Installation Guide
Note to the installer
■ Beforeattemptingtoconnectoroperatethisproduct,pleasereadthelabelontherearof
themainmonitor.
■
Pleasereadthis
guide
carefully,andinstalltheproductsafelyandcorrectlybyfollowing
theinstructions.Carefullyreadtheinformationfoundinthesectiontitled"Foryoursafety"
inparticular.
■
Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
■
Theinstallationshallbecarriedoutinaccordancewithallapplicableinstallationrules.
■
Panasonicassumesnoresponsibilityforinjuriesorpropertydamageresultingfromfailures
arisingoutofimproperinstallationoroperationinconsistentwiththisguide.Additionally,
anyresultingmalfunctionwillnotbecoveredunderthewarranty.
■ Afterinstallation,makesuretoleavethisguidewiththecustomer.
For the Installation of door station
and main monitor station
•VL-V554BXisasurfacemounttype,VL-V554UBX
isaushmounttype.
For your safety
Topreventsevereinjuryandlossoflife/property,readthissectioncarefullybeforeusingthe
producttoensureproperandsafeoperationofyourproduct.
WARNING
Preventingre,electricshockandshortcircuits
● Leaveinstallationworktothedealer.
Installationworkrequirestechniqueandexperiences.Failuretoobservethismay
causere,electricshock,injury,ordamagetotheproduct.Consultthedealer.
● Electricalconnectionworkshouldbeperformedbycertiedpersonnelonly.Certication
isrequiredforperformingelectricalconnectionwork.Consultyourdealer.
● UseonlythespeciedpowersupplyunitandACcable.
● Donotattempttodisassembleor modifythis product.Contact anauthorised service
centreforrepairs.
● Neverinstallwiringduringalightningstorm.
● Donotconnectnon-specieddevices.
● Donotconnectapowercabletoaterminalthatisnotspeciedinthisguide.
● Whenopening holesinwallsfor installation orwiring, orwhen securingthepower
cable,makesureyoudonotdamageexistingwiringandductwork.
● Donotmakeanywiringconnectionswhenthepowersupplyisturnedon.
● Donot usethesuppliedpowersupply unitforoutdoor installations(itis forindooruse
only).
● Donotinstallthemainmonitorandpowersupplyunitinthefollowingplaces:
- Placeswherethemainmonitorandpowersupplyunitmaybesplashedwithwateror
chemicals.
- Placeswherethereisahighconcentrationofdust,orhighhumidity.
● Donot performanyactions(such asfabricating,twisting,stretching, bundling,forcibly
bending,damaging,altering,exposingtoheatsources,orplacingheavyobjectsonthe
powercable)thatmaydamage the power cable. Using the product with adamaged
powercablemaycauseelectricshock,shortcircuits,or fire. Contact an authorised
servicecentreforrepairs.
● W hen e xist ing c hime wire s are u sed, it is poss ible that they cont ain AC v olta ge.
Contactanauthorisedservicecentre.
● Donotinstall oruse theproduct inhealth carefacilities ifany regulationspostedin
the area instruct you not todo so. Hospitals or health care facilities maybe using
equipmentthatcouldbesensitivetoexternalRF(radiofrequency)energy.
● D o not ins tall or us e th is pr oduc t ne ar au toma tic ally cont rol led d evic es s uch a s
automaticdoorsandfirealarms. Radio waves emitted from this product may cause
suchdevicestomalfunction,resultinginanaccident.
Preventingaccidentsandinjuries
CAUTION
● Ifthewiringisunderground,donotmakeanyconnectionsunderground.
● Ifthewiringisunderground,useaprotectiontube.
● Ifthewiringisoutdoors,useaprotectiontubeorasurgeprotector.
● Install theproduct securely adheringto theinstructionsin thisguide to prevent it from
fallingoffthewall.Avoidinstalling onto low-strength walls, such as gypsum board,ALC
(autoclavedlightweightconcrete),concreteblock,orveneer(lessthan18mmthick)walls.
Preventingelectricshock
Preventinginjury
1-62,4-chome,Minoshima,Hakata-ku,Fukuoka812-8531,Japan
©PanasonicSystemNetworksCo.,Ltd.2014
PNQW4430ZA C0814MM0
VL-V554BX/
VL-V554UBX
VL-MWD501BX
Doorstation Mainmonitorstation
Doorstationisdescribedas"doorphone"
andMainmonitorstationisdescribedas
"mainmonitor"inthisguide.
ModelNo. VL-SWD501AZ
VL-SWD501UAZ
Wireless Video Intercom System
Supplied accessories for installation
■ For the doorphone
Mounting
base×1
(AZonly)
Flush
mounting
box×1
(UAZonly)
Screw×4(Usedwhen
installingthedoorphone)
(AZ
:4mmx12mm)
(UAZ:4mmx25mm)
Nameplate×2
(incl.1spare) Hexwrench×1
■ For the main monitor
Mounting
bracket×1 Cablebinder×1 Screw×2
(4mmx16mm)
■ Power supply unit and related items
Powersupply
unit×1
(PartNo.VL-PS241) ACcable×1
Cablebinder×1
Screw×2
(4mmx40mm)
Toavoidmalfunctionorcommunicationdisturbances,donotinstallthedoorphoneorthemain
monitorinthefollowinglocations:
- Placeswherevibrationoranyotherkindofimpactoccurs.
