Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Th e is a G ig ab it u nm an ag ed Ethernet switch wi thIG S- 10 82 GP
8x10/100/1000Base-T(X) ports and 2x100/1000Base-X SFP ports, ideal for
applications that demand high bandwidth. The device support a wide range
power input between 12~48VDC to satisfy the demands of devices.
Configuration of SFP speed is made easy with a 4-pin DIP switch which can
also be set to send power failure alerts. With a wide operating temperature
range from -40 C to 75 C and dual power inputs, the devices can work
o o
perfectly in harsh environments.
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised
Mounting of the equipment in the rack should beMechanical Loading:
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
Safety & Warnings
Dimension
Panel Layouts
1. Power status LED
2. Fault LED
3. LNK/ACT LED for SFP modules
4. SFP Ports
5. Gigabit LAN ports
6. Link/Act LED for Gigabit LAN
ports
7. Speed LED for Gigabit LAN ports
Package Contents
Contents
DIN-rail Kit
IGS-9042GP
Pictures Number
X 1
X 1
Front View
Top Panel
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
QIG
X 1
X 1
Wall-mount Kit
Rear View
12
1
1. Wall-mount screw holes
2. Din-rail screw holes
1. Terminal blocks: PWR1, PWR2
, Relay
2. DIP switch
1
Installation
Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1: Screw the wall-mount kit onto the rear panel of the switch. A total of six
screws are required, as shown below.
Step 2: Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Step 3: Insert a screw head through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the screws for added stability.
Wall-mounting
Q I G IGS-1082GP 1907-2-29-IGS1082GP-1.0
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3,4,5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable
specifications.
54.3
45.0
14.0
40.0
50.0
25.3
116.0
18.0 18.15
51.0
209.3 7.35
187.4
R2.5
R3.95
46.0
2
1
IGS-1082GP
G I G A B I T
I N D U S T R I A L
S W I T C H
Industrial Unmanaged Gigabit Switch
32.2
33.6
12.5
54.3
145.1
108.5
19.0
32.2
G8
G10
G6 G10
G9
100/1000X
PWR
PWR1
PWR2 Fau lt
LNK/AC K
IGS-1082GP
G6
G4
G2
G7
G5
G3
G1
10/100/1000T
Speed
G8
G10
G6 G1 0
G9
100/ 1000X
PWR
PWR1
PWR2 F ault
LNK/ ACK
IGS-1082GP
G6
G4
G2
G7
G5
G3
G1
10/100/1000T
Spee d
43
6
5
7
2
G8
G10
G6 G10
G9
100/1000X
PWR
PWR1
PWR2 Fa ult
LNK/A CK
IGS-1082GP
G6
G4
G2
G7
G5
G3
G1
10/100/1000T
Speed
Dip Switch
DIP-Switch 1
Power-2 failed warning : (ON) enable, (OFF) disable
DIP-Switch 2
Power-1 failed warning : (ON) enable, (OFF) disable
DIP-Switch 3
DIP switch 3 and 4 (ON) : SFP speed setting to 100Mbps
DIP-Switch 4
DIP switch 3 and 4 (OFF) : SFP speed setting to 1000Mbps(default)
Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Po we r
Redunda nt I nput powe r
Power con su mption( Typ. ) 10 Watt s
Ov erload cu rrent pro te ction Pr esent
Ph ys ic al C haracteristic
En closure I P- 30
Di mension ( W x D x H) 54 .3(W)x1 08 .5(D)x1 45.1(H) m m (2.13x4 .2 7x5.71 in ch.)
Sw itch Prop erties
Sw itch late ncy: 7 us
Sw itch band width: 12 Gb ps
Weigh t (g) 83 7 g
Ju mbo fra me Up t o 9.6K Byte s
Fa ul t Co nt act
