Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Po we r
Redunda nt I nput powe r
Power con su mption( Typ. ) 10 Watt s
Ov erload cu rrent pro te ction Pr esent
Ph ys ic al C haracteristic
En closure I P- 30
Di mension ( W x D x H) 54 .3(W)x1 08 .5(D)x1 45.1(H) m m (2.13x4 .2 7x5.71 in ch.)
Sw itch Prop erties
Sw itch late ncy: 7 us
Sw itch band width: 12 Gb ps
Weigh t (g) 83 7 g
Ju mbo fra me Up t o 9.6K Byte s
Fa ul t Co nt act
Relay Relay outp ut to carry c apacity o f 1A at 24VDC
Reverse Polari ty Protec tion
Pr esent
Q I G
G I G A B I T
I N D U S T R I A L
S W I T C H
For pin assignments for different types of cables, please refer to the following
tables.
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
Specifications
OR in g Sw it ch Model
Ph ys ic al P orts
Te ch no lo gy
Et hernet St an dards
IE EE 802.3 fo r 10 Base-T
IE EE 802.3u f or 1 00Base-T X and 100Ba se-FX
IE EE 802.3a b fo r 1000Bas e-T
IE EE 802.z fo r 10 00Base-X
IE EE 802.3x f or F low contr ol
10 /100/10 00 Base-T(X ) Ports
in R J45 Auto MD I/MDIX
MA C Tabl e 8K
Packet bu ffer 4M bit
Pr ocessin g St ore-a nd -Fo rward
8
IG S- 10 82 GP
Du al DC input s. 1 2-48VDC o n 6-pin ter minal blo ck
10 0/1000B as e-X w ith SFP por t 2
1000Base-T RJ-45 Port
Pin No.
BI_DA+
# 1
Assignments
# 2
# 3
# 4
BI_DA-
BI_DB+
BI_DC+
BI_DC-
# 5
# 6
# 7
# 8
BI_DB-
BI_DD+
BI_DD-
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2
1A@24V
V2- V2+ V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
10/100Base-T(X) RJ-45 Port
Pin No.
TD+
# 1
Assignments
# 2
# 3
# 6
TD-
RD+
RD-
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
DC power module 1 activated
DC power module 2 activated
Version 1.0
IGS-1082GP
IGS-1082GP Industrial Unmanaged Gigabit Switch
Weigh t (g) 71 0 g 74 0 g72 2 g 73 5 g 73 5 g 74 0 g
En vi ro nm ental
-4 0 to 85 C (-40 to 18 5 F )
o o
St orage Temperature
-4 0 to 75 C (-40 to 16 7 F )
o o
Op erating Tempe rature
5% t o 95% Non-c on densingOp erating H umidity
Re gu la to ry Approvals
CI SPR 32, EN5 50 32, FCC Part 15B cla ss AEM I
IE C 61000-4 -2 ( ESD), IEC 6 1000-4- 3 (RS), IEC 6 10 00-4-4 (E FT ), IEC 6100 0-4-5 (Su rge), IEC 6 10 00-4-6 (C S), IEC 610 00-4-8 (P FM F),
IE C 61000-4 -1 1 (DIP)
EM S
IE C60068- 2- 27Sh ock
IE C60068- 2- 32
IE C60068- 2- 6Vi brati on
EN 60950-1 c om pliant
Sa fety
Fr ee Fa ll
Wa rr an ty
5 ye ars
MT BF ( hr s)
722009hrs
DI P Sw it ch
DI P-Swi tc h 1
DI P-Swi tc h 2 Power-1 f ailed war ning : (ON) e nable, (O FF ) disab le
DI P-Swi tc h 3 DIP switc h 3 an d 4 (ON) : SFP sp eed setti ng to 100Mb ps
LE D In di ca tors
Power Ind ic ator (PWR ) Gr een : Pow er L ED x 3
DI P-Swi tc h 4
DI P switch 3 an d 4 (O FF) : SFP spe ed settin g to 1000Mb ps (defa ul t)
Power-2 f ailed war ning : (ON) e nable, (O FF ) disab le
Fault I ndicato r (Fa ul t) Am ber : Indic at e power fai led eve n warning
10 /100/10 00 Base-T(X ) RJ45
Port Indi ca tor
Gr een for por t Li nk/Act.
Du al color LE D fo r speed ind icator ~ Gr een for 100 0Mbps / Amb er f or 100Mbp s / off-l ight for 10 Mbps
10 0/1000B as e-X S FP Port
In dicator G re en for port L ink/Act .
En 55032, EN 55 024(CE EM C), FCC Part 15B, EN 61000-3 -2, EN610 00 -3-3EM C
ORing Industrial Networking Corp.
Copyright© 2017 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com