1
www.phywe.com, © All rights reserved 12903-00 / 0321
Operating instruc-
tions
Cobra SMARTsense Temperature -40…120 °C
12903-00
PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10
D–37079 Göttingen
Telefon +49 (0) 551 604–0
Fax +49 (0) 551 604–107
E-mail info@phywe.de
Internet www.phywe.com
The unit complies
with the applicable
EC-guidelines
Fig. 1: 12903-00 Cobra SMARTsense Temperature -40…120 °C
TABLE OF CONTENTS
1SAFETY PRECAUTIONS
2PURPOSE AND CHARACTERISTICS
3FUNCTIONAL AND OPERATING ELEMENTS
4NOTES ON OPERATION
5 HANDLING
6TECHNICAL DATA
7SCOPE OF DELIVERY
8ACCESSORIES
9 CONFORMITY
10 DISPOSAL
1 SAFETY PRECAUTIONS
Carefully read these operating instructions completely
before operating this instrument. This is necessary to
avoid damage to it, as well as for user-safety.
Only use the instrument for the purpose for which it was
designed.
Only use the instrument in dry rooms in which there is no
risk of explosion.
Protect the instrument from dust, moisture and vapours.
Use a slightly moist lint-free cloth to clean the instrument.
Do not use aggressive cleaning agents or solvents.
Take care that no liquid penetrates in through the hous-
ing openings, as such penetration would result in dam-
age to Sensor.
Do not open the unit.
2 PURPOSE AND CHARACTERISTICS
The sensor is used for measuring temperature values and for
transferring the values to a terminal device, e.g. a tablet
computer, smartphone, etc., via Bluetooth.
Caution!
2
www.phywe.com, © All rights reserved 12903-00 / 0321
3 FUNCTIONAL AND OPERATING ELEMENTS
3.1 Operating elements
The sensor has an on-button and two LEDs for indicating the
Bluetooth and battery charge status.
On-button
Press the on-button for more than 3 seconds to switch the
sensor on and off
Bluetooth-LED
Flashing red every 2 seconds
Not connected
Flashing green every 2 seconds
Connected to the ter-
minal device
Flashing green every 4 seconds
Running measurement
Battery charge LED
Flashing red every 5 seconds
Low battery
3.2 Functional elements
The temperature-sensitive element is located at the tip of the
15 cm long, corrosion-resistant sensor rod.
4 NOTES ON OPERATION
The device fulfils all of the technical requirements that are
compiled in current EC guidelines. The characteristics of this
product qualify it for the CE mark.
This instrument is only to be put into operation under special-
ist supervision in a controlled electromagnetic environment in
research, educational and training facilities (schools, universi-
ties, institutes and laboratories).
The individual connecting leads are each not to be longer
than 2 m.
The instrument can be so influenced by electrostatic charges
and other electromagnetic phenomena (HF, bursts, indirect
lightning discharges) that it no longer works within the given
specifications. Carry out the following measures to reduce or
eliminate the effect of such disturbance: Ensure potential
equalization at the PC (especially with Laptops). Use screen-
ing. When a total failure of the instrument occurs, unplug it
and plug it back in again for a reset.
5 HANDLING
This section describes the start-up of the sensor and the re-
cording of measurement data. Please read this section thor-
