The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1FR LO
K8.0 (115 metric) Quick
Response Sprinklers
Model F1FR LO Sprinkler Types
Standard Spray Upright
Standard Spray Pendent
Conventional
Model F1FR LO Recessed Sprinkler Types
Recessed Standard Spray Pendent
For Model F1FR 1/2" K 5.6 (80), 4.2 (60) and 2.8 (40) Sprinkler
Types refer to Bulletin 014 for technical specifications and
approvals.
Listings and Approvals
1. Listed by Underwriters Laboratories, Inc. (UL)
2. Listed by Underwriters’ Laboratories of Canada (ULC)
3. Factory Mutual Approvals (FM)
4. Loss Prevention Council (LPCB, UK)
5. VdS Schadenverhütung GmbH
6. EC Certificate: 1438-CPD-0049 (R3612)
1438-CPD-0048 (R3622)
1438-CPD-0047 (R3672)
UL Listing Category
Sprinklers, Automatic and Open
Quick Response Sprinkler
ULGuide Number
VNIV
Product Description
Reliable Models F1FR LO and F1FR LO Recessed Sprinklers
are quick response sprinklers which combine the durability of a
standard sprinkler with the attractive low profile of a decorative
sprinkler.
The Models F1FR LO and F1FR LO Recessed automatic
sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers
have demonstrated response times in laboratory tests which
are five to ten times faster than standard response sprinklers.
This quick response enables the Model F1FR LO and F1FR LO
Recessed sprinklers to apply water to a fire much faster than
standard sprinklers of the same temperature rating.
The glass bulb consists of an accurately controlled amount of
special fluid hermetically sealed inside a precisely manufactured
glass capsule. This glass bulb is specially constructed to provide
fast thermal response. The balance of parts are made of brass,
copper and beryllium nickel.
At normal temperatures, the glass bulb contains the fluid in
both the liquid and vapor phases. The vapor phase can be seen
as a small bubble. As heat is applied, the liquid expands, forcing
Upright
the bubble smaller and smaller as the liquid pressure increases.
Continued heating forces the liquid to push out against the bulb,
causing the glass to shatter, opening the waterway and allowing
the deflector to distribute the discharging water.
The temperature rating of the sprinkler is identified by the
color of the glass bulb.
Application
Quick response sprinklers are used in fixed fire protection
systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector
style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association
or the approving Authority Having Jurisdiction. Quick response
sprinklers are intended for installation as specified in NFPA 13,
FM Global Loss Prevention Data Sheet 2-8N or other applicable
standards. Quick response sprinklers and standard response
sprinklers should not be intermixed.
Installation
Quick response sprinklers are intended for installation as
specified in NFPA 13, FM Global Loss Prevention Data Sheet
2-8N or other applicable standards. Quick response sprinklers
and standard response sprinklers should not be intermixed.
The Model F1FR LO Recessed Quick Response Sprinklers
are to be installed as shown. The Model F1 or F2 Escutcheons
illustrated are the only recessed escutcheons to be used with
the Model F1FR LO Sprinklers. The use of any other recessed
escutcheon will void all approvals and negate all warranties.
Pendent
Conventional Recessed Pendent
(Model FP Shown)
Multilingualdocument:
Select your language below
Bulletin 136 Rev. T_Multilingual
Bulletin 136 Rev. T_Multilingual
2
136FG02
Technical data:
Models Response Deflector
Orientation Nominal
K-factor Thread Size Max.
Working
Pressure
Min.
Working
Pressure
Temperature
Rating Finish
F1FR LO Quick
Response
Upright
Pendent
Conventional
K 8.0
(115 metric)
3/4" NPT
or
ISO7-1R
3/4
175 psi (1) 7 psi See “Temperature
Ratings” Table See
“Finish Table”
Material Data:
Frame Deflector Load Screw Cup Washer Bulb
DZR Brass
QM Brass CDA Alloy 510 CDA Alloy 210, 220, 314, 316, 360
or
CDA Alloy 544
CDA Alloy 314
or
CDA Alloy 353
Nickel Alloy 440 or Alloy 360 coated
with PTFE Adhesive Tape Glass
See “Installation Data” table from page 3 for more details.
(1) Model F1FR LO Pendent, Recessed Pendent, and Upright sprinklers (SIN R3612 and R3622) are cULus Listed for 250 psi (17 bar).
DEFLECTOR
LOAD SCREW
BULB
WASHER
FRAME
CUP
3
136FG05_C136FG01_G
Model F1FR LO Quick Response Upright, Pendent and Conventional Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Sprinkler Type
Nominal
K-factor Sprinkler
Height Approval
Organization
Sprinkler
Identification
Numbers (SIN)
US Metric SSU SSP
Standard-Upright (SSU) and pendent (SSP) Deflectors Marked to Indicate Position
17/32" (20 mm) Large Orifice with 3/4" NPT (R
3/4) Thread 8.0 115 2.3" (58 mm) 1, 2, 3, 4, 5, 6 R3622(1)(2)(3) R3612(2)(3)
Conventional-Install in Upright or Pendent Position
20 mm Large Orifice with 3/4" NPT (R
3/4) Thread 8.0 115 58 mm 4R3672
(1) Polyester coated upright UL and ULC listed corrosion resistant R3622.
(2) FM Approved for polyester coated sprinkler. R3622, R3612.
(3) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant
