manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable F1S5-FSLO User manual

Reliable F1S5-FSLO User manual

Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1S5-FSLO with ½” threads
Model F1S5-FS56, Model F1S5-FS42
Special Response
Flat Spray Sprinklers
Bulletin 023 Rev. B
Bulletin 023 Rev. B
Model F1S5-FSLO, K115, Large Orice Flat Spray-
Sprinkler
Types
Standard Pendent
Models F1S5-FS56, F1S5-FS42 and
F1S5-FSLO Flat Spray Sprinkler
Types
Standard Pendent
Listings & Approvals
F1S5-FSLO
• VdS Schadenverhütung GmbH: Certicate
Gxxxxx
• CE Certicate: Standard EN 12259-1, Certicate of
constancy of performance 0786-CPR-xxxxx
F1S5-FS56
• VdS Schadenverhütung GmbH: Certicate
G4080046
• CE Certicate: Standard EN 12259-1, EC-Certicate
of conformity 0786-CPD-40241
F1S5-FS42
• VdS Schadenverhütung GmbH: Certicate
G414024
• CE Certicate: Standard EN 12259-1, Certicate
of constancy of performance 0786-CPR-40297
Product Description
The F1S5-FS56, F1S5-FS42 and F1S5-FSLO Flat Spray
Sprinklers are designed for installation in accordance with
CEA 4001 or EN 12845 (Automatic Sprinkler Systems - De-
sign, Installation and Maintenance). The spray pattern cre-
ated by this sprinkler makes this an excellent choice for ap-
plications with lower clearance above the suspended open
ceilings and in racks.
The F1S5-FS56, F1S5-FS42 and F1S5-FSLO Flat Spray
Sprinklers with shield are used in applications where there
are high and lower level sprinklers. The shield is to help pre-
vent the lower level sprinklers from getting wet by the higher
level sprinklers.
The F1S5-FS56, F1S5-FS42 and F1S5-FSLO Flat Spray
Sprinkler utilize a special response frangible 5.0mm glass
bulb. The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside of a pre-
cisely manufactured glass capsule. This glass bulb is special-
ly constructed to provide fast thermal response.
Pendent
Pendent with shield
At normal temperatures, the glass bulb contains the fluid
in both the liquid phase and in the vapor phase. The vapor
phase can be seen as a small bubble. As heat is applied, the
liquid expands forcing the bubble smaller and smaller as the
liquid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distribute
the discharging water.
The F1S5-FS56, F1S5-FS42 and F1S5-FSLO Flat Spray
Sprinkler temperature ratings are identied by the color of
the glass bulb capsule.
Models F1S5-FS56, F1S5-FS42 and F1S5-FSLO Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Sprinkler Type
Standard–Pendent (SSP)
Deflectors Marked to Indicate Position
K Factor Sprinkler
Height
Approval
Organizations
Sprinkler Identication
Number (SIN)
US Metric
1/2” (15mm) Standard Orice with 1/2” NPT Thread 5.6 80 2.25” (57mm) VdS RA2314
1/2” (15mm) Standard Orice with R1/2 BSPT Thread 5.6 80 2.25” (57mm) VdS RA2314
3/8” (10mm) Standard Orice with R1/2 BSPT Thread 4.2 57 2.25” (57mm) VdS RA2315
3/4” (20mm) Standard Orice with R1/2 BSPT Thread 8.0 115 2.28” (58mm) VdS RA2312
Pendent
Model F1S5-FS56 with shield
Models F1S5-FS56, F1S5-FS42 and F1S5-FSLO Pendent Sprinklers with shield
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orice
Thread
Size
K Factor Sprinkler
Height
Approval
Organizations
Sprinkler Identication
Number (SIN)
US Metric
1/2” (15mm) 1/2” NPT 5.6 80 2.25” (57mm) VdS RA2314
1/2” (15mm) R1/2” BSPT 5.6 80 2.25” (57mm) VdS RA2314
3/8” (10mm) R1/2” BSPT 4.2 57 2.25 (57mm) VdS RA2315
3/4” (20mm) R1/2” BSPT 8.0 115 2.28 (58mm) VdS RA2312
Shield Data
Part No. Approvals “A”
Dimension
“B”
Dimension
“C”
Dimension
6999995574 VdS 4 17/32”
(115mm)
1 15/16”
(49mm)
9/16”
(14mm)
2.
Models F1S5-FS56, F1S5-FS42, F1S5-FSLO
Pendent Sprinklers, F1S5-FS56, F1S5-FS42
and F1S5-FSLO Pendent Sprinklers with
shield
Application
Models F1S5-FS56, F1S5-FS42 and F1S5-FSLO Flat Spray
Sprinklers are used in concealed spaces, suspended open
ceiling and in racks in accordance with CEA 4001 Sprinkler
System Planning) and EN 12845 (Automatic Sprinkler Sys-
tems - Design Installation and Maintenance).
Installation
Models F1S5-FS56, F1S5-FS42 and F1S5-FSLO Flat Spray
Sprinklers are special response sprinklers intended for instal-
lation as specied in CEA 4001 and EN 12845. They must
also be installed with the Model D Sprinkler Wrench speci-
cally designed by Reliable for use with these sprinklers.
When installing Models F1S5-FS56, F1S5-FS42 and F1S5-
FSLO Pendent with shield use the Model GFR2 Sprinkler
Wrench. Any other type of wrench may damage these sprin-
klers.
Note: A leak tight ½” NPT sprinkler joint can be obtained
with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tight-
en sprinklers over maximum recommended torque. It may
cause leakage or impairment of the sprinklers.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orice Size
4. Deflector Type
5. Temperature Rating
- Specify Bulb Size when ordering
6. Sprinkler Finish - Bronze only
Note: When Models F1S5-FS56, F1S5-FS42 and F1S5-FS-
LO Pendent Sprinkler with shield are ordered, the sprinklers
and shields are packaged separately.
Maintenance
The Models F1S5-FS56, F1S5-FS42, F1S5-FSLO Pendent,
F1S5-FS56, F1S5-FS42 and F1S5-FSLO Pendent Sprinklers
with shield should be inspected quarterly. Do not clean sprin-
klers with soap and water, ammonia or any other cleaning
fluid. Remove any sprinkler which has been painted (other
than factory applied) or damaged in any way. A stock of
spare sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
sprinklers that would cause improper operation or non-oper-
ation.
Temperature Ratings
Classication
Sprinkler
Temperature Max. Ambient
Temp.
Bulb
Color
°C °F
Ordinary
Ordinary
Intermediate In-
termediate High
57
68
79
93
141
135
155
175
200
286
100°F (38°C)
100°F (38°C)
150°F (66°C)
150°F (66°C)
225°F (107°C)
Orange
Red
Yellow
Green
Blue
Finish
Sprinkler Shield
Bronze Galvanized
3.
Reliable . . . For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many preci-
sion-made Reliable products that guard life and property from re around the clock.
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identication signs
• Fire department connections
Reliable Automatic Sprinkler Co., Inc.
(800)431–1588 Sales Ofces
(800)848–6051 Sales Fax
(914)829–2042 Corporate Ofces
www.reliablesprinkler.com Internet Address
Manufactured by
Recycled
Paper
EG. Printed in U.S.A. 05/15 P/N 9999970366
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation,
or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualied and reputable sprinkler
contractors located throughout the United States, Canada and foreign countries.
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
Revision lines indicate updated or new data