oughly in order to avoid failures or operating errors.
5.1 Start-up
Switch the sensor on by pressing the on-button for more than
3 seconds. The Bluetooth LED lights up red. Start the soft-
ware and select the sensor.
There is a 9-digit code
on the back of the sen-
sor (Fig.2). The last 4
digits of the code corre-
sponds to the last four
digits of the sensor
name in the software
(Fig.3). This allows an
exact assignment of the
sensors with the soft-
ware.
Fig. 2
Fig.3
After the sensor has been selected in measureApp, the LED
flashes green to indicate a correct connection.
If the sensor is switched on and not connected, it switches off
automatically after 5 minutes.
5.2 Recording of temperature measurement data
Hold the sensor into the medium to be measured down to a
maximum depth of 15 cm. Take the response time of the sys-
tem due to the metallic sensor rod into consideration.
5.3 Replacing the battery
Remove the battery
Open the sensor by turning the screw
cap on the back of the sensor counter-
clockwise, e.g. with a coin.
Fig. 4
Lever the battery sensitively,
e.g. with the help of a small
screwdriver or a small pair of
scissors, out of its socket. In-
sert the screwdriver as shown
in Fig. 5.
Fig. 5
Insert new battery
Slide the battery under the golden metal nose (Fig.6-1). Make
sure that the battery is completely under the metal nose and
completely pushed to the upper edge.
Push the battery into the socket
by pressing lightly on the oppo-
site side.
The battery slips under the two
plastic lugs (Fig. 6-2), which is
also noticed by a short "click".
Fig. 6
2
1
3
www.phywe.com, © All rights reserved 12903-00 / 0321
Before closing, make sure that
the seal in the lid is not bent and
lies neatly on the edge of the lid.
Then tighten the cover clock-
wise.
Fig. 7
6 TECHNICAL DATA
Operating temperature range: 5 - 40°C
Rel. humidity < 80%
Sensor sheath
Stainless steel, 5 mm
Measuring range
Absolute accuracy
Resolution
-40...+120°C
± 0.5°C
0.01°C
Max. data transfer rate
Battery type
Max. wireless range (open field)
IP category
Dimensions (width x height x depth)
10 Hz
CR2032
30 m
IP67
230 x 35 x 15 mm
Weight
34 g
7 SCOPE OF DELIVERY
The extent of delivery is as follows
Cobra SMARTsense Temperature 12903-00
Operating instructions
8 ACCESSORIES
Button Cell CR2032, 3V 07922-15
USB-Bluetooth-Adapter 07936-00
Software measureLAB 14580-61
Free measureApp available from supplier portals
iOS
Android
Windows
9 CONFORMITY
10 DISPOSAL
The packaging mainly consists of environmentally-friendly
materials that should be returned to the local recycling sta-
tions.
PHYWE Systeme GmbH & Co. KG
Abteilung Kundendienst
Robert-Bosch-Breite 10
D–37079 Göttingen
Telefon +49 (0) 551 604-274
Fax +49 (0) 551 604-246
Do not dispose of this product with normal
household waste. If this unit needs to be
disposed of, please return it to the address
that is stated below for proper disposal
PHYWE Systeme GmbH & Co.KG hereby
declares that the radio system type 12903-
00 complies with the 2014/53/EU directive.
The complete text of the EC Declaration of
Conformity is available at the following In-
ternet address:
www.phywe.com/en/ec-declaration

