/1000 T
1
2
7
8
5
6
P1 P2 Faul t
IGPS-1080A
3
4
10/100/1000T
1
2
7
8
5
6
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
G I G A B I T
I N D U S T R I A L
S W I T C H
P o E
Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Q I G
G I G A B I T
I N D U S T R I A L
S W I T C H
P o E
DIP Switch Setting
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2 1A@24V
V2- V2+ V1- V1+
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer
to the following tablet for LED indication.
Specifications
For pin assignments for different types of cables, please refer to the following
tables.
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
Version 1.6
10/100Base-T(X) P.S.E. RJ-45 port
Pin No.
Description
#1
TD+ with PoE Power Input +
#2
TD- with PoE Power Input +
#3
RD+ with PoE Power Input -
#4
N.C.
#5
N.C.
#6
RD- with PoE Power Input -
#7
N.C.
#8
N.C.
1000Base-T P.S.E. RJ-45 port
Pin No.
Description
#1
BI_DA+ with PoE Power Input +
#2
BI_DA- with PoE Power Input +
#3
BI_DB+ with PoE Power Input -
#4
BI_DC+
#5
BI_DC-
#6
BI_DB- with PoE Power Input -
#7
BI_DD+
#8
BI_DD-
LED
Color
Status
Description
P1 Green On DC power 1 activated
P2 Green On DC power 2 activated
Fault Amber On Faulty relay (power failure or port disconnected)
10/100/1000Base-T(X) Gigabit PoE Ethernet ports
LNK/ACT
Green On Port link at 1000Mbps
Amber On Port link at 10/100Mbps
PoE Green On Power supplied over Ethernet
IGPS-1080A Industrial Unmanaged Gigabit PoE Switch
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
LED Indicators
Green: Po wer LED x2Power in d i cator
10/100/1000 Base -T(X) P.S.E.
Por t in RJ45 Auto MDI/MD IX
IGPS-1080A
8
IEEE 802.3 for 1 0Base-T
IEEE 802.3u fo r 100Base -TX
IEEE 802.3ab f or 1000Ba se-T
IEEE 802.3x fo r Flow cont rol
IEEE 802.3at PoE spe cificat ion (up to 30 Watts per port for P.S.E.)
MAC Table 4K MAC addresses
Environmental
-40 to 85 C (-40 to 185 F)
o o
Storage Temperature
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
CE EMC (EN 55024, EN 55032), FCC Part 15 BEMC
EN 55024 (IEC/EN 61000-4-2(ESD),IEC / E N 61000-4-3 (R S ) , IEC/EN 6100 0 - 4-4(EF T),
IEC/EN 61000-4-5 (Surge), IEC/EN 6100 0 - 4-6 (CS), IEC / E N 61000-4-8( P F MF),
IEC/EN 61000-4-11(DIP))
EMS
IEC 60068-2-27Shock
IEC 60068-2-31
IEC 60068-2-6Vibration
Free Fall
Warranty
5 years
-40 to 75 C (-40 to 167 F)
o o
Amber: Indicate PWR1 or PWR2 failure
Fault indicator
Fault contact
Relay Relay output to carry capacity of 1A at 24 VDC
Power
Redun d a nt Input power
Power c o n sumption(Typ.) 6 Watts (PoE output not included)
Overload current protection
Reverse polar i t y p r o tection
Present
Present
Physical Characteristic
Enclosure IP-30 Metal
Dimension (W x D x H)
Weight (g) 44 2 g
Dual DC inputs 50-57VDC on 6-pin terminal block
26.1(W)x94.9(D)x144.3(H) mm (1.03x3 . 7 4x5.68inch . )
10/100/1000Base-T(X) RJ45 port
indicator and PoE indicator
Upper for Lick/Act indicator, Green for 1G, Ambe r f o r 1 0/100Mbps
Lower for Po E indicator, Gree n f o r PoE power injected.
DIP-Switch
Power-2 faile d warnin g : ( O N) enable, (OF F ) d i sableDIP-Switch 1
Power-1 faile d warnin g : ( O N) enable, (OF F ) d i sable
DIP-Switch 2
Processing Store-and-Forward
Jumbo Frame Up to 9KBytes
PoE out p u t power 180 Watts
MTBF
665276hrs
Note : HW version 5.0
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3 - 3 , FCC Part 15 B class AEMI
EN 60950-1
Safety
Packet buffer si ze 192K Bytes
Switch Latency <7us
Switching Bandwidth 16Gbps
IGPS-1080A
DIP-2
OFF
OFF
DIP-1
Power failure relay alarm disabled
PWR-1 failure, relay alarm enabled
PWR-2 failure, relay alarm enabled
OFF
ON
Description
ON PWR-1 or PWR-2 failure,
relay alarm enabled
ON
ON
OFF

