Slave/Master Option
Only activate this option with panels featuring more than 12 zones. Only one LCD keypad can be master and all other LCD keypads
are slaves. All slave keypads (LCD and LED) must be used in “mute” mode.
[3] Keypad Code
Use this option to change the Keypad Code (default: 0000). After entering Keypad Programming Mode, select option [3]. Enter the new four-
digit keypad code. During the keypad’s power up, the display reads:
for keypad reset enter and clear.
To set the keypad
code todefault,pressand hold the[ENTER]key.Without releasing the [ENTER]key, press and hold the [CLEAR]key. Hold both keysuntil the display
shows the system status.
[4] Read Key
Use this option to copy the programmed options and labels (messages) from a Paradox Memory Key to the keypad’s memory. Insert a
programmed Paradox Memory Key into the keypad connector labelled “key” (see Figure 1). After entering Keypad Programming Mode, select
option [4]
and then press the [ENTER]key. The display reads:
Reading Key
. The keypad will copy the contents from the key into keypad
memory. This may take approximately 15 seconds. Once the information has been copied, the keypad will emit a confirmation beep.
[5] Write Key
Use this option to copy the programmed options and labels (messages) from a keypad to a Paradox Memory Key. Insert the Paradox Memory
Key into the keypad connector labelled “key” (see Figure 1). Make sure the Memory Key’s jumper is on. After entering Keypad Programming
Mode, select option [5] and then press [ENTER]. The display will read:
Writing Key
. This may take approximately 15 seconds. When the
process is complete, the keypad will emit a confirmation beep. Program one keypad, copy its contents to the memory key as explained in this
option, then program as many keypads as required using option [4] (see above).
[6] Set Time
Use this option to set or change the keypad time. Enter the time using the 24-hour clock (i.e. 4:05pm = [1] [6] [0] [5]).
[7] Set Day
Use this option to set or change the keypad day of week. Use the [
s
][
t
]keys to scroll through the days of the week. Press the [ENTER]key
to save the change.
[8] Set Language
Use this option to set or change the language the keypad will use to display all messages on the LCD screen. The keypad haseight languages
stored in memory. These include: English, French, Spanish, Italian, Polish, Portuguese, Czech, and Slovak. Use the [
s
][
t
]keys to scroll
through the list. Press [ENTER]to save the selection.
[9] Keypad Lock
Use this option to prevent your keypad code from being set to default in the eventof a system shutdown.After selecting option[9], press keys:
[1],[4],[7] to lock your code. Once the keypad code is locked the system will not reset to the default code and the keypad will not display the
message:
For keypad Reset enter and clear
during power up. To unlock, press [0],[0],[0].
Figure 1: Connection Overview
Power Input: Typically 11-16Vdc
Current Consumption: Typically 40mA, Max. 55mA
Tamper Switch: Yes
LCD: Super Twisted Nematic Display (STN),
wide viewing angle, 2 lines of 16 characters,
backlight, and adjustable contrast
Compatibility: All Esprit+ control panels (versions 3.0
onward)
Specifications may change without prior notice.