The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F156
Model F1FR56
Intermediate Level
Sprinklers
Features
1. Upright and pendent installations.
2. Available as either a standard response Model
F156 or quick response Model F1FR56.
3. 1/2” (15 mm) orifice with a 1/2” NPT (R
1/2).
Approval Organizations
1. Listed by Underwriters Laboratories, Inc. and Certified
for Canada (cULus)
2. Certified by FM Approvals
UL Listing Category
Sprinklers, Automatic and Open (VNIV)
Product Description
The Reliable Models F156 and F1FR56 Intermediate Level
Sprinklers include shields which protect the glass bulb from
water spray impingement caused by sprinklers located at a
higher elevation.
Typical applications are for storage racks which require
multi–level sprinklers and beneath open grid catwalks.
Application
Model F156 and F1FR56 Intermediate Level sprinklers
are used in fixed fire protection systems: Wet, Dry, Deluge
or Preaction. Care must be exercised that the orifice size,
temperature rating, deflector style and sprinkler type are
in accordance with the latest published standards of the
National Fire Protection Association or the Authority Having
Jurisdiction.
Installation
Model F156 sprinklers are standard response sprinklers
and Model F1FR56 are quick response sprinklers. Both types
are intended for installation as specified in NFPA 13. Upright
sprinklers must be installed with the Model D Sprinkler
Wrench specifically designed by Reliable for use with these
sprinklers and pendent sprinklers must be installed with
the Model GFR2 Sprinkler Wrench specifically designed by
Reliable for use with these sprinklers.
Glass bulb sprinklers have orange covers to protect
the bulb during the installation process. REMOVE THIS
PROTECTION ONLY AFTER THE SYSTEM HAS BEEN
HYDROSTATICALLY TESTED. Model D and GFR2 wrenches
are designed to install sprinklers when covers are in place.
Model F156
Upright Intermediate
Model F1FR56
Pendent Intermediate
Model F1FR56
Upright Intermediate
Model F156
Pendent Intermediate
Maintenance
The Models F156 and F1FR56 Sprinklers should be
inspected and the sprinkler system maintained in accordance
with NFPA 25. Do not clean sprinklers with soap and water,
ammonia or any other cleaning fluid. Remove dust by using a
soft brush or gentle vacuuming. Remove any sprinkler which
has been painted (other than factory applied) or damaged in
any way. A stock of spare sprinklers should be maintained to
allow quick replacement of damaged or operated sprinklers.
Prior to installation, sprinklers should be maintained in the
original cartons and packaging until used to minimize the
potential for damage to sprinklers that would cause improper
or non-operation.
Multilingual document:
Select your language below
Bulletin 031 Rev. C_Multilingual
Bulletin 031 Rev. C_Multilingual
2
013FG01 013FG02
Model F1FR56 Quick Response Upright and Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice Thread Size “K” Factor Sprinkler
Identification
Number (SIN)
Shield Part
Number
Sprinkler
Height Approvals
US Metric
Pendent 1/2” (15 mm) 1/2” NPT (R
1/2) 5.6 80 RA1414 88701411 2.25” 1, 2
Upright 1/2” (15 mm) 1/2” NPT (R
1/2) 5.6 80 RA3195 88701413 2.25” 1, 2
Model F156 Standard Response Upright and Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice Thread Size “K” Factor Sprinkler
Identification
Number (SIN)
Shield Part
Number
Sprinkler
Height Approvals
US Metric
Pendent 1/2” (15 mm) 1/2” NPT (R
1/2) 5.6 80 RA1314 88701411 2.25” 1, 2
Upright 1/2” (15 mm) 1/2” NPT (R
1/2) 5.6 80 RA3125 88701413 2.25” 1, 2
Model F156 and F1FR56 Pendent
Intermediate Level Sprinkler
Model F156 and F1FR56 Upright
Intermediate Level Sprinkler
Fig. 1 Fig. 2
3 1/4” DIA. 3 1/4” DIA.
TO BE ASSEMBLED
AT INSTALLATION
“O” RING
SHIELD
SHIELD
SPRINKLER
ASSEMBLY
SEE TABLE FOR
SPRINKLER
HEIGHT
SEE TABLE FOR
SPRINKLER
HEIGHT
3
Temperature Ratings For F1FR56:
Classification Sprinkler Temperature Bulb Color
°F °C
Ordinary 135 57 Orange
Ordinary 155 68 Red
Intermediate 175 79 Yellow
Intermediate 200 93 Green
High 286 141 Blue
Temperature Ratings For F156:
Classification Sprinkler Temperature Bulb Color
°F °C
Ordinary 135 57 Orange
Ordinary 155 68 Red
Intermediate 175 79 Yellow
Intermediate 200 93 Green
High 286 141 Blue
Extra High 360 182 Mauve
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Temperature Rating
5. Sprinkler Finish
Installation Wrenches
Upright — Model D Sprinkler Wrench
Pendent — Model GFR2 Sprinkler Wrench
Finishes(1)
Standard Finishes
Bronze
Special Application Finishes
Electroless Nickel PTFE(Teflon®)*(4)(5)
Bright Chrome
Chrome Dull
Lead Plated(2)(4)
Wax Coated(2)(3)(4)
Wax Over Lead(2)(3)(4)
(1) Other colors and finishes are available. Consult factory for details.
(2) Model F156 Standard Response only.
(3) 55 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) and 286 °F (141 °C)
temperature ratings only.
(4) Only the sprinkler is wax coated, lead or Electroless Nickel PTFE (Teflon®)*
plated. The shield finish remains galvanized zinc.
(5) cULus listed Corrosion Resistant.
Note: Paint or any other coating applied over the factory
finish will void approvals and warranties.
Shields
Galvanized Zinc
*DuPont Registered Trademark
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by Recycled
Paper
Revision lines indicate updated or new data.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products
manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Reliable... For Complete Protection
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
• Fire department connection
EG. Printed in U.S.A. 01/14 P/N 9999970391

