manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable F156 EC Series User manual

Reliable F156 EC Series User manual

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F156 EC Series
Standard Response
Extended Coverage Spray
Bulletin 027 Rev. C
Bulletin 027 Rev. C
Model F156 EC
Extended Coverage Sprinkler
• Pendent
Model F156 EC Recessed
Extended Coverage Sprinkler
• Recessed Pendent F1/F2/FP
Approval Organizations
1. Listed by Underwriters Laboratories, Inc. and
Certified for Canada (cULus)
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Product Description
The F156 Extended Coverage Glass Bulb Sprinkler com-
bines the durability of a standard sprinkler with the attrac-
tive low profile of a decorative sprinkler. Whether installed
on exposed piping or in an office ceiling, it is functional
and attractive.
Beautifully versatile is the description for the Reliable
Model F156 Recessed Extended Coverage glass bulb
sprinkler. Recessing the sprinkler enhances its already
low profile decorative appearance, and facilitates a rapid
and perfect installation.
Model F156 Recessed Extended Coverage escutcheon
is highly adjustable. The two piece construction makes
field installation a very easy and rapid task. This also al-
lows ceiling panels to later be removed without shutting
down the fire protection system, thus facilitating mainte-
nance of above ceiling services.
The Model F156 Extended Coverage Sprinkler utilizes
a frangible glass bulb. The glass bulb consists of an ac-
curately controlled amount of special fluid hermetically
sealed inside of a precisely manufactured glass capsule.
This glass bulb is specially constructed to provide fast
thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid phase and in the vapor phase. The vapor
phase can be seen as a small bubble. As heat is applied,
the liquid expands forcing the bubble smaller and smaller
as the liquid pressure increases. Continued heating forces
the liquid to push out against the bulb, causing the glass
to shatter, opening the waterway and allowing the deflec-
tor to distribute the discharging water.
The F156 Extended Coverage Sprinkler temperature rat-
ing is identified by the color of the glass bulb capsule as
well as frame color where applicable.
Recessed Extended Coverage
Pendent F1/F2
Extended Coverage
Pendent
Recessed Extended Coverage
Pendent FP
2.
Model F156 Extended Coverage Pendent Sprinkler
Deflector: EC Pendent
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Extended Coverage - Light Hazard Occupancy
Table 1
Coverage Area
Flow Rate Pressure Nonimal Max. Area
Width x Length
K=5.6 (80)
gpm L/min psi bar ft. x ft. m x m
26 98.4 21.6 1,5 16 x 16 4.9 x 4.9
33 125.0 34.7 2,4 18 x 18 5.5 x 5.5
40 151.4 51.0 3,5 20 x 20 6.0 x 6.0
Installation Data:
Nominal
Orifice
Thread
Size
Nominal K Factor Sprinkler
Height
Temperature
Rating Sprinkler Identification
Number (SIN)
US Metric °F °C
½”
(15mm)
½” NPT
(R½) 5.6 80 2.25”
(57mm) 135, 155 57, 68 RA2745
Model F156 Recessed Extended Coverage Pendent Sprinkler
Deflector: EC Pendent
Installation Wrench: Model GFR2 Sprinkler Wrench
Approval Type: Extended Coverage - Light Hazard Occupancy
Installation Data(1):
Nominal
Orifice
Thread
Size
Nominal K Factor Sprinkler
Height
Temperature
Rating Sprinkler Identification
Number (SIN)
US Metric °F °C
½”
(15mm)
½” NPT
(R½) 5.6 80 2.25”
(57mm) 135, 155 57, 68 RA2745
(1) See Table 1 for Coverage Area.
(1) When installed directly into a tee, the escutcheon adjustment will be
reduced.
(2) Refer to escutcheon data table for dimensions.
Extended Coverage Pendent
Model F156 EC F1/F2 Model F156 EC FP
Fig. 1 Fig. 2
3.
Model F156 EC Pendent & F156 Recessed
EC Pendent Sprinklers
Application
Model F156 EC and F156 EC Recessed sprinklers are
used in fixed fire protection systems: Wet, Dry, Deluge or
Preaction. Care must exercised that the orifice size, tem-
perature rating, deflector style and sprinkler type are in
