Page 1.3
LXI HIGH DENSITY EMR MATRIX 60-550/551
pickering SECTION 1 - TECHNICAL SPECIFICATION
LXI High Density 512x8 EMR Matrix – 60-550/551
pickeringtest.com
Specifications
Switching Specification
Switch Type Electro-mechanical
Contact Type: Palladium-Ruthenium, Gold
Covered Bifurcated
Max Switch Voltage: 300VDC/250VAC*
Max Power:
Max Switch Current:
Max Continuous Carry Current:
Max Pulsed Carry Current
Example (for a single switch path):
62.5VA, 60W from 30V to
220VDC, 30W to 300VDC
(resistive load)
2A
2A
6A for 100ms
(up to 10% duty cycle)
Initial Path Resistance - On:
Initial Path Resistance - Off:
Minimum Voltage:
Thermal Offset:
<1Ω (X to X)†
>109Ω
100µV
<5µV
Operate Times
Crosspoint Relay:
Crosspoint + Isolation Relay:
3ms
6ms
Expected Life (operations)
Very low power signal load:
Low power load (2W):
Medium power load (30W):
Full power load (60W):
>1x108
>1.5x107 (0.1A 20VDC)
>5x106 (1A 30VDC)
>1x105 (2A 30VDC)
>1x105 (0.1A 300VDC)
Bandwidth: 5MHz typical
(fully populated)
Max Number of simultaneously
closed crosspoints:
526 (BIRST versions)
100†† (non BIRST versions)
* For full voltage rating, signal sources to be switched must be fully
isolated from mains supply and safety earth.
† Path resistance is dependent upon the signal route selected.
†† Higher closure counts are possible, please contact sales ofce
for further information.
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0°C to +55°C
Up to 90% non-condensing
5000m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20°C to +75°C
Up to 90% non-condensing
15000m
Safety & CE Compliance
All products are fully CE compliant and meet applicable EU
directives: Low-voltage safety EN61010-1:2010, EMC Immunity
EN61326-1:2013, Emissions EN55011:2009+A1:2010.
400Hz Operation
For applications requiring the operation of the unit from a 400Hz
supply, for example aircraft or marine supplies, an alternative PSU
build is available. Please contact your local sales ofce for details.
Mechanical Characteristics
Supplied with front panel ears to enable rack mounting on a shelf or
other rear support mechanism.
Dimensions: 1U high, full rack width, 500mm depth
3D models for all versions in a variety of popular le formats are
available on request.
Connectors
Signals via front panel connectors.
X and Y connections are via 8 x 78-pin male D-types.
(Y connections are on the rst two X signal connectors).
For pin outs please refer to the operating manual.
Relay Type
The 60-550/551 is tted with high quality electro-mechanical
relays. These relays are leaded types (not surface mount) so eld
maintenance is greatly simplied. Spare relays are built onto the
circuit board to allow easy maintenance with minimum downtime.
Power Source
Universal AC mains supply, 90-120/200-240V 50-60Hz
Power Inlet: Male IEC connector
Power Rating: 100VA maximum
Fuse Rating: (F) 5A, 250V
LAN Interface
Compliant to LXI Standard 1.4, the 60-550/551 has a 1000Base-T
Ethernet Interface via a standard RJ-45 connector mounted on the
rear panel with an LCD display showing the unit’s IP address.*
*Note: Legacy units may not have 1000Base-T support or be tted
with an LCD display.