IGPS-9042GP
PWR
PWR1
PWR2
R.M
Ring
Fault
G3
G4
G1
G2
Reset
1
2
3
4
802.3at/af PoE
G6
100/1000X
G5 G6
10/100/1000T
G5
Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
The is a full-Gigabit managed PoE Ethernet switch with
four 10/100/1000Base-T(X) P.S.E. ports and two 100/1000Base-X SFP
ports. The former supports IEEE 1588v2 clock synchronization while the
latter does not. With complete support for Ethernet redundancy protocols
such as O-Ring (recovery time < 30ms over 250 units of connection) and
MSTP (RSTP/STP compatible), the device can protect mission-critical
applications from network interruptions or temporary malfunctions with fast
recovery technology. The four 10/100/1000Base-T(X) P.S.E. ports enable
the device to provide sufficient power for power-hungry devices with up
to 30w per port. With a wide operating temperature from -40 C to 75 C, the
device can be managed centrally via ORing’s proprietary Open-Vision
platform as well as via Web-based interfaces, Telnet and console (CLI).
IGPS-9042GP-24V
oo
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient:
Reduced Air Flow:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Safety & Warnings
Dimension
Panel Layouts
12
1. Reset button
2. PWR status LED
3. PWR1 LED
4. PWR2 LED
5. R.M. status LED
6. Ring status LED
7. Faulty relay indicator
8. Console port
9. PoE indicators for LAN ports
10. SFP Ports
11. Link/Act LED for SFP ports
12. Gigabit PoE LAN ports
13. Link/Act LED for Gigabit LAN
ports
14. Speed LED for LAN ports
Package Contents
Contents
DIN-rail Kit
CD
IGPS-9042GP-24V
Pictures Number
X1
X1
X1
Front View
Top Panel
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
QIG
Console Cable
X1
X1
X1
Wall-mount Kit
13
Rear View
12
1
1. Wall-mount screw holes
2. Din-rail screw holes
1. Terminal blocks: PWR1, PWR2
, Relay
1
Installation
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the wall-mount kit onto the rear panel of the switch. A total of six
screws are required, as shown below.
Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert a screw head through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the screws for added stability.
Wall-mounting
IGPS-9042GP-24V
QIG IGPS-9042GP-24V 1907-2-29-IGPS9042GP-1.0
Mechanical Loading:
Circuit Overloading:
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3,4,5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
54.3
32.2
45.0
14.0
40.0
50.0
25.3
33.6
12.5
54.3
145.1
108.5
32.0
32.2
116.0
18.0 18.15
51.0
209.3 7.35
187.4
R2.5
R3.95
46.0
8
2
3
4
5
6
7
1
GIGABIT
INDUSTRIAL
SWITCH
PoE
Industrial Managed PoE Gigabit Switch
9
IGPS-9042GP
PWR
PWR1
PWR2
R.M
Ring
Fault
G3
G4
G1
G2
Reset
1
2
3
4
802.3at/af PoE
G6
100/1000X
G5 G6
10/100/1000T
G5
IGPS-9042GP
PWR
PWR1
PWR2
R.M
Ring
Fault
G3
G4
G1
G2
Reset
1
2
3
4
802.3at/af PoE
G6
100/1000X
G5 G6
10/100/1000T
G5
10
11
14
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Power
Redundant Input power
Power consumption(Typ.)
(PoE output not included) 9.4 watts
Overload current protection Present
Physical Characteristic
Enclosure IP-30
Dimension(WxDxH) 54.1(W)x106.1(D)x145.4(H) mm (2.13x4.18x5.72 inch.)
RS-232 Serial Console Port
Switch Properties
Switchlatency:7us
Switch bandwidth: 12Gbps
Max. Number of Available VLANs: 4095
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server / Client support
SMTP Client
Modbus TCP
Network Redundancy O-Ring, Open-Ring, O-Chain, MRP, MSTP (RSTP/STP compatible)
RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1
Weight (g) 765 g
Jumbo frame Up to 9.6K Bytes
Weight (g) 710 g 740 g722 g 735 g 735 g 740 g
Environmental
-40to85 C(-40to185 F)
oo
Storage Temperature
-40to75 C(-40to167 F)
oo
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
Free Fall
Warranty
5years
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Fault Contact
Relay Relayoutputtocarrycapacityof1Aat24VDC
ReversePolarityProtection
Present
QIG
GIGABIT
INDUSTRIAL
SWITCH
PoE
Industrial Managed PoE Gigabit Switch
1000Base-T P.S.E. RJ-45 Port
Pin No.
BI_DA+ with PoE Power input +
#1
Assignments
#2
#3
#4
BI_DA- with PoE Power input +
BI_DB+ with PoE Power input -
BI_DC+
BI_DC-
#5
#6
#7
#8
BI_DB- with PoE Power input -
BI_DD+
BI_DD-
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X p ort
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3RD+(receive)TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5BI_DC-BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
Resetting
To reboot the switch, press the button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the button for 5 seconds.
Reset
Reset
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you should
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
admin
Follow the steps to set up the switch:
Specifications
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.z for 1000Base-X
IEEE 802.3x for Flow control
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
IEEE 1588v2 clock synchronization
IEEE 802.3at PoE specification (up to 30 Watts per port for P.S.E.)
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1p for COS (Class of service)
10/100/1000Base-T(X) with
P.S.E. Ports in RJ45 Auto
MDI/MDIX
MAC Table 8K
Priority Queues 8
Processing Store-and-Forward
4
IEEE 1588v2 cloclk
synchronization
supported
IGPS-9042GP-24V
PoE Output Watts 12 ~24VDC : 60Watts Max.
24~57VDC:120WattsMax.
Dual DC inputs. 12-57VDC on 6-pin terminal block
100/1000Base-X with SFP port 2
10/100Base-T(X) P.S.E. RJ-45 Port
Pin No.
TD+ with PoE Power input +
#1
Assignments
#2
#3
#6
TD- with PoE Power input +
RD+ with PoE Power input -
RD- with PoE Power input -
LED Color Status Description
PWR Green On DC power on
PWR1 Green On DC power module 1 activated
PWR2 Green On DC power module 2 activated
R.M Green On Ring Master
On Ring enabled
Ring Green Blinking Ring structure is broken (i.e. part of the ring is
disconnected)
Fault Amber On Faulty relay (power failure or port disconnected)
PoE Green On Power supplied over Ethernet
10/100/1000Base-T(X) Gigabit PoE Ethernet ports
On Port link up
LNK/ACT Green Blinking Data transmitted
Green On Port link at 1000Mbps
Amber On Port link at 100MbpsSpeed
Green/Amber Off Port link at 10Mbps
SFP ports
On Port link up
LNK/ACT Green
Blinking Data transmitted
IGPS-9042GP-24V
IGPS-9042GP-24V

