Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Q I G
G I G A B I T
I N D U S T R I A L
S W I T C H
P o E
DIP Switch Setting
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2 1A@24V
V2- V2+ V1- V1+
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer
to the following tablet for LED indication.
Specifications
For pin assignments for different types of cables, please refer to the following
tables.
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
Version 1.6
10/100Base-T(X) P.S.E. RJ-45 port
TD+ with PoE Power Input +
TD- with PoE Power Input +
RD+ with PoE Power Input -
RD- with PoE Power Input -
1000Base-T P.S.E. RJ-45 port
BI_DA+ with PoE Power Input +
BI_DA- with PoE Power Input +
BI_DB+ with PoE Power Input -
BI_DB- with PoE Power Input -
P1 Green On DC power 1 activated
P2 Green On DC power 2 activated
Fault Amber On Faulty relay (power failure or port disconnected)
10/100/1000Base-T(X) Gigabit PoE Ethernet ports
LNK/ACT
Green On Port link at 1000Mbps
Amber On Port link at 10/100Mbps
PoE Green On Power supplied over Ethernet
IGPS-1080A Industrial Unmanaged Gigabit PoE Switch
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
LED Indicators
Green: Po wer LED x2Power in d i cator
10/100/1000 Base -T(X) P.S.E.
Por t in RJ45 Auto MDI/MD IX
IGPS-1080A
8
IEEE 802.3 for 1 0Base-T
IEEE 802.3u fo r 100Base -TX
IEEE 802.3ab f or 1000Ba se-T
IEEE 802.3x fo r Flow cont rol
IEEE 802.3at PoE spe cificat ion (up to 30 Watts per port for P.S.E.)
MAC Table 4K MAC addresses
Environmental
-40 to 85 C (-40 to 185 F)
o o
Storage Temperature
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
CE EMC (EN 55024, EN 55032), FCC Part 15 BEMC
EN 55024 (IEC/EN 61000-4-2(ESD),IEC / E N 61000-4-3 (R S ) , IEC/EN 6100 0 - 4-4(EF T),
IEC/EN 61000-4-5 (Surge), IEC/EN 6100 0 - 4-6 (CS), IEC / E N 61000-4-8( P F MF),
IEC/EN 61000-4-11(DIP))
EMS
IEC 60068-2-27Shock
IEC 60068-2-31
IEC 60068-2-6Vibration
Free Fall
Warranty
5 years
-40 to 75 C (-40 to 167 F)
o o
Amber: Indicate PWR1 or PWR2 failure
Fault indicator
Fault contact
Relay Relay output to carry capacity of 1A at 24 VDC
Power
Redun d a nt Input power
Power c o n sumption(Typ.) 6 Watts (PoE output not included)
Overload current protection
Reverse polar i t y p r o tection
Present
Present
Physical Characteristic
Enclosure IP-30 Metal
Dimension (W x D x H)
Weight (g) 44 2 g
Dual DC inputs 50-57VDC on 6-pin terminal block
26.1(W)x94.9(D)x144.3(H) mm (1.03x3 . 7 4x5.68inch . )
10/100/1000Base-T(X) RJ45 port
indicator and PoE indicator
Upper for Lick/Act indicator, Green for 1G, Ambe r f o r 1 0/100Mbps
Lower for Po E indicator, Gree n f o r PoE power injected.
DIP-Switch
Power-2 faile d warnin g : ( O N) enable, (OF F ) d i sableDIP-Switch 1
Power-1 faile d warnin g : ( O N) enable, (OF F ) d i sable
DIP-Switch 2
Processing Store-and-Forward
Jumbo Frame Up to 9KBytes
PoE out p u t power 180 Watts
MTBF
665276hrs
Note : HW version 5.0
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3 - 3 , FCC Part 15 B class AEMI
EN 60950-1
Safety
Packet buffer si ze 192K Bytes
Switch Latency <7us
Switching Bandwidth 16Gbps
IGPS-1080A
DIP-2
OFF
OFF
DIP-1
Power failure relay alarm disabled
PWR-1 failure, relay alarm enabled
PWR-2 failure, relay alarm enabled
OFF
ON
Description
ON PWR-1 or PWR-2 failure,
relay alarm enabled
ON
ON
OFF