Other PHYWE Measuring Instrument manuals

PHYWE Cobra4 Sensor-Unit Tesla User manual

PHYWE

PHYWE Cobra4 Sensor-Unit Tesla User manual

PHYWE Cobra SMARTsense Current User manual

PHYWE

PHYWE Cobra SMARTsense Current User manual

PHYWE 13621.00 User manual

PHYWE

PHYWE 13621.00 User manual

PHYWE 12938-00 User manual

PHYWE

PHYWE 12938-00 User manual

PHYWE Cobra SMARTsense Chloride Ion User manual

PHYWE

PHYWE Cobra SMARTsense Chloride Ion User manual

PHYWE Cobra4 Mobile-Link 2 User manual

PHYWE

PHYWE Cobra4 Mobile-Link 2 User manual

PHYWE Cobra SMARTsense Ammonium Ion 12913-00 User manual

PHYWE

PHYWE Cobra SMARTsense Ammonium Ion 12913-00 User manual

PHYWE Cobra SMARTsense User manual

PHYWE

PHYWE Cobra SMARTsense User manual

PHYWE Cobra SMARTsense User manual

PHYWE

PHYWE Cobra SMARTsense User manual

PHYWE Cobra SMARTlink User manual

PHYWE

PHYWE Cobra SMARTlink User manual

PHYWE 11500.10 User manual

PHYWE

PHYWE 11500.10 User manual

PHYWE Cobra SMARTsense User manual

PHYWE

PHYWE Cobra SMARTsense User manual

PHYWE Cobra4 User manual

PHYWE

PHYWE Cobra4 User manual

PHYWE Cobra SMARTsense User manual

PHYWE

PHYWE Cobra SMARTsense User manual

PHYWE Cobra4 Sensor-Unit Weather User manual

PHYWE

PHYWE Cobra4 Sensor-Unit Weather User manual

PHYWE Timer 2-1 User manual

PHYWE

PHYWE Timer 2-1 User manual

PHYWE Cobra4 User manual

PHYWE

PHYWE Cobra4 User manual

PHYWE Cobra SMARTsense Oxygen User manual

PHYWE

PHYWE Cobra SMARTsense Oxygen User manual

PHYWE Cobra SMARTsense Magnetic field User manual

PHYWE

PHYWE Cobra SMARTsense Magnetic field User manual

PHYWE 13609-99 User manual

PHYWE

PHYWE 13609-99 User manual

PHYWE Cobra4 Sensor-Unit Conductivity+ User manual

PHYWE

PHYWE Cobra4 Sensor-Unit Conductivity+ User manual

PHYWE Cobra4 User manual

PHYWE

PHYWE Cobra4 User manual

PHYWE Cobra SMARTsense Potassium Ion User manual

PHYWE

PHYWE Cobra SMARTsense Potassium Ion User manual

PHYWE Cobra SMARTsense Radioactivity 12937-01 User manual

PHYWE

PHYWE Cobra SMARTsense Radioactivity 12937-01 User manual

Popular Measuring Instrument manuals by other brands

Gamatronic GMAC-5 user guide

Gamatronic

Gamatronic GMAC-5 user guide

palintest Lumiso Ammonia user manual

palintest

palintest Lumiso Ammonia user manual

CEM ORACLE manual

CEM

CEM ORACLE manual

Endress+Hauser Stamolys CA71SI Series operating instructions

Endress+Hauser

Endress+Hauser Stamolys CA71SI Series operating instructions

ECTIVE BM X operating instructions

ECTIVE

ECTIVE BM X operating instructions

Thermometer 8000 operating instructions

Thermometer

Thermometer 8000 operating instructions

EMIS EMIS-VIHR 200 Operation manual

EMIS

EMIS EMIS-VIHR 200 Operation manual

RKI Instruments GX-6000 Operator's manual

RKI Instruments

RKI Instruments GX-6000 Operator's manual

WATANABE ELECTRIC INDUSTRY CO., LTD AP-101-11 instruction manual

WATANABE ELECTRIC INDUSTRY CO., LTD

WATANABE ELECTRIC INDUSTRY CO., LTD AP-101-11 instruction manual

Fraba TILTIX MEMS AKS user manual

Fraba

Fraba TILTIX MEMS AKS user manual

Stahl 8405/6 Series operating instructions

Stahl

Stahl 8405/6 Series operating instructions

VOLTCRAFT LCR-300 operating instructions

VOLTCRAFT

VOLTCRAFT LCR-300 operating instructions

DMO Wirewalker user guide

DMO

DMO Wirewalker user guide

Anritsu VNA Master MS2024B Maintenance manual

Anritsu

Anritsu VNA Master MS2024B Maintenance manual

Ambient Weather PM2.5IN user manual

Ambient Weather

Ambient Weather PM2.5IN user manual

Dräger Interlock 7000 Instructions for use

Dräger

Dräger Interlock 7000 Instructions for use

Lasertec HV1G instruction manual

Lasertec

Lasertec HV1G instruction manual

Siemens SITRANS FP 7ME17.8 operating instructions

Siemens

Siemens SITRANS FP 7ME17.8 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.