Other ORiNG Switch manuals

ORiNG TGPS-9164GT-M12X-BP2-24V User manual

ORiNG

ORiNG TGPS-9164GT-M12X-BP2-24V User manual

ORiNG TPS-1080-M12 User manual

ORiNG

ORiNG TPS-1080-M12 User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG IGS-9812GP User manual

ORiNG

ORiNG IGS-9812GP User manual

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG IGPS-1082GP Series User manual

ORiNG

ORiNG IGPS-1082GP Series User manual

ORiNG RES-1242P User manual

ORiNG

ORiNG RES-1242P User manual

ORiNG TPS-141TX-M12 Series User manual

ORiNG

ORiNG TPS-141TX-M12 Series User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG IPS-1042FX-24V Series User manual

ORiNG

ORiNG IPS-1042FX-24V Series User manual

ORiNG TGPS-9168GT-M12-BP2-24V User manual

ORiNG

ORiNG TGPS-9168GT-M12-BP2-24V User manual

ORiNG IGPS-1411GTPA User manual

ORiNG

ORiNG IGPS-1411GTPA User manual

ORiNG IGPS-R9084GP User manual

ORiNG

ORiNG IGPS-R9084GP User manual

ORiNG IGPS-1080A User manual

ORiNG

ORiNG IGPS-1080A User manual

ORiNG IPS-1042FA-MM-SC User manual

ORiNG

ORiNG IPS-1042FA-MM-SC User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG IES-2050-M12 User manual

ORiNG

ORiNG IES-2050-M12 User manual

ORiNG IGS-9844GPFX Series User manual

ORiNG

ORiNG IGS-9844GPFX Series User manual

ORiNG IES-1041FX-MM-SC User manual

ORiNG

ORiNG IES-1041FX-MM-SC User manual

ORiNG TES-250-M12 User manual

ORiNG

ORiNG TES-250-M12 User manual

ORiNG IES-1050A User manual

ORiNG

ORiNG IES-1050A User manual

ORiNG IES-3162GC Series User manual

ORiNG

ORiNG IES-3162GC Series User manual

ORiNG IBS-102FX User manual

ORiNG

ORiNG IBS-102FX User manual

Popular Switch manuals by other brands

Ross Synergy 1 SD manual

Ross

Ross Synergy 1 SD manual

QSFPTEK S5300-24P4TS quick start guide

QSFPTEK

QSFPTEK S5300-24P4TS quick start guide

Vetra MegaTouch VIP-808-V Series User instructions

Vetra

Vetra MegaTouch VIP-808-V Series User instructions

SMC Networks 6726AL2 - annexe 1 installation guide

SMC Networks

SMC Networks 6726AL2 - annexe 1 installation guide

EtherWAN EX38000 Series quick start guide

EtherWAN

EtherWAN EX38000 Series quick start guide

NTI Splitmux-C5HDR-4LC Installation and operation manual

NTI

NTI Splitmux-C5HDR-4LC Installation and operation manual

Lindy 38268 user manual

Lindy

Lindy 38268 user manual

HPE Aruba 2930M 24SR Product End-of-Life Disassembly Instructions

HPE

HPE Aruba 2930M 24SR Product End-of-Life Disassembly Instructions

Barksdale Dynalco SST7200 Installation and operation manual

Barksdale

Barksdale Dynalco SST7200 Installation and operation manual

Steren SWI-005 user manual

Steren

Steren SWI-005 user manual

NETGEAR GS608v3 installation guide

NETGEAR

NETGEAR GS608v3 installation guide

Elko iNels RFJA-32B-SL quick start guide

Elko

Elko iNels RFJA-32B-SL quick start guide

StarTech.com HBS304A24A quick start guide

StarTech.com

StarTech.com HBS304A24A quick start guide

NETGEAR GS724TS - ProSafe 24 Port Gigabit Stackable Smart... Software administration manual

NETGEAR

NETGEAR GS724TS - ProSafe 24 Port Gigabit Stackable Smart... Software administration manual

Ruijie RG-NBS5100 Series Hardware  installation and reference guide

Ruijie

Ruijie RG-NBS5100 Series Hardware installation and reference guide

3One data IES7110-2GS Series user manual

3One data

3One data IES7110-2GS Series user manual

Tripp Lite B006-004-R user manual

Tripp Lite

Tripp Lite B006-004-R user manual

Watchguard NX3CE12 Hardware guide

Watchguard

Watchguard NX3CE12 Hardware guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.