Puredry PD 2419 Sophia User manual

• USER’S MANUAL
• ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ
ENGLISH | ΕΛΛΗΝΙΚΑ
DEHUMIDIFIER PD 2419 Sophia

LANGUAGES
ENGLISH .............................................................................................................. 3
ΕΛΛΗΝΙΚΑ ..........................................................................................................25

3
TABLE OF CONTENTS
1. SAFETY & WARNING INSTRUCTIONS ............................................................................ 4
2. ELECTRICAL INFORMATION .......................................................................................... 5
3. SOCIABLE REMARKS - ENVIRONMENTAL PROTECTION .............................................. 5
4. NOTES BEFORE OPETATION........................................................................................... 6
6.GETTING TO KNOW YOUR DEHUMIDIFIER ................................................................. 10
7.
CONTROL PANEL FUNCTIONS...................................................................................13
CONTROL PANEL • INDICATORS ................................................................................. 11
9.WATER TANK & DRAIN HOSE ....................................................................................... 15
11.
10.STORAGE ....................................................................................................................... 16
12. FREQUENTLY ASKED QUESTIONS & TROUBLESHOOTING ....................................... 18
Dear Consumer,
Please refer to this manual, to obtain full eiffciency of
the dehumidifier, through the guidelines included in the
following pages and make savings via clever use of this
device.
5. DEHUMIDIFIER SPECIFICATIONS................................................................................... 9
8.
EN
4.1PRESENTATION ........................................................................................................ 7
MAINTENANCE & CLEANING .......................................................................................17
13. WARRANTY TERMS........................................................................................................ 21
Puredry's Sophia PD2419 dehumidifier is distinguished
among its class, by its excellent perfomance, quiet
operation and double air inlets, which guarantee
efficiency regarding humidity issues.
Congratulations on your choice!

!
1. SAFETY & WARNING INSTRUCTIONS
l No children under the age of 8 should be permitted to operate this electric device. Be
certain, that children, handicapped people, or people with the lack of knowledge and
experience, must be supervised, depending the situation, by persons responsible for
their well-being and do not undertake procedures such as the cleaning or the
maintenance of this device.
l It is important that adequate supervision is provided and no minors are left
unattended with this device.
l This dehumidifier is for domestic and small oiffce use only. Do not use this device for
commercial, industrial or marine use, and in areas with wet surfaces such as restrooms or
shower rooms.
l This device should always be kept in an upright position to avoid any damage.
All house exits (windows doors etc) where the dehumidifier is operationg should be
closed.
If water leakage appears within the unit, turn thr unit off and disconnect the power
cord.
Befoe moving, unplug the device and manage to keep it in a vartical position in order to
safely be transferred from one area to another.
Be sure to empty the water whenever the water tank is full or when the device will not
be used for a prolonged time.
Always empty the water tank before storing the unit.
When the unit has been switched off and instantly switched on, keep in mind that, for
operational reasons, there is a 3 minute delay in order ro regain normal operation.
If the unit is misplaced or tipped, unplug the power cord immediately. Make sure the
unit is completely dry bedore resuming operation.
Disconnect the devide, in unnormal sounds, odors or smoke occur.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons to avoid a hazard. Never attempt to dismantle, repair, or
modify the device.
Do not attempt to repair, dismantle or modify this appliance, Contact your authorized
service technician for repair or maintenance of this device.
Do not operate or stop the unit by switching the power supplt on or off.
Do not insert any objects in the unit's air inlet and exhaust as this may cause damage to
the device.
Do not place heavy objects on the power cord. Make sure that the cord is not
compressed.
Do not place cord under any obstacles (carpets rugs ir runners etc). Cord should be
arranged awat from areas where accidental tripping may occur.
Casters should be able to move comfortably over the obstacle. Be extra cautious while
moving over carpets, since any extra force may cause the tipping of the unit, or the spilling
of any water collected in the bucket.
Do not sit or climb on the device
Do not place the unit in direct sunlight or near other heating devices.
Do not use the unit near heat sources, chemicals, radiators or else.
Do not remove water tank while the device is in use.
Do not use the device without the air filter. Dirt and lint may clog the unit thus reducing
it's performance.
Do not drink or use the collected water of the unit for any purpose.
Do not use the unit with wet hands.
4EN

