Page 1.2 30A SOLID STATE MATRIX MODULE 40-555B
pickering
SECTION 1 - TECHNICAL SPECIFICATION
PXI & CompactPCI Compliance
The module is compliant with the PXI Specification 2.2. Local
Bus, Trigger Bus & Star Trigger are not implemented.
Uses a 33 MHz 32-bit backplane interface.
Safety & CE Compliance
All modules are fully CE compliant and meet applicable
EU directives:
Low-voltage safety EN61010-1:2010,
EMC Immunity EN61326-1:2013,
Emissions EN55011:2009+A1:2010.
Operating/Storage Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 90 % non-condensing
5000 m
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 90 % non-condensing
15000 m
Mechanical Characteristics
Double slot 3U PXI (CompactPCI card).
3D models for all versions in a variety of popular file formats
are available on request.
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Signals via 2 front panel 8-pin male power D-Type connectors,
for pin outs please refer to the operating manual.
Interlock via 4-pin female 00 series connector*
(40-555B versions with hardware interlock option)
*Mating half supplied when hardware interlock option
ordered, to be wired by end user.
Switching Specification
Switch Type: Solid State MOSFET
Max Switch Voltage:
Continuous Crosspoint
Current:
Peak Current:
±40 V* (DC or AC peak)†
30 A continuous ‡,
40 A continuous with single
relay per module closed
120 A for 200 µs
Max Y-Bus Current: 40 A
Path Resistance - On:
Leakage Current (at ±40 V):
6 mΩ at 25 ˚C typical
<1 µA at 25 ˚C and switch
cold, <5 mA at max
temperature immediately
after switch has carried
maximum current for >10
minutes.
Rise/Fall Time:
Operate Time:
Max Operating Speed at
nominal load:
8 µs (typical)
250 µs
60 operations/sec
Expected Life (operations): Indefinite when used
within ratings
* For full voltage rating, signal sources to be switched must
be fully isolated from mains supply and safety earth.
† Differential voltage between channels must not exceed
rated voltage, additional caution should be used when
applying AC voltages as multiple asynchronous supplies can
create high differential voltages between channels.
‡ The capacity of the module to carry 30 A on all channels
is chassis dependent and dependent on the number of high
power modules fitted to the chassis. Specification reflects test
conditions in a Pickering PXI chassis. Refer to supplier for
chassis cooling capacity, restrict average RMS current over
5 minute period to 25 A per channel for chassis meeting the
minimum PXI recommendations.
Power Requirements
+3.3 V +5 V +12 V -12 V
100 mA 1400 mA 0 0
40-555B
pickeringtest.com Page 2
Specifications