- Placeswhereechoingisfrequent.
- Placesnearahighconcentrationofdust,hydrogensulphide,ammonia,sulphur,ornoxious
fumes.
■
For the doorphone
● Ifastronglightisshining onthedoorphone,the visitor’sfacemaynotbedistinguishable.Do
notplacethedoorphoneinthefollowinglocations:
- Wheremostofthebackgroundisthesky.
- Wherethebackgroundisawhitewall,anddirectsunlightwillreectoffit.
- Wheredirectsunlightwillshineonthedoorphone.
● Donot place thedoorphone in locationswhere echoingoccurs, as thiswill cause the
doorphonetobeepfrequently.
● Dustprotection/waterprotectionisIP54.
Onlywheninstallationworkspeciedinthisguideisproperlyperformedandappropriatewater
protectiontreatmentisperformed.
● Makesuretherearofthedoorphoneisnotsubjecttowater.
● Dependingontheinstallationlocation,condensationmayformonthedoorphone’slenscover.
Thismaycauseimagestobecomeobscured.Condensationwilldissipateasthetemperature
rises.
■
For the main monitor
● Installthe main monitoraway fromelectronic appliancessuch asTVs,radios, personal
computers,airconditioners,boilercontrolpanelswithintercom, home security equipment,
wirelessdevices,ordigitalcordlessphones.
● Donotinstallthemainmonitorinplaceswhereitwillbeaffectedbyextremelyhigh-frequency
radio waves(near broadcasting antennasetc.). Thismay cause thedisplay to icker oran
interruptingnoisetooccur.
● Leaveat least 20cm ofspace above,below, andto theleft and rightsides ofthe main
monitor.Donotinstallonawallthatisdeeplyrecessed.
● Donotinstallthemainmonitorinsideawall.
● Besuretoinstallthemainmonitormorethan5mawayfromthedoorphone.
● Theproduct operates inthe frequency rangeof 1.88 GHzto 1.90 GHz,and the RF
transmission power is 250mW (max.). Refer tothe "For best performance"section in the
OperatingInstructions.
● Inareassurrounded bya highelectrical eld,disturbances mayoccur inthe mainmonitor’s
imageorsound.
Important:
●You will need the following additional items to install and congure the doorphone
and the main monitor.
[Locally procured]
- DCcableandwires(fordoorphoneandotherconnections):
Prepareacableandwiresoftheappropriatespecication.( "Wiretypeandlength")
Note:
● Theillustrationsinthesuppliedmanual(s)mayvaryslightlyfromtheactualproduct.
Precautions for installation
Wiring schematic diagram
Setupcorrectlyaccordingtothefollowingwiringschematicdiagramand"Wiretypeandlength".
●Forinformation,suchasordernumbers,aboutoptionaldevicesthatcanbeconnectedto,refertothe"Additional/replacementaccessories"sectionintheOperatingInstructions.
ブ
プ
MAIN MONITOR
DOORPHONE 1
DOORPHONE 2
POWER SUPPLY UNIT
Connectiondeviceforoptionoutput(Acontact)
NP: Non-polarised
Power
supply
Power
supply
12VAC/DC
12VAC/DC
Electriclock
Electriclock
24VDC
Wire type and length
Wiringrun
Wiretype*1
Diameter Length(Max.)
Mainmonitor–
Doorphone A
ø0.65mm 22AWG 100m
ø1.0mm 18AWG 130m
ø0.5mm CAT5 50m
Mainmonitor–
Powersupplyunit B
ø0.65mm 22AWG 10m
ø1.0mm 18AWG 20m
Doorphone–
Electriclock*2 Cø0.5mm-ø1.2mm
(24AWG-17AWG)
Accordingtospeci-
cationofconnected
device.
Mainmonitor–
Connectiondeviceforoption
output(Acontact)*2
Dø0.5mm-ø1.2mm
(24AWG-17AWG)
Accordingtospeci-
cationofconnected
device.
*1Type:Single-paircablewithoutersheath(jacket)
Conductor:Coppersolid
● Acertiedpowersupplywiringhastobeusedwiththisequipment.Therelevantnational
installationand/orequipmentregulationsshallbeconsidered.Acertiedpowersupplywiring
notlighterthanordinarypolyvinylchlorideexiblewiringaccordingtoIEC60227shallbeused.
*2Whenusinganelectriclockoraconnectiondeviceforoptionoutput(Acontact),selectadevice
thatmeetsthefollowingguidelines:
● Electriclockconnectionterminal(S1/S2):
- N/Odryclosurecontact
- 12VAC/DC,lessthan1A
● Connectiondeviceforoptionoutput(Acontact)terminal(OUT1/OUT2):
- 24VAC/DC,lessthan0.3A(minimumcontact:5VDC1mA)
A
C
C
D
B
NP
NP
NP
NP
NP
NP
&screw×2
(3.8mmx20mm)