accordance with the latest published standards of the Na-
tional Fire Protection Association or the approving Author-
ity Having Jurisdiction.
Installation
Model F156 EC sprinklers are standard response sprin-
klers intended for installation as specified in NFPA 13. They
must also be installed with the Model D Sprinkler Wrench
specifically designed by Reliable for use with these sprin-
klers.
The Model F156 EC Recessed Sprinklers are to be in-
stalled with a maximum recess of ¾ inch (19mm). The
Model F1, F2, and FP Escutcheons illustrated are the only
recessed escutcheons to be used with the Model F156 EC
Sprinklers. The use of any other recessed escutcheon will
void all approvals and negate all warranties. When install-
ing Model F156 EC Recessed Pendent and EC Pendent
Sprinklers, use the Model GFR2 Sprinkler Wrench. Any
other type of wrench may damage these sprinklers.
Glass bulb sprinklers have orange covers to protect
the bulb during the installation process. REMOVE THIS
PROTECTION ONLY AFTER THE SYSTEM HAS BEEN
HYDROSTATICALLY TESTED AND, WHEN APPLICABLE,
THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO
wrenches are designed to install sprinklers when covers
are in place.
Maintenance
The Models F156 EC and F156 EC Recessed Sprinklers
should be inspected and the sprinkler system maintained
in accordance with NFPA 25. Do not clean sprinklers with
soap and water, ammonia or any other cleaning fluid. Re-
move any sprinkler which has been painted (other than
factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to instal-
lation, sprinklers should be maintained in the original car-
tons and packaging until used to minimize the potential for
damage to sprinklers that would cause improper opera-
tion or non-operation.
Escutcheon Data
Escutcheon
Model Adjustment “A”
Dimension
Face of Fitting
to Ceiling or Wall
Dimension
F1 Max Recessed
Min Recessed
11/2” (38.1mm)
3/4” (19.1mm)
3/16” - 15/16”
(5m - 24mm)
F2 Max Recessed
Min Recessed
11/2” (38.1mm)
1” (25mm)
3/16” - 11/16”
(5m - 17mm)
FP Push-on/
Thread-off
Max Recessed
Min Recessed
7/16” (11mm)
15/16” (24mm)
11/2” (38.1mm)
1” (25mm)
Standard Temperature Rating
Classification
Sprinkler
Temperature
Maximum
Ambient
Temperature
Bulb
Color
°F °C °F °C
Ordinary
Ordinary
135
155
57
68
100
100
38
38
Orange
Red
Maximum Working Pressure
175 psi (12 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Finishes (1)
Standard Finishes
Sprinkler Escutcheon
Bronze
Chrome
White or Black
Polyester Coated(5)
Brass
Chrome
White Painted
Special Applications Finishes
Sprinkler Escutcheon
Electroless Nickel
PTFE(Teflon®)*(5)
Bright Brass(2)
Black Plating
Black Paint
Off White
Satin Chrome
Lead Plated(3)
Wax Coated(3)(4)
Wax Over Lead(3)
Electroless Nickel
PTFE (Teflon®)*
Bright Brass
Black Plating
Black Paint
Off White
Chrome Dull
(1) Other colors and finishes are available on special order. Consult fac-
tory for details.
(2) 200°F (93°C) maximum.
(3) 155°F to 200°F (68°C to 93°C) ratings only.
(4) 286°F (141°C) sprinklers may be coated for ambient conditions not
exceeding 150°F (66°C).
(5) Corrosion Resistant
Note: Paint or any other coating applied over the factory finish will void
approvals and waranties.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Finish (where applicable)
Note: When Model F156 EC Recessed Pendent Sprinklers
are ordered, the sprinklers and escutcheons are
packaged separately.
*DuPont Registered Trademark
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by
Recycled
Paper
Revision lines indicate updated or new data.
EG. Printed in U.S.A. 01/14 P/N 9999970387
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Deluge valves
• Detector check valves
• Check valves
• Electrical systems
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
• Fire department connection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Reliable...For Complete Protection

