5
Reverse Osmosis Undersink Water Filter Systems
Installation Procedure
in the desired location. Choose a location where water spillage will not cause damage and out of
direct sunlight.
2. Isolate water supply. Uninstall the connections on the cold water line and connect to the GREEN
tubing.
valve to food service equipment.
4. Install the drain clamp by drilling a 4 mm hole in the waste pipe. Position the drain clamp above
the trap. Connect ¼” (BLACK) drain tube to drain clamp and tighten compression nut. Do not allow
drain tube to protrude more than 10 mm into drain, making sure the holes in the drain and the
clamp are exactly aligned. This can be done by inserting a thin Phillips screwdriver through them
whilst tightening the clamp.
5. When connecting the green, red, blue and yellow tubes leave plenty of extra length so that the
Note
tank outlet and ensure valve is open. Connect YELLOW tube to Storage Tank.
8. Open up the water supply, (CO-RO270P models: turn on the booster pump) and allow the storage
to drain. This should continue for several hours until tank is full. When tank is full, the pressure in
inlet water. To check this, check if water is running to drain. Once tank is full no water should run to
9. Reverse osmosis systems produce water slowly. To begin with, t he tank will take 3 to 4 hours to
10. Check all connections are tightened properly. Check for leaks.
11. When the unit is in place and the water lines are installed, the unit should be run for 4 hours before
without use, or damage to the membrane may occur. Please enquire if this is the case.
than 2 weeks, the cartridges may need replacing.
should be replaced when water quality deteriorates or every 18 - 24 months, depending on
incoming water quality.
For best performance use only genuine Puretec replacement cartridges and cartridges that are
suitable for this system.
NOTE: When removing the membrane from the packaging, only remove the outer shrinkwrap
packaging, DO NOT remove any other packaging from the membrane.