OWL Intuition-lc User manual

© 2 Save Energy Limited 2014 1
Electricity consumption monitoring – three phase
for larger homes and light commercial premises
IN THE BOX:
3 x AA
alkaline battery
Getting started with
Transmitter unit
3 channel
3 x plug-in standard
Sensor clamp
(<10mm cable, <71A)
OR
3 x plug-in large
Sensor clamp
(<17mm cable, <200A)
MADE IN CHINA
MODEL : CMA116
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
x 3

2 © 2 Save Energy Limited 2014
Introduction
This Electricity Transmitter is a part of the OWL Intuition range of cloud connected moni-
toring and control products. Its operation is dependant upon being paired to the broad-
band Internet connected Network OWL (supplied separately).
This version of the Electricity Transmitter is designed for monitoring three phase electric-
ity consumption. It is suitable for use in larger homes and some smaller light commercial
premises.
Access to both live and historic energy information collected by this Transmitter is via the
OWL Intuition web dashboard, from any Internet connected computer anywhere in the
World. iPhone and Android smartphone apps are also available for free download.
For details on using your new OWL Intuition-lc system, please download the Electricity
Monitoring User Manual document by clicking on Manuals on the web dashboard (lower
right).

© 2 Save Energy Limited 2014 3
Installation Instructions
STEP ONE - Install Network OWL
• If you are adding 3 Phase electricity monitoring to an existing Intuition installation
then please jump to STEP THREE - Log in and follow Wizard.
• If this is a new Intuition installation then you will rst need to install the Network OWL
(supplied separately). For full details please refer to the Network OWL installation
guide supplied with that product, however a summary of the steps are listed below:
1. Connect Ethernet cable between spare active LAN port on your broadband Inter-
net router and the Network OWL.
2. Plug the power supply into the mains and insert the DC jack connector into the
base of the Network OWL.
3. Wait until the green LED on the top of the Network OWL is ashing with a “triple
blip” pattern. This should not normally take longer than 2 minutes.
4. Do NOT proceed to STEP TWO until this ashing pattern is observed.
STEP TWO - Create Intuition online account
• If you are adding 3 Phase electricity monitoring to an existing Intuition installation
then please jump to STEP THREE - Log in and follow Wizard.
• If this is a new Intuition installation then you will rst need to create a new OWL

4 © 2 Save Energy Limited 2014
Intuition account. For full details please refer to the Network OWL installation guide
supplied with that product, however a summary of the steps are listed below:
1. Using a web browser visit https://www.owlintuition.com
2. Click “Create Account”.
3. Check and conrm that the Network OWL is online.
4. Fill in the information requested.
5. Click “Create Account” button.
6. Ensure successful account creation completion message is displayed.
STEP THREE - Log in and follow Wizard
• Log in to the OWL Intuition account
with username and password.
• If this is a new system the installa-
tion & conguration Wizard will auto-
matically open. For existing Intuition
installations you should start the
Wizard by clicking the Wizard menu
bar option at the top of the screen.
• Select “Electricity / Solar Monitoring”
from the drop down box.
• Click the “Start” button and follow

© 2 Save Energy Limited 2014 5
the Wizard through these steps:
• Select Electricity Transmitter type as “CMR180i” and
click “Next”.
• Slide back cover off of the Transmitter and insert the
batteries into the unit.
• Press the small “Check” button in the Transmitter bat-
tery compartment until the red LED on the front starts
ashing.
• The Transmitter is now in Pairing / Check Mode and
the red LED on the front will start ashing every 2 sec-
onds (for 30 seconds). Click the Wizard “Next” button.
IMPORTANT Pairing Notes:
• Please DO NOT remove the Transmitter batter-
ies once tted or the pairing will be lost.
• You can quickly check for correct pairing at any time
by pressing the Transmitter “Check” button until the
red LED starts ashing - if the Transmitter red LED and Network OWL blue LED
ash within a fraction of a second of each other, they are correctly paired.
• When the “Pairing Successful” message is displayed in the Wizard click “Next”.
• Select Electricity Monitoring System type as “Intuition-lc (3 phase electricity) and click
“Next”.
PART NO. CMR180i
MADE IN CHINA
PRESS
CHECK BUTTON