5
2. ELECTRICAL INFORMATION
The nameplate, with all the electrical and technical data of this appliance, is located on the
rear panel.
l The appliance should be installed in accordance with national wiring regulations.
l Be sure the device is grounded properly. Proper grounding is important as it minimizes
the chance of electric shock or fire. The power cord is equipped with a grounding
plug for protection against electric shock hazards.
l The device must be used in a properly grounded wall socket. If the specific socket you
intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker,
have a qualiifed electrician install the proper receptacle.
l Ensure the wall socket is still accessible after the installation of the dehumidifier.
l Do not use extension cords or adapter plugs with this device.
l To avoid personal injury, always disconnect the power supply of the device, before
maintenance.
l The unit’s circuit board (PCB) has an included safety fuse for overcurrent protection. You
may find the specifcations of the fuse, marked on the circuit board, for example: T 3.15A/250V
(or 350V), etc.
Power off the dehumidifier before removing the plug.
3. SOCIABLE REMARKS
ENVIRONMENTAL PROTECTION
Disposal of equipment no longer used:
Please follow the instructions below, when using this dehumidiifer in European countries.
l This appliance requires special treatment for disposal. In the European Union, electronic
equipment must not be treated as domestic waste, but must be disposed of professionally
in accordance with Directive 2002/96/EC of the European Parliament and Council of 27th
January 2003 concerning old electrical and electronic equipment.
The disposal of this unit should follow all legal requirements and should not be disposed
as unsorted municipal waste.
The hazardous substances can leak into the ground water supply thus entering the food
chain, endangering your health and the environment.
l Fluorinated Greenhouse Gasses are contained in hermetically sealed equipment. For
speciifc information regarding the type the amount and the CO2 equivalent in tons, please
refer to the relevant labels of the unit.
l There are several alternative solutions for disposal:
A) Your local municipality has established free collection systems for electronic
waste.
B) Your local retailer upon purchase of a new product.
C) The manufacturer may accept the old appliance for disposal.
D) Old appliances sometimes contain valuable resources for scrap metal dealer..
EN
To connect or disconnect the device hold ith one hand the socket and pull ith the
other.

Model PD 2419 Sophia
Do not remove the device from the plug
while operating. Also do not pull the plug
from the cable.
4.NOTES BEFORE OPERATION
Before cleaning, please make sure that the
dehumidifier is unplugged.
Avoid any contact with the device if you
have wet hands.
Please be sure that the plug that you put
the device is grounded.
Keep the air inlet and outlet unblocked.
Do not put anything on the product. Also
please do not sit or stand on the product.
Do not put the device close to flammable
materilas or in flammable areas.
If you have any questions or you believe
something is wrong please contact with
the manufacture company.
EN
6

EN 7
Continous
Drainage
For warranty purposes, please
note the SN (serial number). The
SN is labeled on side of the device.
Please refer to the electronic
warranty instructions,
in the last page (English
section) of this manual.
Instruction Manual
Compressor
Dedumidifier
4.2 PRESENTATION
Color box

Installation tips
2) Place the unit in an area
where the temperature
levels will not fall bellow 5ºC
(41ºF) There is a possibility
the coils will collect frost at
temperatures that are under
5ºC (41ºF), which may result
in low performance.
3) Ensure the pre filter is clean. Place in right
position the HEPA&Carbon filter.
1) Do not block or restrict
the airlfow around the unit. Make
sure the air inlet exhaust grills are
not obstructed. Allow 20cm of
clearance around the unit and
40cm above.
4)) Place unit in vertical operating position
and allow 2 hours before initial use in
order to avoid malfunctions.
5)
)Before the initial operation, please
check, if the water level switch,
located within the water bucket
area, is in the right position.
EN
8

5. DEHUMIDIFIER SPECIFICATIONS
Model PD 2419 Sophia
Dehumidification Capacity (Liters/24 Hours) *24
Voltage/ Frequency (V/Hz) 220~240 / 50
Consumption (W) **235/280
Noise Level (dB(A)) (SLOW/HIGH) 37/39
Air Output m3/h 340
Water Tank (L) 5
Dimensions (ΠxΒxΥ) (mm) 355*220*565
Net weight / Gross weight (kg) 12/13
Lenght of Drain Horse (m) 2
Lenght of Power Cord (m) 1.94
Type ***Compressor
Operation Temperature Range (°C) 3-40
Consumption values may vary depending on the relative humidity in the room of
operation.
**30W Consumption during the fan operation.
The fan only operation is a function that cannot be manually selected. It is
automatically selected when the moisture content in the room is lower than that set
by the MODE button.
When Low Fan Speed is set, the consumption can reach a maximum of 240W,
regardless of the mode (MODE) that has been selected.
When the Medium or High Fan Speed is set, the consumption may reach a
maximum of 265W. The deviation rate of the above values is +/- 5.
***The dehumidifier Puredry PD2419 Sofia is specially design to operate with the
new technology R-290 refrigerant, which is enviromental friendly.
*Choosing the correct dehumidifier should be based on the following:
l The size of the room
l The room temperature
l The relative humidity
l The room insulation
9
EN

