Page 1.5
LXI 2.4GHz MATRIX 60-771
pickering SECTION 1 - TECHNICAL SPECIFICATION
LXI 2.4 GHz Matrix, 60-771
pickeringtest.com
Specifications
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 90 % non-condensing
5000 m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 90 % non-condensing
15000 m
Safety & CE Compliance
All products are fully CE compliant and meet applicable
EU directives: Low-voltage safety EN61010-1:2010,
EMC Immunity EN61326-1:2013,
Emissions EN55011:2009+A1:2010.
Mechanical Characteristics
Supplied with front panel ears to enable rack mounting on a
shelf or other rear support mechanism.
Dimensions: 3U high, full 19” rack width, 500 mm depth
3D models for all versions in a variety of popular file
formats are available on request.
Connectors
Signals via front panel SMA connectors.
LAN Interface
Compliant to LXI Standard 1.4, the 60-771 has a
1000Base-T Ethernet Interface via a standard RJ-45
connector mounted on the rear panel with an LCD display
showing the unit’s IP address*.
*Note: Legacy units may not have 1000Base-T support or
be fitted with an LCD display.
General Matrix Information
Matrix Size: 32x8, 24x8, 16x8 or 8x8
Connectors: Front panel SMA
Operating Time: 3 ms
Max. DC Switch Voltage: 5 V
Max. DC Current: 0.1 A
Max Power Rating: 0.5 W per path
Life Expectancy: 106 operations at
<100 mW
Matrix RF Specification
Characteristic Impedance: 50 Ω
Usable Frequency Range: DC to 2.4 GHz
Insertion Loss
X to Y Switch Path:
Y to Y Loop-Thru:
-2.5 dB (typical)
-1.3 dB (typical)
VSWR
X to Y / Y to X Switch Path:
Y to Y Loop-Thru:
Internally Terminated:
1.6:1 (typical) to 2.2 GHz
2:1 (typical) 2.2-2.4 GHz
1.4:1 (typical)
1.6:1 (typical)
Crosstalk: -60 dB (typical)
Isolation
X to Y:
X-channel to X channel:
Y-channel to Y channel:
Y to Y Loop-Thru:
-75 dB (typical)
-60 dB (typical)
-70 dB (typical)
-60 dB (typical)
Maximum RF Power: 0.5 W (limited by
termination resistors)
Power Source
Universal AC mains supply, 90-120/200-240 V 50-60 Hz
Power Inlet: Male IEC connector
Power Rating: 100 VA maximum
Fuse Rating: (F) 5 A, 250 V
LXI Status Indicators
Front panel mounted LEDs:
• Power
• Ready
• Error
• LAN
• Active