6 © 2 Save Energy Limited 2014
• Adjust consumption Voltage and Power Factor settings to measured values if available.
If in doubt leave the default values (Voltage = 230; Power Factor = 1.0) and click
“Next”. Please note that this voltage is the phase to neutral voltage and is hence 230V
rather than 400V (phase to phase voltage).
• Ensure message “Device successfully added to your Intuition system.” is displayed.
• Click the “Finish” button.
• Unless you have further Intuition devices to install / congure then click the “Finish”
button.
• Click the “OK” button to close the Wizard. The web dashboard will then automatically
refresh itself and you should now have an Electricity and a 3 Phase Electricity widget
within the web dashboard, although the live readings will be zero at this stage until
the Sensors are correctly attached in the next step.
STEP FOUR - Install Transmitter and attach Sensors
IMPORTANT:
• You must ensure that each Sensor is ONLY around the live core and NOT around
a sheathed cable containing live, neutral and earth.
• The Sensors must be a loose t onto the cables.
• After the Sensors have been installed, the Transmitter should be hung on the wall
in a free area as far from large metal objects as possible.
• Locate the supply cables between your electricity meter and mains distribution board

© 2 Save Energy Limited 2014 7
(fuse box). See diagram on page 8.
• Using the latch, clamp the 3 Sensors around the insulated Live cables going into the
meter as per the table below – Live cables either side of meter is acceptable.
Phase (Line)
Number
IEC 60446
Wire Colour
Pre 2004
IEE Colour
OWL Transmitter
Socket
1 Brown Red 1 - Left
2 Black Yellow 2 - Centre
3 Grey Blue 3 - Right

8 © 2 Save Energy Limited 2014
Electricity Grid
Fuse Box /
Distribution Board
Industrial
Loads
Ring Mains,
Lights,
Machines
etc
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
Alternative
Sensor
Locations
Utility Meter
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
Transmitter
P1 / L1
Sensor
P2 / L2
Sensor P3 / L3
Sensor
Neutral
Blue
P1 / L1
Brown Black
P2 / L2 P3 / L3
Grey
Intuition-lc
Transmitter & Sensor Installation

© 2 Save Energy Limited 2014 9
STEP FIVE - Log in to your OWL Intuition account
If you are not already, please log in to your OWL Intuition account with your username
and password at: https://www.owlintuition.com
• You should now have an Electricity and 3 Phase widget within your web dashboard.
• If you watch these new widgets, you should see the live total consumption in the Elec-
tricity widget and live individual phase consumption in the 3 Phase widget, updating
every 12 to 60 seconds.
• Check the signal strength of the radio signal between your Transmitter and Network
OWL:
Signal strength indicator Settings icon

10 © 2 Save Energy Limited 2014
• If the signal strength is only 1 or 2 bars, to reduce the chance of intermittent /
inconsistent data reception it is suggested that you reposition the Network OWL
so that it is physically closer to the Transmitter.
• The Network OWL should ideally be hung on the wall in a free area as far from
large metal objects as possible. Position the antenna in a vertical orientation.
• If necessary you can replace the Ethernet cable with a longer cable (up to 100
meters long). If installing a long Ethernet cable is a problem, you can use a
“Powerline Range Extender” or “Wireless Range Extender” - please search for
these common products online.
• For details on using your new OWL Intuition-lc system, please now download the Elec-
tricity Monitoring User Manual document by clicking on Manuals on the web dashboard
(lower right).
• Please ensure you retain this document for future reference.

© 2 Save Energy Limited 2014 11
INFORMATION & TROUBLE SHOOTING TIPS
• Unless the Transmitter is in Check Mode, the red LED does not ash, in order to pro-
long battery life.
• Check that the blue LED on the Network OWL ashes at least every 12 seconds if the
monitored electricity supply consumption is varying, or every 60 seconds when at a
steady state.
• For wireless range testing you can make the Transmitter send its signal every 2 sec-
onds (for 30 seconds) by pressing the “Check” button in the battery compartment for
10 seconds. The red LED will ash with each transmission, the Network OWL blue LED
will ash to conrm the signal has been received.
• If the blue LED does not ash then the Transmitter signal is not being received or the
Transmitter Pairing has been lost.
• On the web dashboard click on the Devices menu, then click on Electricity
Transmitter. If the Last Reported time is greater than 60 seconds then it is likely
the batteries have been removed from the Transmitter since pairing. Click on the
“Change Batteries” button and follow the instructions provided.
• If necessary undo the Transmitter’s Sensors and move it so it is close to the Net-
work OWL. Repeat step above to conrm if radio range is an issue.
• Battery change - when the Transmitter batteries require replacement the battery
icon on the Electricity widget will change to red. Use web dashboard Devices menu /
Electricity Transmitter / Change Batteries feature to ensure that pairing is not lost.