Relay Relay outp ut to carry c apacity o f 1A at 24VDC
Reverse Polari ty Protec tion
Pr esent
Q I G
G I G A B I T
I N D U S T R I A L
S W I T C H
For pin assignments for different types of cables, please refer to the following
tables.
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
Specifications
OR in g Sw it ch Model
Ph ys ic al P orts
Te ch no lo gy
Et hernet St an dards
IE EE 802.3 fo r 10 Base-T
IE EE 802.3u f or 1 00Base-T X and 100Ba se-FX
IE EE 802.3a b fo r 1000Bas e-T
IE EE 802.z fo r 10 00Base-X
IE EE 802.3x f or F low contr ol
10 /100/10 00 Base-T(X ) Ports
in R J45 Auto MD I/MDIX
MA C Tabl e 8K
Packet bu ffer 4M bit
Pr ocessin g St ore-a nd -Fo rward
8
IG S- 10 82 GP
Du al DC input s. 1 2-48VDC o n 6-pin ter minal blo ck
10 0/1000B as e-X w ith SFP por t 2
1000Base-T RJ-45 Port
Pin No.
BI_DA+
# 1
Assignments
# 2
# 3
# 4
BI_DA-
BI_DB+
BI_DC+
BI_DC-
# 5
# 6
# 7
# 8
BI_DB-
BI_DD+
BI_DD-
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2
1A@24V
V2- V2+ V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
10/100Base-T(X) RJ-45 Port
Pin No.
TD+
# 1
Assignments
# 2
# 3
# 6
TD-
RD+
RD-
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
LED
Color
Status
Description
PW
Green
On
Power is on
PW1
Green
On
DC power module 1 activated
PW2
Green
On
DC power module 2 activated
Fault
Amber
On
Errors occur
Gigabit Ethernet ports
ACT/LNK
Green
On
Port is connected
Speed
Green
On
Port runs at 1000Mbps
Amber
On
Port runs at 100Mbps
Green/Amber
Off
Port runs at 10Mbps
SFP ports
LNK/LNK
Green
On
Port is connected
Version 1.0
IGS-1082GP
IGS-1082GP Industrial Unmanaged Gigabit Switch
Weigh t (g) 71 0 g 74 0 g72 2 g 73 5 g 73 5 g 74 0 g
En vi ro nm ental
-4 0 to 85 C (-40 to 18 5 F )
o o
St orage Temperature
-4 0 to 75 C (-40 to 16 7 F )
o o
Op erating Tempe rature
5% t o 95% Non-c on densingOp erating H umidity
Re gu la to ry Approvals
CI SPR 32, EN5 50 32, FCC Part 15B cla ss AEM I
IE C 61000-4 -2 ( ESD), IEC 6 1000-4- 3 (RS), IEC 6 10 00-4-4 (E FT ), IEC 6100 0-4-5 (Su rge), IEC 6 10 00-4-6 (C S), IEC 610 00-4-8 (P FM F),
IE C 61000-4 -1 1 (DIP)
EM S
IE C60068- 2- 27Sh ock
IE C60068- 2- 32
IE C60068- 2- 6Vi brati on
EN 60950-1 c om pliant
Sa fety
Fr ee Fa ll
Wa rr an ty
5 ye ars
MT BF ( hr s)
722009hrs
DI P Sw it ch
DI P-Swi tc h 1
DI P-Swi tc h 2 Power-1 f ailed war ning : (ON) e nable, (O FF ) disab le
DI P-Swi tc h 3 DIP switc h 3 an d 4 (ON) : SFP sp eed setti ng to 100Mb ps
LE D In di ca tors
Power Ind ic ator (PWR ) Gr een : Pow er L ED x 3
DI P-Swi tc h 4
DI P switch 3 an d 4 (O FF) : SFP spe ed settin g to 1000Mb ps (defa ul t)
Power-2 f ailed war ning : (ON) e nable, (O FF ) disab le
Fault I ndicato r (Fa ul t) Am ber : Indic at e power fai led eve n warning
10 /100/10 00 Base-T(X ) RJ45
Port Indi ca tor
Gr een for por t Li nk/Act.
Du al color LE D fo r speed ind icator ~ Gr een for 100 0Mbps / Amb er f or 100Mbp s / off-l ight for 10 Mbps
10 0/1000B as e-X S FP Port
In dicator G re en for port L ink/Act .
En 55032, EN 55 024(CE EM C), FCC Part 15B, EN 61000-3 -2, EN610 00 -3-3EM C
ORing Industrial Networking Corp.
Copyright© 2017 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com

