QTM-DRIVE LED POWER SUPPLY 60W–200W
©
2020
Q-T
ran
Inc.
All
rights
reser
ved
|
155
Hill
St.
Milf
ord,
CT
06460
|
203-367-8777
|
[email protected] |
www
.q-tran.com
Specification
subject
to
change.
Rev-11-19-20DMX in/LedSync out
• Use these connectors when the driver is used in a DMX network. For DMX in, connect the network cable’s DMX+, DMX-
and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in
shield connector respectively. ForLedSync out, connect the network cable’s DMX+, DMX- and DMX shielding wire to the
LedSync out+, LedSync out- and LedSync shield connector respectively.
DALI
• Use these connectors to connect the driver to a DALI network. Always combine a DA+ and DA- connector for either data
input or data output. A separate DALI power supply is required to power the DALI bus.
INPUT
• Voltage: 120 - 277 VAC, 50/60Hz
• Current, max per driver:
1.05A at 120V/60Hz
0.5A at 230V/50Hz
0.45A at 277V/60Hz
OUTPUT
• Power per driver: 100W max
• Voltage: 12V/24V output
• Current
RGBW @ 12V: 1.25A per output
RGBW @ 24V: 1A per output
• Output
RGB @ 12V: 1.66A per output
RGB @ 24V: 1.33A per output
• Current max: 5A common anode
ENVIRONMENTAL
• Ta operating range : -40°F ~ +122°F
• Tc max : 185°F
• Lifetime : 50K hours at 122°F
• MTBF : 480,000 hours
COMPLIANCE / SAFETY
• Class 2 output.
• Class A sound rating
• FCC: Title 47CFR Part 15 Class B
• The wiring inside electrical enclosures shall comply with the
600V/105 ºC or higher.
• CSA certified
: UL-2108
: UL-8750
: CSA C22.2 No 250.0-08
: CSA C22.2 No 250.13-14
NOTE: All measurements have been carried out at maximum load in free air without heat sink.
Wiring Diagram
Pay attention when connecting the LED groups:
•polarity reversal results in no light output and often damages
the LEDs
•combining + and -of different groups
damages the driver
2
1
9 mm
0.35 inch
0.5-1.5 mm 2
AWG 20-16
LED wire length: Maximum wire length
from LED driver to LED engine at full load:
AWG value 20 18 16
Distance (ft)
NOTE: Longer wire lengths increase EMI susceptibility.
M_+
120-277VAC
50-60Hz
DA -
+
DA -
+
~
~
1 2
DMX in shield
DMX in
-
DMX in +
LedSync out shield
LedSync out
-
Ext in
-
Ext in +
+
-
+
-
DALI
{
N
LVAC
120-277
12V / 24V DIP switch
24V 12V
Non functional
RR
WR BG
R
R
Common anode
4 LED groups, 4 control channels
2
1
0.2-1.5 mm 2
9 mm
0.35 inch
AWG 24-16
46 72 118
NOTE