LXI 1GHz RF MATRIX 60-732
pickering SECTION 1 - TECHNICAL SPECIFICATION
LXI 1GHz Matrix, 60-732
pickeringtest.com
Specifications
General Matrix Information
Matrix Size: 32x4, 24x4, 16x4 or 8x4
Connectors: Front panel Precision
F-type.
Operating Time: 3 ms
Max. DC Switch Voltage: 6 V
Max. DC Current: 0.08 A
Max Power Rating: 0.48 W per path
Life Expectancy: 107 operations at <100 mW
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 85 % non-condensing
5000 m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 85 % non-condensing
15000 m
Safety & CE Compliance
All products are fully CE compliant and meet applicable EU
directives:
Low-voltage safety EN61010-1:2010,
EMC Immunity EN61326-1:2013,
Emissions EN55011:2009+A1:2010.
Mechanical Characteristics
Supplied with front panel ears to enable rack mounting on a
shelf or other rear support mechanism.
Dimensions:
32x4 & 24x4 Versions: 3U high, full 19” rack width,
500
mm depth
16x4 & 8x4 Versions: 2U high, full 19” rack width,
500
mm depth
3D models for all versions in a variety of popular file
formats are available on request.
Connectors
Signals via front panel F-type connectors.
LAN Interface
Compliant to LXI Standard 1.4, the 60-732 has a
1000Base-T Ethernet Interface via a standard RJ-45
connector mounted on the rear panel with an LCD display
showing the unit’s IP address*.
*Note: Legacy units may not have 1000Base-T support or
be fitted with an LCD display.
Matrix RF Specification
Characteristic Impedance: 75 Ω
Usable Frequency Range: DC to 1.5 GHz
Insertion Loss (typical): -0.3 dB at 100 kHz
-1.7 dB at 900 MHz
-2.5 dB at 1.5 GHz
VSWR (typical)
Internal termination:
Thru path:
1.4:1 at 900 MHz
1.8:1 at 1.5 GHz
1.6:1 at 900 MHz
1.8:1 at 1.5 GHz
Isolation (typical):
Single X to Y path: -85 dB at 900 MHz
-80 dB at 1.5 GHz
Crosstalk
Typical:
Other paths:
-75 dB at 900 MHz
-65 dB at 1.5 GHz
-75 dB at 900 MHz
-70 dB at 1.5 GHz
Maximum RF Power: 0.125 W
(limited by termination
resistors)
LXI Status Indicators
Front panel mounted LEDs:
• Power
• Ready
• Error
• LAN
• Active
Power Source
Universal AC mains supply, 90-120/200-240 V 50-60 Hz
Power Inlet: Male IEC connector
Power Rating: 100 VA maximum
Fuse Rating: 2.5 A, 250 V