Upright Pendent Conventional
Model F1FR LO Quick Response Recessed Pendent Sprinkler(1)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Orifice Thread Size “T” Nominal K-factor Sprinkler
Height
Approval Organization(1) Sprinkler
Identification
Numbers (SIN)
US Metric F1 F2 FP
17/32" (20 mm) 3/4" NPT (R
3/4)8.0 115 2.3" (58 mm) 1, 2 1, 2, 3 1, 2 R3612(2)
(1) Refer to escutcheon data table for dimensions.
(2) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant
TURN COLLAR
UNTIL TIGHT
AGAINST SPRINKLER
WRENCH BOSS
F1 ESCUTCHEON
3/4" (19 mM)
ADJUSTMENT
F2 ESCUTCHEON
1/2" (12.7 mM)
ADJUSTMENT F1 ESCUTCHEON
AT MAXIMUM RECESS = 7/8" (22.2 mM)
AT MINIMUM RECESS = 1 5/8" (41.3 mM)
F2 ESCUTCHEON
AT MAXIMUM RECESS = 1 1/8" (28.6 mM)
AT MINIMUM RECESS = 1 5/8" (41.3 mM)
1" x 3/4"
REDUCER
1/8"
(3.2 mM)
227/32" DIA.
(72.2 mM)
RECESSED PENDENT W/F1 OR F2 ESCUTCHEON
*SPRIKLER NOT FM APPROVED WITH F1 ESCUTCHEON
21/4" HOLE
DIA. (57.2 mM)
115/16" DIA.
(49.2 mM)
RECESSED PENDENT W/FP ESCUTCHEON
*SPRINKLER NOT FM APPROVED WITH FP ESCUTCHEON
25/8" DIA. (66.7 mM)
HOLE IN CEILING
25/16" DIA.
(58.7 mM) CUP
CEILING
1/2" (12.7 mM)
ADJUSTMENT
31/4" DIA.
(82.6 mM)
1" x 3/4" REDUCER
FACE OF FITTING TO FACE OF
CEILING DIMENSION
AT MAXIMUM RECESS = 1 1/2" (38 mM)
AT MINIMUM RECESS = 1" (25.4 mM)
AT MAXIMUM RECESS = 9/16" (14.3 mM)
AT MINIMUM RECESS = 1" (25.4 mM)
FACE OF FITTING TO FACE OF
CEILING DIMENSION
F1 ESCUTCHEON
AT MAXIMUM RECESS = 1" (25.4 mM)
AT MINIMUM RECESS = 3/8" (9.5 mM)
F2 ESCUTCHEON
AT MAXIMUM RECESS = 3/4" (19 mM)
AT MINIMUM RECESS = 3/8" (9.5 mM)
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by Recycled
Paper
Revision lines indicate updated or new data.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products
manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
When installing Model F1FR LO Sprinklers, use the Model D
Sprinkler Wrench. When installing Model F1FR LO Recessed
Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler
Wrench. Any other type of wrench may damage these sprinklers.
Note: A leak tight 1/2" NPT (R1/2) sprinkler joint can be obtained
with a torque of 8-18 ft-lb (11-24 N-m). Do not tighten sprinklers
over maximum recommended torque. It may cause leakage or
impairment of the sprinklers.
Glass bulb sprinklers have orange bulb protectors to minimize
bulb damage during shipping, handling and installation.
REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER
SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION.
Removal of the protectors before this time may leave the bulb
vulnerable to damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE PROTECTORS
BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS
TO REMOVE THE PROTECTORS.
Temperature Ratings
Classification
Sprinkler
Temperature
Maximum
Ambient
Temperature Bulb
Color
°F °C °F °C
Ordinary 135 57 100 38 Orange
Ordinary 155 68 100 38 Red
Intermediate 175 79 150 66 Yellow
Intermediate 200 93 150 66 Green
High (1) 286 141 225 107 Blue
(1) Not Available for recessed sprinklers.
Maintenance
The Models F1FR LO and F1FR LO Recessed Sprinklers
should be inspected and the sprinkler system maintained in
accordance with NFPA 25. Do not clean sprinklers with soap
and water, ammonia or any other cleaning fluids. Remove
dust by using a soft brush or gentle vacuuming. Remove any
sprinkler which has been painted (other than factory applied)
or damaged in any way. A stock of spare sprinklers should be
maintained to allow quick replacement of damaged or operated
sprinklers. Prior to installation, sprinklers should be maintained
in the original cartons and packaging until used to minimize the
potential for damage to sprinklers that would cause improper
operation or non-operation.
Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Recessed Pendent
Finishes (1)(2)
Standard Finishes
Sprinkler Escutcheon
Bronze
Chrome Plated
White Polyester Coated (4)(5)
Brass
Chrome Plated (3)
White Painted (3)
Special Application Finishes
Sprinkler Escutcheon
Electroless Nickel PTFE (6)
Bright Brass
Black Plated
Black Paint
Off White
Satin Chrome
Electroless Nickel PTFE
Bright Brass
Black Plated
Black Paint
Off White
Chrome Dull
(1) Other finishes and colors are available on special order. Consult the
factory for details.
(2) FM Approvals is limited to bronze and brass, chrome or black plated
finishes only.
(3) FP Push-on/Thread-off escutcheon.
(4) cULus listed corrosion resistance. SIN R3622.
(5) FM Approved for SIN R3622, R3612
(6) cULus listed corrosion resistant SIN R3622 & R3612
Note: For 1/2" orifice pendent FM approved white polyester
coated, cULus listed white and black polyester and Electroless
Nickel PTFE Plated corrosion resistant sprinklers refer to
bulletin 014.
Maximum Working Pressure
175 psi (12 bar)
SIN R3612 & R3622 cULus listed for 250 psi (17 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Type
8. Escutcheon Finish (where applicable)
Note: When Model F1FR LO Recessed sprinklers are ordered,
the sprinklers and escutcheons are packaged separately.
EG. Printed in U.S.A. 12/15 P/N 9999970027