Other Reliable Irrigation System manuals

Reliable F1-300 User manual

Reliable

Reliable F1-300 User manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable KFR-CCS User manual

Reliable

Reliable KFR-CCS User manual

Reliable F1-28 Series User manual

Reliable

Reliable F1-28 Series User manual

Reliable KFR-CCS User manual

Reliable

Reliable KFR-CCS User manual

Reliable N25 User manual

Reliable

Reliable N25 User manual

Reliable F3QR80 Dry Pendent Operator's manual

Reliable

Reliable F3QR80 Dry Pendent Operator's manual

Reliable F3QR80 Dry Pendent Operator's manual

Reliable

Reliable F3QR80 Dry Pendent Operator's manual

Reliable F1FR QREC Manual

Reliable

Reliable F1FR QREC Manual

Reliable DH80 Dry User manual

Reliable

Reliable DH80 Dry User manual

Reliable F1FR56-300 Series User manual

Reliable

Reliable F1FR56-300 Series User manual

Reliable XL Commercial User manual

Reliable

Reliable XL Commercial User manual

Reliable F1-56-300 Series User manual

Reliable

Reliable F1-56-300 Series User manual

Reliable DH56 HSW-PL User manual

Reliable

Reliable DH56 HSW-PL User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR User manual

Reliable

Reliable F1FR User manual

Reliable F156 Series User manual

Reliable

Reliable F156 Series User manual

Reliable RFC43 User manual

Reliable

Reliable RFC43 User manual

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable DH56 HSW User manual

Reliable

Reliable DH56 HSW User manual

Reliable DH56 HSW-PL User manual

Reliable

Reliable DH56 HSW-PL User manual

Reliable F1FR-FS Series User manual

Reliable

Reliable F1FR-FS Series User manual

Reliable F156 Series User manual

Reliable

Reliable F156 Series User manual

Reliable G6-80 K8.0 User manual

Reliable

Reliable G6-80 K8.0 User manual

Popular Irrigation System manuals by other brands

Blumfeldt 10031357 manual

Blumfeldt

Blumfeldt 10031357 manual

Tyco Fire Product CENTRAL ESFR-25 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL ESFR-25 instruction manual

Eden 96216EDAMZ instructions

Eden

Eden 96216EDAMZ instructions

Autopot easy2grow 80 Set-up guidelines

Autopot

Autopot easy2grow 80 Set-up guidelines

Orbit Voyager II 55072 instructions

Orbit

Orbit Voyager II 55072 instructions

RedMax DA-EX850 Operator's manual

RedMax

RedMax DA-EX850 Operator's manual

Viking VK506 Technical data

Viking

Viking VK506 Technical data

Tyco Fire Product Star PH-2 instruction manual

Tyco Fire Product

Tyco Fire Product Star PH-2 instruction manual

Komet Pivot operating instructions

Komet

Komet Pivot operating instructions

Hunter Professional Series manual

Hunter

Hunter Professional Series manual

HD FIRE PROTECT HD 104 quick start guide

HD FIRE PROTECT

HD FIRE PROTECT HD 104 quick start guide

Netafim MegaNet 15D user manual

Netafim

Netafim MegaNet 15D user manual

AL-KO AQUATROLLEY A 300 manual

AL-KO

AL-KO AQUATROLLEY A 300 manual

Sime SMART quick start guide

Sime

Sime SMART quick start guide

Viking VK1021 Technical data

Viking

Viking VK1021 Technical data

Tyco EC-8 Series quick start guide

Tyco

Tyco EC-8 Series quick start guide

Rain Bird 7005 Operation guide

Rain Bird

Rain Bird 7005 Operation guide

Strongway 49508 owner's manual

Strongway

Strongway 49508 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.