12 © 2 Save Energy Limited 2014
SAFETY INFORMATION
To ensure that you use your product safely and correctly please read the warnings & safety
precautions below before installing your OWL Intuition Transmitter & Sensor.
• This product uses a Type C current Sensor. Do not apply around or remove from haz-
ardous LIVE conductors.
• When tting the Sensor if in any doubt always contact a qualied electrician.
• Do not immerse the unit in water or other liquids. If you spill liquid over it, dry it im-
mediately with a soft cloth.
• Do not use or store the product in conditions that could adversely affect the product
such as rain, snow, desert and magnetic elds.
• Do not subject the product to excessive force, shock, dust, temperature or humidity.
• Keep the product away from heat sources - radiators, stoves, heaters etc.
• Do not use the product in or near water or in high moisture areas such as bathrooms.
• Do not tamper with the product’s internal components. This invalidates the warranty.
• Do not attempt to repair the product yourself.
• Contact the retailer or Customer Services if your product requires servicing.
• If the equipment is used in a manner not specied in this manual, the protection pro-
vided by the equipment may be impaired.
• Take care when handling all battery types. Batteries can cause injuries, burns or dam-
age to property if they come into contact with conducting materials, heat, corrosive

© 2 Save Energy Limited 2014 13
materials or explosives.
• Remove the batteries before storing the product for extended periods.
• Only use fresh batteries. Do not mix new and old batteries.
• Do not dispose of old batteries as unsorted municipal waste, only do so in accordance
with your local waste disposal regulations.
• When disposing of this product do so in accordance with your local waste disposal
regulations.
CARING FOR YOUR PRODUCT
• Before cleaning, disconnect the Sensor and remove the batteries from the Transmitter.
• Use a lightly dampened cloth. Do not use liquid or aerosol cleaning agents, benzene,
thinners, abrasive or corrosive materials.
• Do not scratch hard objects against the product.
• Do not leave discharged batteries in the product.

14 © 2 Save Energy Limited 2014
SPECIFICATIONS
Transmitter dimensions 64mm x 95mm x 40mm
Sensor dimensions (max when closed) 50mm x 50mm x 30mm
Radio frequency band 433MHz unlicenced ISM band
Operating range Up to 30m (in free space)
Power source 3 x 1.5V Alkaline AA batteries
Operating temperature range 0°C to +40°C
Storage temperature range -25°C to +65°C
Relative humidity 25% to 95% non-condensing
COMPLIANCE
The CE marking certies that this product meets the main requirements of the European
Parliament and Council Directive 1999/5/EC. A copy of the signed and dated Declaration of
Conformity is available on request. OWL Intuition products are manufactured to ISO-9001
Quality Assurance Standards.

© 2 Save Energy Limited 2014 15
WARRANTY INFORMATION
2 Save Energy Limited guarantees that OWL Intuition products will work for a minimum
period of 24 months from date of purchase and that it will be free from defects in
materials, workmanship or design. If during this limited 2 year period of guarantee, from
date of purchase, you nd that the equipment is not working properly, you may return it to
us and we will replace, or, (at our discretion) repair it, free of charge.
2 Save Energy Limited will not accept any liability for defects arising from fair wear and
tear, accidental or wilful damage, misuse or failure to follow product or safety instructions
If you return any equipment as faulty, 2 Save Energy Limited reserves the right to test the
equipment and if found to be in perfect working order, to return it to you. In this event, 2
Save Energy Limited reserves the right to charge for any testing or postage costs incurred.
This does not affect your legal rights relating to equipment, which is faulty. Warranty
conditions only apply where Proof of Purchase is provided.
report the issue and your reason for wishing to return your product. 2 Save Energy Limited
will issue you an RMA number. You should ensure that the returned product is clearly
marked with the issued RMA number. Once we have received the product and proof of
purchase we will commence the returns process.

16 © 2 Save Energy Limited 2014
Customer Support
If you have any further questions please check our knowledge base at:
https://theowl.zendesk.com
(please ensure you state your Network OWL MAC ID)
2 Save Energy Limited operate a policy of continuous development and improvement,
therefore the content of this document is subject to change without notice.
Document Version 3.0 - August 2014
For details on using your new OWL Intuition-lc system, please download
the Electricity Monitoring User Manual document by clicking on Manuals on
the web dashboard (lower right).
Other manuals for Intuition-lc
2
Table of contents
Other OWL Measuring Instrument manuals

OWL
OWL FO-4V User manual

OWL
OWL +USB Installation guide

OWL
OWL KIT-WT-D2stKIT-WT-D2sc User manual

OWL
OWL VOLT-1 User manual

OWL
OWL PON-2M User manual

OWL
OWL KIT-Z2-L2 Series User manual

OWL
OWL WT-1 User manual

OWL
OWL OWL+USB Installation guide

OWL
OWL Fiber OWL IIC+ User manual

OWL
OWL OWLTrek WTO-S15 User manual
Popular Measuring Instrument manuals by other brands

Santa Fe
Santa Fe Connect Start here

Sierra
Sierra RedyCompact Series instruction manual

TESTO
TESTO Saveris 2 instruction manual

yellow jacket
yellow jacket YJACK Series quick start guide

Thermo Electron
Thermo Electron ELECTRA Operator's manual

pizzi instruments