Other ORiNG Switch manuals

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG IGS-9084GP User manual

ORiNG

ORiNG IGS-9084GP User manual

ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54 User manual

ORiNG

ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54 User manual

ORiNG IBS-102FX User manual

ORiNG

ORiNG IBS-102FX User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

ORiNG IGPS-9080-24V User manual

ORiNG

ORiNG IGPS-9080-24V User manual

ORiNG IGPS-9084GP-LA User manual

ORiNG

ORiNG IGPS-9084GP-LA User manual

ORiNG RGS-7244GP User manual

ORiNG

ORiNG RGS-7244GP User manual

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG RGS-R9004GP+ME-HV User manual

ORiNG

ORiNG RGS-R9004GP+ME-HV User manual

ORiNG RGS-7244GP User manual

ORiNG

ORiNG RGS-7244GP User manual

ORiNG IGS-9168GP series User manual

ORiNG

ORiNG IGS-9168GP series User manual

ORiNG IES-180-L User manual

ORiNG

ORiNG IES-180-L User manual

ORiNG IGS-9084GP-LA User manual

ORiNG

ORiNG IGS-9084GP-LA User manual

ORiNG IPS-3082GC-24V User manual

ORiNG

ORiNG IPS-3082GC-24V User manual

ORiNG IPS-2042TX Series User manual

ORiNG

ORiNG IPS-2042TX Series User manual

ORiNG IPS-1042FA-MM-SC User manual

ORiNG

ORiNG IPS-1042FA-MM-SC User manual

ORiNG IGPS-1082GP Series User manual

ORiNG

ORiNG IGPS-1082GP Series User manual

ORiNG IGS-9812GP User manual

ORiNG

ORiNG IGS-9812GP User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG TES-250-M12 User manual

ORiNG

ORiNG TES-250-M12 User manual

ORiNG IES-1080A User manual

ORiNG

ORiNG IES-1080A User manual

ORiNG IGS-9122GPM User manual

ORiNG

ORiNG IGS-9122GPM User manual

Popular Switch manuals by other brands

Ubiquiti UniFi US-24-250W quick start guide

Ubiquiti

Ubiquiti UniFi US-24-250W quick start guide

Sonoff ZigBee DIY BASICZBR3 Quick installation guide

Sonoff

Sonoff ZigBee DIY BASICZBR3 Quick installation guide

Shinybow USA SB-5645LCM-CT instruction manual

Shinybow USA

Shinybow USA SB-5645LCM-CT instruction manual

CM Labs Sixtyfour owner's manual

CM Labs

CM Labs Sixtyfour owner's manual

VERIS INDUSTRIES, INC. Hawkeye 806 installation guide

VERIS INDUSTRIES, INC.

VERIS INDUSTRIES, INC. Hawkeye 806 installation guide

CTC Union ITP-1204GTM-12PHE Quick installation guide

CTC Union

CTC Union ITP-1204GTM-12PHE Quick installation guide

hager HXE030H User instructions

hager

hager HXE030H User instructions

NETGEAR ProSafe GS516TP installation guide

NETGEAR

NETGEAR ProSafe GS516TP installation guide

Supermicro SSE-G48-TG4 Quick configuration guide

Supermicro

Supermicro SSE-G48-TG4 Quick configuration guide

Panasonic ESP Series Specification sheet

Panasonic

Panasonic ESP Series Specification sheet

Belkin Switch2 DVI-D user manual

Belkin

Belkin Switch2 DVI-D user manual

Techlogix TL-SM3X1-HDV user manual

Techlogix

Techlogix TL-SM3X1-HDV user manual

Aruba AT-8400 SERIES user guide

Aruba

Aruba AT-8400 SERIES user guide

TRENDnet TK-208K user guide

TRENDnet

TRENDnet TK-208K user guide

Alaxala AX6300S series quick start guide

Alaxala

Alaxala AX6300S series quick start guide

Banner SI-RFST-UP8 instruction manual

Banner

Banner SI-RFST-UP8 instruction manual

LevelOne FEP-0531 user manual

LevelOne

LevelOne FEP-0531 user manual

Cisco ME-C3750-24TE-M Hardware installation guide

Cisco

Cisco ME-C3750-24TE-M Hardware installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.