NV75M-EI00 04/2016
paradox.com
NV75M/MX
Installation Manual V1.0
16 Meter Indoor Dual
Mironel Optics with Anti-Mask
and Pet Immunity Dual Detector
General Description
The NV75M/MX is an indoor industry-leading detector
providing superior 16 meter detection with rock solid stability
thanks to the revolutionary dual Mironel Mirror/Fresnel PIR
optics. Combined with Paradox true Pet Immunity and best-
in-the industry active Anti-Mask technology (EN Grade 3).
The NV75M/MX provides an unmatched high security
solution for any indoor installation.
Installing the NV75M/MX (Fig. 1)
Please Read
Installation Height:
Pet Immune ON - 2.0m/6.6ft to 2.4m/7.8ft
Pet Immune OFF - 2.0m/6.6ft to 2.8m/9ft (lever down)*
*For installations higher than 2.6m, when needed, tilt
the detector down a few degrees for best detection
results; use of a bracket is recommended.
Power Up (30 sec.):
Powering up the detector takes about 30 seconds,
indicated with green/red flashing; indicates PIR
stabilizing.
Anti-Mask Calibration:
Once detector is stabilized, as mentioned above, open
and close the tamper to initiate. Anti-Mask calibration
may take up to 60 seconds. Keep away from the
detector, at least 2 meters / 6 feet during calibration,
indicated by flashing green/red LED. Once completed,
the detector is ready.
Wall Mount
Bracket Mount
Creep Zone/Pet Selection
Remove detector assembly as described in Fig. 1. When
selector is UP, Pet Mode; when DOWN, Creep Zone is
active and there is no Pet Immunity. Above 2.4m Pet
Immune should be OFF (lever down Pet OFF, see
installation height note*.
Dip Switch Settings
Sensitivity Settings
LED Display
Cover Tamper
Step 1 Step 3
NV75MX
NV75M Step 2
TMPCOMALMCOM AM
+
YEL GRN
123 BLK RED
(Table 1)
Table 1
DIP SWITCH OFF ON (DEFAULT)
1. LED OFF ON
2. EDGE DUAL SINGLE
3. PET IMMUNE OFF ON
Feature LED Status Indicator
Tamper open Green: ON for 0.3 seconds every 30
seconds
PIR sensitivity level
setting Green: Flashes 1-5 times according
to the selected level
Alarm detection Red: ON for 3 seconds
Booting/Tamper
close Green/Red alternating flashes
for 45 seconds
Anti-mask detection Flashes orange rapidly (pre-alarm
state) and then constant orange
when in alarm.
Wall Mount x6
Bracket Adjustment
Screw Opening
Corner Mount
x4
Tamper Screw
Wall/Corner
Wiring Entry x2
1
2
345
UP - Pet DOWN - Creep
7m
9m
16m
13m
11m*
NV75M-EI00 04/2016
paradox.com
Programming the NV75MX via Keypad or
BabyWare
Via Keypad
1. Enter EVO Installer Programming Mode, programming
section 4003.
2. Enter the detector’s 8-digit Serial Number. Enter the
3-digit Section as per Table 2.
Table 2
Section [001]:
Section [002]:
Section [003]: 000 (Low) to 004 (Max)
Via BabyWare
1. Double-click the serial number of the NV75MX to open
the detector’s programming.
2. Configure the required settings.
Beam Patterns
Top View
Technical Specifications
Side View
Bit Function Status/Description
[1] LED ON: LED ON (default) OFF: LED OFF
Bit Function Status/Description
[3] Pet
Immune ON:PET ON (default) OFF:Pet OFF
[4] Edge ON:Single (default) OFF:Dual
1.5m 3m 5.5m 10m 16m
(52 ft)
90˚
1.5m3m5.5m 12m10m12m
16m
(52 ft) Creep
Zone
0m 60cm
Creep
Zone
60cm
Specification Description
IR Movement
Detection 2 detectors, 2 dual element sensors,
2 Mironel Optics
Optics Two Mironel Mirror/W Fresnel optics
with mechanical Pet / Creep Zone
Coverage 16 meters/52 feet; 90° - complies
with EN50131-2-2 Grade 3
Anti-Masking Active IR with Dual detectors,
blocking items up to 30cm and lens
applied materials including clear
lacquer; meets and exceeds
EN50131-2-2 Grade 3.
Pet Immunity Pet up to 50cm will not be detected
Single/Dual Edge Infrared detection requires entry or
exit in single-mode; in Dual-edge,
entry and exit is required for both
detectors
Creep Zone Mechanically selectable Creep Zone
detection 1.5m/4ft. (cancels Pet
Immunity when active)
Power - Wired
Models NV75M/NV75MX 23mA
Operating
Temperature -35º to 50º C (-31º to 122º F)
Relative humidity 95% non-condensing
Tamper Dual - Cover and Wall
Dimensions 128 x 62 x 54 mm/ 5.1 x 2.4 x2.1 in
Weight 120 gr/ 0.3 lb
Certifications CE, EN50131-2-2 Grade 3, Class II
10m5.5m3m1.5m
Creep
Zone
16m
(52 ft)
60cm 12m
Detector 1 Detector 2 Both Detectors
2.1m
Optimal
2.8m
2.4m
Pet Immune ON Pet Immune OFF
3m
1
.5
m
Creep
Z
one
60
cm
D
etector
1
D
etector
2.1m
Optimal
2.8m
2.4m
2.1m
2
.8m
2
.
4
m
2.1m
Optimal
2.8m
2.4m
* Read installation height note*
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement is found on the website: www.paradox.com/terms or
contact your local distributor. Specifications may change without prior notice.
Patents
US, Canadian and international patents may apply. Paradox is a trademark or registered trademark of Paradox Security Systems (Bahamas) Ltd.

