pickeringtest.com
LXI Modular 2A Matrix 65-219
ISSUE 2.2 MAY 2020
• Modular Matrix Design with
Y Matrix Sizes of 20 or 40
• Loop-Thru Connections for
Easy Expansion
• Maximum Switch Current of 2A
• Switch up to 220VDC/125VAC
and up to 60W Max Power
• User Configurable for X Dimensions by
Plugin addition
• Fully Compliant to 1.4 LXI Standard
• 3 Year Warranty
Simplified Diagram For 65-219 Configured as a 40x20 Matrix
YA1
YA2
YA3
YA20
X39
X37
X40
X38
X8
X7
X6
X1
X3
X2
X4
X5
1-Pole
Crosspoint
YA19
1-Pole
Isolation
1-Pole
Isolation
YB1
YB2
YB3
YB20
YB19
XLT39
XLT37
XLT40
XLT38
XLT8
XLT7
XLT6
XLT1
XLT3
XLT2
XLT4
XLT5
YC1
YC2
YC3
YC20
YC19
YD1
YD2
YD3
YD20
YD19
The 65-219 is a modular matrix platform designed to provide a
large matrix solution with 2A current carrying capacity on all Y
paths.
Matrices are created by populating the 65-200 chassis with plugin
modules with access to the X axis on 15-pin D-type connectors
and the Y axis on 50-pin D-type connectors. The chassis is
capable of supporting matrices with a Y axis size of 20 or 40 and X
axis sizes up to 60 in increments of 10. Users can specify as many
or as few plugin modules as they require and can eld upgrade the
chassis to extend the matrix.
The chassis supports up to 6 plugin modules. These plugins can
be X or Y types:
The X type plugins have a 10(X)x40(Y) or 10(X)x20(Y) matrix
with connections on a 15-pin D-type plug. Isolation relays
are included to minimize capacitance loading and maximize
bandwidth. A second 15-pin D-type plug is provided for loop-
thru connections.
The Y type plugins have two 50-pin D-type plugs, each
providing connection to the Y-Bus via isolation relays. These
connections provide access for both Y and Y Loop-thru allowing
easy expansion of the system. The chassis can have none
of these plugin modules (no direct Y access), 1 or more – the
latter providing a simple means of adding Switched Signal
connections for additional measurement equipment.
Cooling for the chassis is provided by rear fans and front air
intakes ensuring no wasted space when it is rack mounted. The
cooling system is adaptive, minimizing acoustic noise when used
in quiet laboratory environments. Unused chassis slots are lled
using supplied blanking pieces to ensure correct air ow.
Plugins are loaded into the chassis via the front panel, greatly
improving the exibility and ease of maintenance of the unit.
Configuring the Matrix
To select the parts that you need to create a matrix simply:
• Specify a 65-200-001 Modular Matrix Chassis.
• Add 65-219-10x Y Plugin Modules as required.
• Add 65-219-20x X1 to X10 Plugin Modules needed to make up
the X dimension of the matrix – simply divide the X size by 10
and round up to the next integer to nd the number required.