6.GETTING TO KNOW YOUR DEHUMIDIFIER
Air Outlet
Removable
water tank
Control Panel
Casters
This unit has preinstalled
casters, positioned on
the bottom four corners
of the unit.
EN10
Water
Tank
Power
Supply Cord
Handle
LED Indicator
Air Inlet
Continuous
Drainage

7.CONTROL PANEL • INDICATORS
LED INDICATOR
When the user set the room humidity level, the led display shows the users
choice. When the user set the timer, the diplay show the hours.
EN 11
MODE LOCK HUM
SLEEP/RESETTIMER
SPEED Sofia PD2419
POWER
When the user press the HUM SET button for 4 seconds, the LED display shows the
room temperature and the indicator turns on.
When the water tank is full, this indicator will turn on to remind the user that the
water tank is full and it must be empty.
When the user set the humidity level, this indicator turns on. This indicator is also
on when the product shows the room humidity level.
TEMPERATURE INDICATOR
TANK FULL INDICATOR
HUMIDITY INDICATOR
AUTO INDICATOR
The AUTO indicator turns on, when the user select this mode from the MODE
button.

EN
12
The DRYER indicator turns on, when the user seLect this mode from the MODE
button.
DRYER INDICATOR
Press the SPEED button to select the fan speed between the low speed andthe
high speed. With HIGH speed the dehumidification runs faster, with LOW speed
the noise level is low.
When the user set the high fan speed this indicator turns on. When the machine
speed change this indicator turns off.
SPEED BUTTON
HIGH FAN SPEED INDICATOR
CONTROL PANEL LOCK INDICATOR
When the panel lock is enabled, this indicator will light up. No button is working.
When the user disable the panel lock, all buttons are working and the indicator
shut down.
The LED color changes, according to the relative humidity level of the room.
When the humidity is bellow 45%, the LED color becomes blue.
When the humidity is between 45% and 65%, the LED color becomes green.
When the humidity is above 65% the LED color becomes red.
COLOR LED INDICATOR
8.CONTROL PANEL • FUNCTIONS
By pressing the ''POWER'' button the dehumidifier turns on or off. The ''POWER''
button and the display will turn on. The default mode is in 50% relative humidity
level, using the high fan speed.
ON/OFF

CHILDREN LOCK BUTTON
HUMIDITY SET BUTTON
TIMER BUTTON
EN 13
Press this button to set the humidity level. The user can set the level between
30%-80% by step 5%. While the adjustment is taking place, the count after 80%
returns to 30%. Press and hold this button for 4 second, and the room
temperature will apear.
By pressing this button for 4 seconds, the Lock panel function enables. In this
function no button is working. In order to return to the previous state, hold the
Lock button for another 4 seconds.
Press the ''Timer'' button to set the time which the dehumidifier will start or end its
operation. The Timer indicator and the screen will light up. The user can set the
time between 1-24 hours with step every 30 minutes. The the timer set value is
"00", it means that the Timer is disabled.
MODE SELECTION
By pressing the mode button, the user choose between auto mode or dryer mode.
AUTO MODE
In this mode the relative humidity level is 50% and the fan operates at high speed
mode. Press the HUM set button to adjust the relative humidity level to your
preference between 30% and 80% by 5% step each time you press the HUM button.
After 5 seconds of inaction the setting is saved.
DRYER MODE
When the function is selected, the fan operates in high speed mode. The user
cannot change the fan speed between LOW and HIGH. During this function the
compressor operates continuously, despite the relative humidity level of the room.
For drying clothes place the dehumidifier in a small room nearby the clothes rack
and close the door. The machine should be at a distance of 40-50cm from the
clothes rack and not beneathe them. For a quick result, clothes should be wringed
out good.
SLEEP mode / RESET mode button
By pressing this button, the SLEEP function is activated. The dehumidifier operates
in LOW fan speed, and adjust the relative humidity between 57%-63%. It is no
allowed to change the fan speed or the relative humidity level.
By pressing and holding the SLEEP button, the RESET function is activated. In this
way the Filter change indicator is reset.