This manual suits for next models

1

Other Paradox Security Sensor manuals

Paradox NV37MX User manual

Paradox

Paradox NV37MX User manual

Paradox Magellan PMD1P User manual

Paradox

Paradox Magellan PMD1P User manual

Paradox DG85W User manual

Paradox

Paradox DG85W User manual

Paradox PMD2P User manual

Paradox

Paradox PMD2P User manual

Paradox Magellan PMD1P User manual

Paradox

Paradox Magellan PMD1P User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox PRO Plus User manual

Paradox

Paradox PRO Plus User manual

Paradox TM50 Touch User manual

Paradox

Paradox TM50 Touch User manual

Paradox NV500 User manual

Paradox

Paradox NV500 User manual

Paradox Paradome DG467 User manual

Paradox

Paradox Paradome DG467 User manual

Paradox PMD85 User manual

Paradox

Paradox PMD85 User manual

Paradox Magellan MG-PMD1P User manual

Paradox

Paradox Magellan MG-PMD1P User manual

Paradox MAGELLAN MG-PMD75 User manual

Paradox

Paradox MAGELLAN MG-PMD75 User manual

Paradox NV35M User manual

Paradox

Paradox NV35M User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox Magellan PMD75 User manual

Paradox

Paradox Magellan PMD75 User manual

Paradox NV780MX User manual

Paradox

Paradox NV780MX User manual

Paradox Magellan PMD75 User manual

Paradox

Paradox Magellan PMD75 User manual

Paradox SR230 User manual

Paradox

Paradox SR230 User manual

Paradox Omnia OMN-PMD1 User manual

Paradox

Paradox Omnia OMN-PMD1 User manual

Paradox NV37MR User manual

Paradox

Paradox NV37MR User manual

Paradox NVR35M User manual

Paradox

Paradox NVR35M User manual

Paradox NV35MR User manual

Paradox

Paradox NV35MR User manual

Paradox DG457 User manual

Paradox

Paradox DG457 User manual

Popular Security Sensor manuals by other brands

Pyronix KX12DQ-WE quick start guide

Pyronix

Pyronix KX12DQ-WE quick start guide

NAPCO PIR1680 Installation insructions

NAPCO

NAPCO PIR1680 Installation insructions

Aling Conel 72203 installation manual

Aling Conel

Aling Conel 72203 installation manual

schmersal EX-CSS 180 operating instructions

schmersal

schmersal EX-CSS 180 operating instructions

Halma Ampac TITANUS MICRO-SENS Technical manual

Halma

Halma Ampac TITANUS MICRO-SENS Technical manual

D-tect Systems rad-D user manual

D-tect Systems

D-tect Systems rad-D user manual

DeWalt DE0732 instructions

DeWalt

DeWalt DE0732 instructions

APG LPU-2428 user manual

APG

APG LPU-2428 user manual

Honeywell FS24X user manual

Honeywell

Honeywell FS24X user manual

Skil DT0551 Original instructions

Skil

Skil DT0551 Original instructions

Petzl VIZEN manual

Petzl

Petzl VIZEN manual

LinMot DM01-23-FS installation guide

LinMot

LinMot DM01-23-FS installation guide

AVS OUTSPIDER PA manual

AVS

AVS OUTSPIDER PA manual

SILENTRON 5514 SILENT Dual Tech manual

SILENTRON

SILENTRON 5514 SILENT Dual Tech manual

Teletek electronics SensoMAG R20 Installation instruction

Teletek electronics

Teletek electronics SensoMAG R20 Installation instruction

EMX NIR operating instructions

EMX

EMX NIR operating instructions

Kistler 9329A instruction manual

Kistler

Kistler 9329A instruction manual

Pella Insynctive Product guide

Pella

Pella Insynctive Product guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.