This manual suits for next models

2

Other Reliable Irrigation System manuals

Reliable F4FR-NF Manual

Reliable

Reliable F4FR-NF Manual

Reliable F1 Series Manual

Reliable

Reliable F1 Series Manual

Reliable GXLO Series Manual

Reliable

Reliable GXLO Series Manual

Reliable DH80 User manual

Reliable

Reliable DH80 User manual

Reliable XL Manual

Reliable

Reliable XL Manual

Reliable F1FR QREC Manual

Reliable

Reliable F1FR QREC Manual

Reliable RFC43 LL User guide

Reliable

Reliable RFC43 LL User guide

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable F3QR80 Series User manual

Reliable

Reliable F3QR80 Series User manual

Reliable F1FR56 User manual

Reliable

Reliable F1FR56 User manual

Reliable F1FR-FS Series User manual

Reliable

Reliable F1FR-FS Series User manual

Reliable F1-56-300 Series User manual

Reliable

Reliable F1-56-300 Series User manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable F156 Series User manual

Reliable

Reliable F156 Series User manual

Reliable N252 User manual

Reliable

Reliable N252 User manual

Reliable F3-80 Dry Pendent User manual

Reliable

Reliable F3-80 Dry Pendent User manual

Reliable JL-14 User manual

Reliable

Reliable JL-14 User manual

Reliable F4FR User manual

Reliable

Reliable F4FR User manual

Reliable G4-300 User manual

Reliable

Reliable G4-300 User manual

Reliable F3QR80 Dry Pendent Operator's manual

Reliable

Reliable F3QR80 Dry Pendent Operator's manual

Reliable F3-80 Series Manual

Reliable

Reliable F3-80 Series Manual

Reliable Non-Ferrous Concealer User manual

Reliable

Reliable Non-Ferrous Concealer User manual

Reliable F1FR-SS Series User manual

Reliable

Reliable F1FR-SS Series User manual

Reliable F1FR-300 User manual

Reliable

Reliable F1FR-300 User manual

Popular Irrigation System manuals by other brands

Toro 53707 installation guide

Toro

Toro 53707 installation guide

MiniMax MS-1 Technical data sheet

MiniMax

MiniMax MS-1 Technical data sheet

Senju Sprinkler RC-QR manual

Senju Sprinkler

Senju Sprinkler RC-QR manual

W&H OsseoSet 200 Instructions for use

W&H

W&H OsseoSet 200 Instructions for use

Tyco LFII Series Technical data sheet

Tyco

Tyco LFII Series Technical data sheet

Tyco TY-L Series manual

Tyco

Tyco TY-L Series manual

Rain elite 9 VDC instructions

Rain

Rain elite 9 VDC instructions

General Air Products Vapor Pipe Shield VPS-500A Installation, operation and maintenance manual

General Air Products

General Air Products Vapor Pipe Shield VPS-500A Installation, operation and maintenance manual

Viking MICROFAST VK345 Technical data

Viking

Viking MICROFAST VK345 Technical data

Motorola IRRInet-M DC owner's manual

Motorola

Motorola IRRInet-M DC owner's manual

Tyco ESFR-1 Assembly instructions

Tyco

Tyco ESFR-1 Assembly instructions

SNOWJOE Aqua Joe AJ-6PSTB manual

SNOWJOE

SNOWJOE Aqua Joe AJ-6PSTB manual

UNITED Nitrogen Pac SC-W Installation, commissioning maintenance

UNITED

UNITED Nitrogen Pac SC-W Installation, commissioning maintenance

IRROMETER WaterSwitch-DC Installation and operating instructions

IRROMETER

IRROMETER WaterSwitch-DC Installation and operating instructions

Tyco TY-B Series manual

Tyco

Tyco TY-B Series manual

Johnson Controls tyco TY1234 manual

Johnson Controls

Johnson Controls tyco TY1234 manual

NaanDanJain Viridix installation guide

NaanDanJain

NaanDanJain Viridix installation guide

Tyco Fire Product CENTRAL LF instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL LF instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.