SAVE ENERGY FUNCTION
When the machine is switched on for the first time, the product
should entry the energy saving operation. In order to do that, the
user must select the dryer mode for 5-10 seconds until the
compressor turns on. Next the user select the relative humidity levels
of the room. When relative humidity target has been reached, both
compressor and fan stops operating. After 30 minutes, the fan
starts only, operating for 5 minutes to check the humidity levels. If
the humidity increased the dehumidifier start to operate again both of
compressor and fan. If not, it continue to not operate (standby) for
another 30 minutes. With this smart save energy operation, the
dehumidyfier drops as soon as possible the humidity levels with the
lower possible power consumption.
In any case that the compressor does not start from the beginning (lower room
humidity that the user sets) the product will operate only the fan.
EN
14
HEPA&CARBON FILTER
High quality HEPA and Active Carbon air filter
2 in 1 air filter, necessary for those who suffer from allergies, this HEPA filter is
laboratory checked to hold up to 99,97% from air pollutants ( with size up to 0.1
microns), including harmful micro-particles (PM1), bacterias, pollen and microbes.
At the same time the Carbon filter drains unpleasant odors, toxic gases, harmful
smoke from cigarettes, color paint vapors etc.

9.WATER TANK & DRAIN HOSE
There are two ways to remove collected water. Before you empty the water tank,
make sure that you have turned off and diconected the device from the power supply.
1. Using the water bucket
When the water tank is full, the alarm will beep and the water full indicator will turn on.
•Slowly remove the bucket. Grip the handle with caution, and carefully pull outwards so
the water does not overflow. Do not place the tank on a floor that its not straight or
levelness . Doing so the tank will fall and the water will be spilled on the floor.
•Empty the water from the tank and place it again in to the device. The water tank,
must be securely and properly placed, for the dehumidifier to operate.
•When the water tank is re-installed the unit will automatically restart.
Caution! Clean the water tank with clean water if it is needed to. Do not use hot water
or chemicals.
•When you remove the tank, do not touch any parts
inside the unit, as you may damage the device.
•Be sure to gently place the tank into the dehumidifier.
•Do not drink or use the collected water from the
device
•Wipe any excess water on, or in, the unit when
removing the tank.
15
EN

Caution: water hose should never be bend or twisted!
2. Continuous draining
Water automatically can be emptied into a floor drain by attaching the unit
with a water hose.
•Remove the water tank and attach the drain hose to a suitable
drainage facility. Make sure the hose is attached securely to avoid any
leaks and place it as deep as possible to ensure the right drainage.
•The dehumidifier should be placed on a flat surface in an upright position.
•Place the end of the hose into the drain and make sure that the water flows
naturally. For correct drainage, make sure the hose stays below the level of
the drain hose outlet.
When the continuous drainage feature is not being used,
remove the drain hose from the drain hose outlet.
10.STORAGE
When unit is inactive for an extended period of time please make sure you follow
the instructions below, for an appropriate storage of your appliance:
•Turn unit off allowing one day before storage.
•Remove the drain hose (if attached).
•Clean the removable parts of the device, water bucket and air filter.
GR
16
•Store the dehumidifier in upright position, in a dry, well ventilated area and
avoid direct sunlight.

NOTE: Do not use water to clean the Hepa&Carbon filter.
Clean it carefully with a vacuum cleaner.
11.MAINTENANCE & CLEANING
Before performing any maintenance or cleaning of the dehumidifier, make sure
that it is unplugged.
l Cleaning the filter:
Use water and mild detergent to clean the dehumidifier.
•Do not use abrasive cleaning agents or solvents; use a brush or vacuum
attachments
•Do not use a dishwasher to clean the filter.
•Do not apply any water directly on or into the device while cleaning, as it may
cause rust, insulation deterioration or electrical shock.
•Allow the filter to completely dry before re-installing.
The filter should
be checked and
cleaned
every 5 days.
EN 17
l Hepa & Carbon filter replacement:
The Hepa & Carbon filter is optional, it should be replaced after 3-4 months of use, it
depends on the house air pollutant. It must be replaced with an authentic Puredry's
filter for maximum results.

12. FREQUENTLY ASKED QUESTIONS
& TROUBLESHOOTING
Are dehumidifiers
costly? For about the first month of use, the dehumidifier operates
intensively. This will gradually decrease within time, since the
dehumidifier will have been calibrated in its working
environment. Condensed households may sometime be
significantly expensive to heat. The use of a dehumidifier
may lower energy cost.
Where should the
dehumidifier be
placed ideally?
For optimal results, it is suggested that the dehumidifier is
placed in a central area. Doors within the household should be
open in order for the dehumidiifer to enhance its operatio..
Can the filter be
replaced by another
HEPA type filter?
The dehumidifier’s filter cannot be replaced by any other type
of filter since it is specifically designed to operate with this unit.
Which is the
appropriate room
humidity level?
Maintaining a proper home humidity level is essential for your
well-being and that of your household. Extreme fluctuations
cause adverse effects on both; low humidity may cause
respiratory problems and damage on wooden doors, windows,
and furniture, and make you vulnerable to electric shocks due
to increased static electricity. On the other hand, high humidity
may promote mold growth, serving as breeding grounds
for various bacteria and resulting in poor health and also a
damaged home. The ideal humidity levels fluctuate between
50% to 60%.
Why does
condensation persist
on windows even
with dehumidifier’s
use?
When the desired humidity level is reached, there is a
possibility of partial humidity formation on windows. This
occurs due to the temperature variation between the window
and the external weather conditions.
•Operating the dehumidiifer should significantly reduce
condensation formation on window.
Can i wash
the Hepa&Carbon
filter?
You can not wash the HEPA&Carbon filter. That is because
the carbon will lost it's nature restraint to chemicals,
unpleasant smells, and smoke from cigarette.
EN
18