Other ORiNG Switch manuals

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG IPS-1042FX-24V Series User manual

ORiNG

ORiNG IPS-1042FX-24V Series User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG IGS-9080 User manual

ORiNG

ORiNG IGS-9080 User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG IES-1080A User manual

ORiNG

ORiNG IES-1080A User manual

ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54 User manual

ORiNG

ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54 User manual

ORiNG IES-1050A User manual

ORiNG

ORiNG IES-1050A User manual

ORiNG IES-2050 User manual

ORiNG

ORiNG IES-2050 User manual

ORiNG IGPS-1080-24V User manual

ORiNG

ORiNG IGPS-1080-24V User manual

ORiNG IES-3160 User manual

ORiNG

ORiNG IES-3160 User manual

ORiNG IGPS-9080-24V User manual

ORiNG

ORiNG IGPS-9080-24V User manual

ORiNG Transporter Series User manual

ORiNG

ORiNG Transporter Series User manual

ORiNG TGPS-9084GT-M12X-BP2-24V User manual

ORiNG

ORiNG TGPS-9084GT-M12X-BP2-24V User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG TPS-141TX-M12 Series User manual

ORiNG

ORiNG TPS-141TX-M12 Series User manual

ORiNG IGPS-9084GP-LA User manual

ORiNG

ORiNG IGPS-9084GP-LA User manual

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG IGS-9084GP-LA User manual

ORiNG

ORiNG IGS-9084GP-LA User manual

ORiNG IGS-1050A User manual

ORiNG

ORiNG IGS-1050A User manual

ORiNG TGPS-9164GT-M12X-BP2-24V User manual

ORiNG

ORiNG TGPS-9164GT-M12X-BP2-24V User manual

ORiNG IES-1041FX-MM-SC User manual

ORiNG

ORiNG IES-1041FX-MM-SC User manual

Popular Switch manuals by other brands

Cisco Catalyst 2955 Series Hardware installation guide

Cisco

Cisco Catalyst 2955 Series Hardware installation guide

Cyclades User's Guide user guide

Cyclades

Cyclades User's Guide user guide

Eneo IAR-7SH1024MMA user manual

Eneo

Eneo IAR-7SH1024MMA user manual

Fermax 8944 manual

Fermax

Fermax 8944 manual

MTS Systems ATS-21AG Operator's manual

MTS Systems

MTS Systems ATS-21AG Operator's manual

WOODLAND SCENICS JP5702 manual

WOODLAND SCENICS

WOODLAND SCENICS JP5702 manual

Ruijie Networks RG-S8605E Hardware  installation and reference guide

Ruijie Networks

Ruijie Networks RG-S8605E Hardware installation and reference guide

Edimax HP-5101ES datasheet

Edimax

Edimax HP-5101ES datasheet

Balluff BES M30MF2-PSC15F-BV02-EXD user guide

Balluff

Balluff BES M30MF2-PSC15F-BV02-EXD user guide

Altusen KH-88 Quick start quide

Altusen

Altusen KH-88 Quick start quide

ADC Cuda 12000 installation guide

ADC

ADC Cuda 12000 installation guide

SEIAOTEK ST-G16T user manual

SEIAOTEK

SEIAOTEK ST-G16T user manual

Perle RPS1620 user guide

Perle

Perle RPS1620 user guide

l-com IES Series user guide

l-com

l-com IES Series user guide

Equinox Systems ESP-2 MI installation guide

Equinox Systems

Equinox Systems ESP-2 MI installation guide

LITETRONICS BSC02 user guide

LITETRONICS

LITETRONICS BSC02 user guide

Dell S6000-ON installation guide

Dell

Dell S6000-ON installation guide

Edge-Core AS7712-32X Safety and regulatory information

Edge-Core

Edge-Core AS7712-32X Safety and regulatory information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.