pickering
LXI Switch & Instrumentation
Pickering Interfaces www.pickeringtest.com
Product Order Codes
Single 24 x 8 Video Matrix 60-710-711
Dual 24 x 8 Video Matrix 60-710-721
Mating Connectors & Cabling
Please refer to the Pickering Interfaces “Interconnection
Solutions” catalog for a full list of connector/cabling
options, including drawings, photos and specifications.
This is available in either print or as a download.
Latest Details
Please refer to our Web Site for Latest Product Details.
www.pickeringtest.com
LAN Interface
The 60-710 has a 100 Base T Ethernet Interface with a
standard RJ-45 connector mounted on the rear panel.
Programming
All LXI cards are supplied with built-in software drivers (as
per the LXI specification):-
• Windows DLL (similar to Pickering PXI and PCI cards)
• Web Pages for configuration and soft front panel.
Up to date driver software is available from our web site at
www.pickeringtest.com
General Matrix Switching Specification
Maximum Voltage:
Maximum Power:
Maximum Switch Current:
100V DC
60W
1.4A
Characteristic Impedance: 75Ω
On Path Resistance:
Off Path Resistance
Thermal Offset:
<1Ω
>108Ω
<50µV
Expected Life (Low Power):
Expected Life (Max Power):
108 operations
>107 operations
Operate Time: <3ms
RF Specification - Single or Dual 24 x 8 Configuration
Insertion Loss: <0.3dB @ 10MHz, 0.12dB typical
<0.75dB @ 25MHz, 0.29dB typical
typical worst case 0.53dB @ 25MHz
VSWR: <1.4 @ 10MHz, 1.2 typical
<2.0 @ 25MHz, 1.37 typical
typical worst case 1.76 @ 25MHz
Crosstalk: Better than 55dB @ 10MHz
Better than 50dB @ 25MHz
Isolation: Better than 55dB to 25MHz
RF Specification - Single 48 x 8 Configuration
Insertion Loss: <0.3dB @ 10MHz, 0.2dB typical
<1dB @ 25MHz, 0.45dB typical
typical worst case 0.74dB @ 25MHz
VSWR: <1.4 @ 10MHz, 1.2 typical
<2.1 @ 25MHz, 1.45 typical
typical worst case 1.9 @ 25MHz
Crosstalk: Better than 60dB @ 10MHz
Better than 50dB @ 25MHz
Isolation: Better than 70dB to 25MHz
Note: Matrix RF Performance is entirely dependant upon the
combination of crosspoints currently selected, these figures are for
one selected crosspoint on any X or Y channel only, refer to graphs.
For further assistance on getting maximum performance using the
60-710 please refer to the Operating Manual.
Mechanical Characteristics
Supplied configured ready for rack mounting,.
Dimensions: 1U high, full rack width, 340mm depth.
Weight: 4.6Kg
Matrix Signal Connectors: 50Ω SMB
Power Source:
Universal AC mains supply, 90-120/200-240V 50-60Hz
Power inlet: Male IEC connector
Power Rating: 100VA maximum
Fuse Rating: 2.5A 250V
Safety & CE Compliance
All modules are fully CE compliant and meet applicable EU
directives: Low-voltage safety EN61010-1:2001,
EMC Immunity EN61000-6-1:2001, Emissions EN55011:1998.
Relay Type & Maintenance
The 60-710 is fitted with electromechanical signal relays
with palladium-ruthenium, gold covered contacts. These
are leaded relays (not SMT relays) so field maintenance is
greatly simplified. In addition a total of 8 Spare Relays are
fitted to the circuit boards to facilitate easy maintenance with
minimum downtime.
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0°C to 55°C
Up to 90% non-condensing
5000m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20°C to +75°C
Up to 90% non-condensing
15000m
For New Designs Use 60-711
LXI is the new standard
for Ethernet control of
instrumentation. It is the
natural successor to GPIB
(IEEE-488) incorporating
LAN connectivity, full web
browser support, IVI drivers
and advanced triggering
capability.
Pickering Interfaces is a
Board level member of the
LXI Consortium (www.lxistandard.org) and together
with Agilent Technologies was the first company
to release a fully compliant LXI device. Pickering is
developing a large range of products conforming to
the LXI standard and is constantly introducing new
products in response to specific user demand. For
further information go to
www.pickeringtest.com/lxi