EN
How much time is
needed to dry my
clothes?
The exact time needed to dry clothes depend on many factors,
the room's temperature, the humidity level, the moisture of the
clothes etc., so there is no standard time since of these variable
factors mentioned above.
Why does the
dehumidifier
continue its
operation even
though the desired
humidity level has
been reached?
When the dehumidiifer reaches its set point it will continue
operating until humidity level reaches the desired setting with
a tolerance of 2-5%, then the compressor will stop operating
and soon after the fan will stop operating also.
The dehumidifier is
not a chilling device.
What could be the
cause of cold air
being extracted?
The dehumidifier operates by intaking condensed air removing
any moisture and sending it back in the area it operates. If
you are standing near the dehumidiifer while operating you
may feel that the air coming out of the fan is cooler due to the
diffusion reality, it is at the same room-temperature but with
less humidity.
The unit does not start
l Make sure the dehumidifier’s plug is placed completely into the socket.
l Check the house fuse/circuit breaker box.
l Check whether the power cord is damaged.
l Check the water bucket, if it is full, empty it.
l Check if the dehumidifier has reached its preset level.
l Make sure the water bucket is positioned properly.
l Room temperature is lower or higher than the advised operational range.
l Check whether the humidity level has been set in high level.
Dehumidifier does not dry the air as efficient
l Make sure that the dehumidifier has been operating enough time to remove the
moisture.
l Make sure there are no curtains, blinds or furniture blocking the front or back of the
dehumidifier.
l The humidity selector may not be set low enough.
l Make sure you have cleaned the filter as suggested. Clogged filter may result in
reduced performance.
19

EN
l All house exits (windows doors etc) where the dehumidifier is operating, should be shuted.
l Room temperature is below the advised operational range.
l There is a kerosene heater or something giving off water vapor in the room.
l The room that the device is placed is bigger than suggested.
l The humidity level is too high.
The unit makes a loud noise when operating
l The air iflter is clogged.
l The device is tilted instead of being in an upright position.
l The floor surface is not flat.
Frost build up on coils
l This is normal. This unit is supplied with an Auto defrost feature.
Drain hose water leakage
l Check the correct installation of the drain hose.
l Check for any blockage or damage of the drain hose.
Understanding Error and Protection codes
Error Codes:
CL- When the room temperature is below <5°C, the code CL appears. At this state the
compressor does not work, but the other functions works normally.
LO- When the relative humidity is below 20* RH, the code LO appears. At this state
the compressor does not work, but the other functions works normally.
HI- When the relative humidity is above 95% RH, the code HU appears. At this state
both the compressor and the other functions works normally
NOTE: All the pictures in the manual are for explanatory purposes only. The actual
shape of the unit you purchased may be slightly dierent, but the operations and
functions are the same.
In the event of any of the above-mentioned malfunctions, turn
off the unit, and check for any obstructions. Restart the unit, if
the malfunction persists, turn off the unit and unplug. Contact
the manufacturer or a qualified technician for service.
20
CH- When the room temperature is above >38°C, the code CH appears. At this state the
compressor does not work, but the other functions works normally.
E2- This error code appear when the humidity and temperature sensor has been
damaged. Turn off the product and contact the technical department of the company
immidiately.
Table of contents
Languages:
Other Puredry Dehumidifier manuals

Puredry
Puredry PD 20L Face Lift User manual

Puredry
Puredry PD 210L User manual

Puredry
Puredry PDDW 12100 Famous User manual

Puredry
Puredry PDD 8519 FAMOUS User manual

Puredry
Puredry DESIGN SERIES PD 130LA User manual

Puredry
Puredry PDD 10L Famous User manual

Puredry
Puredry PDD 200M User manual

Puredry
Puredry PDD 85200 FAMOUS User manual

Puredry
Puredry PD 170L User manual

Puredry
Puredry PD 130L User manual