Other Reliable Irrigation System manuals

Reliable XL Manual

Reliable

Reliable XL Manual

Reliable LT56 Series User manual

Reliable

Reliable LT56 Series User manual

Reliable F156 Series User manual

Reliable

Reliable F156 Series User manual

Reliable Reliable User manual

Reliable

Reliable Reliable User manual

Reliable F3-80 Dry Pendent User manual

Reliable

Reliable F3-80 Dry Pendent User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable XL User manual

Reliable

Reliable XL User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR-SS Series User manual

Reliable

Reliable F1FR-SS Series User manual

Reliable RFC30 LL User manual

Reliable

Reliable RFC30 LL User manual

Reliable HL22 User manual

Reliable

Reliable HL22 User manual

Reliable DH56 HSW User manual

Reliable

Reliable DH56 HSW User manual

Reliable JL-14 Manual

Reliable

Reliable JL-14 Manual

Reliable RFC Series Manual

Reliable

Reliable RFC Series Manual

Reliable F1S5-FSLO User manual

Reliable

Reliable F1S5-FSLO User manual

Reliable DH56 HSW-PL User manual

Reliable

Reliable DH56 HSW-PL User manual

Reliable F1FR80VdS Series Manual

Reliable

Reliable F1FR80VdS Series Manual

Reliable F3QR56 User manual

Reliable

Reliable F3QR56 User manual

Reliable F1-SS Series User manual

Reliable

Reliable F1-SS Series User manual

Reliable G5 Series User manual

Reliable

Reliable G5 Series User manual

Reliable G User manual

Reliable

Reliable G User manual

Reliable F1FR-300 User manual

Reliable

Reliable F1FR-300 User manual

Reliable G6-80 User manual

Reliable

Reliable G6-80 User manual

Reliable XL Commercial User manual

Reliable

Reliable XL Commercial User manual

Popular Irrigation System manuals by other brands

Tyco DS-3 Series General description

Tyco

Tyco DS-3 Series General description

SNOWJOE AquaJoe AJ-IS10WB instructions

SNOWJOE

SNOWJOE AquaJoe AJ-IS10WB instructions

Rain SuperPro S075 S Setting instructions

Rain

Rain SuperPro S075 S Setting instructions

Viking VK514 Technical data

Viking

Viking VK514 Technical data

Tyco rapidresponse RSV-1 quick start guide

Tyco

Tyco rapidresponse RSV-1 quick start guide

Tyco TY-L Series manual

Tyco

Tyco TY-L Series manual

TOOLCRAFT 1561111 operating instructions

TOOLCRAFT

TOOLCRAFT 1561111 operating instructions

Viking VK3541 Technical data

Viking

Viking VK3541 Technical data

K-Rain RPS75 Setting instructions

K-Rain

K-Rain RPS75 Setting instructions

K-Rain RPS 46 instruction manual

K-Rain

K-Rain RPS 46 instruction manual

AQUAJOE SJI-OMS18 quick guide

AQUAJOE

AQUAJOE SJI-OMS18 quick guide

AQUAJOE AJ-IS6WB user manual

AQUAJOE

AQUAJOE AJ-IS6WB user manual

WatchDog WatchDog 3349SS product manual

WatchDog

WatchDog WatchDog 3349SS product manual

GEM F892 manual

GEM

GEM F892 manual

Tyco Rapidresponse LFII Series manual

Tyco

Tyco Rapidresponse LFII Series manual

ROCAMED ENDOFLOW II MEN01 Instructions for use

ROCAMED

ROCAMED ENDOFLOW II MEN01 Instructions for use

Eden 94105EDAMZ quick start guide

Eden

Eden 94105EDAMZ quick start guide

Toro Super 800 Series installation instructions

Toro

Toro Super 800 Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.