OPERATING AND INSTALLATION INSTRUCTIONS SYSTEM VENTECH LG 500 PAGE 10
Operation of the ventilation unit
is only permitted if all required
connections in conjunction with
the provided installed compo-
nents, such as sound absorbers etc.,
have been properly established.
Upon the occurrence of any defects or
damage that are able to injure people or
damage property, the system has to be
put out of operation immediately. Further
operation must be eectively prevented
until the device is completely repaired!
Where fault messages or damage
occur, the device must be immediately
switched o and disconnected from the
mains.
When opening the front covers or
removing cover plates, act in a safety-
conscious manner and be aware of
the risks. Every working method that
impairs safety is prohibited. Operation
of the device is only permitted with a
connected air line or installed system
components, such as sound absorbers,
with a minimum line length of 1000 mm
to ensure that the fans or electrical com-
ponents, for example, cannot be touched
by hand.
The ventilation unit must be operated
only in compliance with the project
documents. These must comply with the
equipment and product safety act and
with the relevant applicable stipulations
of the EC directives and standards.
Never operate the ventilation unit wit-
hout installed air filters. The air filters
must be checked regularly for conta-
mination and damage and cleaned or
replaced if necessary.
The air filters are to be replaced at least
every six months or when the „filter
change“ message appears on the control
unit. Use only genuine spare filters. If
the system is not in operation in the
summer, for hygienic reasons the air
filters have to be replaced before putting
it back into operation.
In case of simultaneous use of the ven-
tilation unit with fireplaces consuming
indoor air, the applicable safety instruc-
tions and standards must be observed.
In the case of indoor air dependent
fireplaces the combustion air supply has
to be provided separately. Advice on this
is provided under point 2.1.2 „Provisions
for operation with fireplaces“.
Owing to their heavy loading and irre-
gular operation, extractor hoods must
not be integrated into the extract air or
exhaust air circuit of the ventilation unit.
Advice on this is provided under point
2.1.3 „Provisions for use with extractor
hoods „. Exhaust air extractor hoods
must be operated via separate air lines,
with provision for a suitable fresh air
supply, e.g. by opening windows, or via
suitable air filters in recirculated air
mode.
3.2.4 Operation of the system
4 Functioning of the ventilation system
In the case of mechanically controlled
apartment ventilation the consumed,
humid extract air from the wet rooms of
the apartment, e.g. bathroom, toilet and
kitchen, is discharged and replaced by
conditioned, fresh and filtered outdoor
air in the residential areas such as the
lounge, bedrooms and other living areas.
High energy savings in the operation
of the ventilation unit can be realised
through needs-based system opera-
tion, the use of a highly ecient heat
exchanger for the recovery of heat from
the extract air into the supply air and
the use of energy-ecient fans with the
latest EC technology.
It should be particularly ensured that
the highly ecient heat exchanger is
protected against freezing via a suitable,
controlled frost-protection strategy and
that an eective condensate water out-
let, among other measures, is in place.
The more airtight the building shell and
the more eectively a house is insulated,
the more eective this technology is.
4.1 SYSTEM DESCRIPTION