Other manuals for F156 Series

8

This manual suits for next models

1

Other Reliable Irrigation System manuals

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable F3-80 Dry Pendent User manual

Reliable

Reliable F3-80 Dry Pendent User manual

Reliable HL22 Manual

Reliable

Reliable HL22 Manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Reliable DH56 Dry User manual

Reliable

Reliable DH56 Dry User manual

Reliable G VELO Pendent Manual

Reliable

Reliable G VELO Pendent Manual

Reliable GL112 User manual

Reliable

Reliable GL112 User manual

Reliable J112SS Series Manual

Reliable

Reliable J112SS Series Manual

Reliable N252 User manual

Reliable

Reliable N252 User manual

Reliable H PrePak Maintenance manual

Reliable

Reliable H PrePak Maintenance manual

Reliable SWC Manual

Reliable

Reliable SWC Manual

Reliable LT56 Series User manual

Reliable

Reliable LT56 Series User manual

Reliable F1FR56-300 QREC Series Manual

Reliable

Reliable F1FR56-300 QREC Series Manual

Reliable G6-80 Manual

Reliable

Reliable G6-80 Manual

Reliable F1FR 300 QREC Manual

Reliable

Reliable F1FR 300 QREC Manual

Reliable F1FR56 Manual

Reliable

Reliable F1FR56 Manual

Reliable RFC Series Manual

Reliable

Reliable RFC Series Manual

Reliable F1 Res 30 LL User manual

Reliable

Reliable F1 Res 30 LL User manual

Reliable DDX Type D Maintenance manual

Reliable

Reliable DDX Type D Maintenance manual

Reliable F1FR-FS Series User manual

Reliable

Reliable F1FR-FS Series User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable DH56 HSW-PL Manual

Reliable

Reliable DH56 HSW-PL Manual

Reliable F1-28 Series User manual

Reliable

Reliable F1-28 Series User manual

Reliable DH56 HSW-PL User manual

Reliable

Reliable DH56 HSW-PL User manual

Popular Irrigation System manuals by other brands

Tyco DV-5 manual

Tyco

Tyco DV-5 manual

Rain Bird Traveler TR Series Operation guide

Rain Bird

Rain Bird Traveler TR Series Operation guide

Johnson Controls tyco TY-L Series manual

Johnson Controls

Johnson Controls tyco TY-L Series manual

Tyco TY-B Series manual

Tyco

Tyco TY-B Series manual

Lux Tools A-EWSU-C Original instructions

Lux Tools

Lux Tools A-EWSU-C Original instructions

Rain Bird Falcon 6504 Installation and operating guide

Rain Bird

Rain Bird Falcon 6504 Installation and operating guide

PAPILLON 95047 instruction manual

PAPILLON

PAPILLON 95047 instruction manual

Autopot SmartPot 48 XL Set-up guidelines

Autopot

Autopot SmartPot 48 XL Set-up guidelines

WaterGreat SR-1C Installation

WaterGreat

WaterGreat SR-1C Installation

Viking VK532 Technical data

Viking

Viking VK532 Technical data

Viking MIRAGE VK461 Technical data

Viking

Viking MIRAGE VK461 Technical data

CPF SKR15 Installation, Care and Maintenance

CPF

CPF SKR15 Installation, Care and Maintenance

ANC Technology GG-001B user manual

ANC Technology

ANC Technology GG-001B user manual

Toro Infinity Stealth-T installation guide

Toro

Toro Infinity Stealth-T installation guide

CENTRAL tyco CHEC quick start guide

CENTRAL

CENTRAL tyco CHEC quick start guide

Eden WTX-500 Service manual

Eden

Eden WTX-500 Service manual

Trac Vac 330 Operating and assembly manual

Trac Vac

Trac Vac 330 Operating and assembly manual

Autopot easy2grow 48 Set-up guidelines

Autopot

Autopot easy2grow 48 Set-up guidelines

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.